beurer MP 100 Manicure/Pedicure Station Instruction Manual
- June 5, 2024
- Beurer
Table of Contents
beurer MP 100 Manicure/Pedicure Station Instruction Manual
Dear customer,
Thank you for choosing one of our products. Our name stands for high-quality,
thoroughly tested products for applications in the areas of heat, weight,
blood pressure, body temperature, pulse, gentle therapy, massage, beauty, baby
and air.
Please read these instructions for use carefully and keep them for later use,
be sure to make them accessible to other users and observe the notes they
contain. With kind regards, Your Beurer team.
WARNING
- The unit is only intended for domestic/private use, not for commercial use.
- This device may be used by children over the age of 8 and by people with reduced physical, sensory or mental skills or a lack of experience or knowledge, provided that they are supervised or have been instructed on how to use the device safely, and are fully aware of the consequent risks of use.
- Children must not play with the device.
- Cleaning and user maintenance must not be performed by children unless supervised.
- If the mains connection cable of this device is damaged, it must be disposed of.
Included in delivery
1 MP 100 base station
1 MP 100 hand-held device
1 Mains adapter
10 Professional attachments
1 Protective cap for nail dust
30 Single-use attachments made of sandpaper
Intended use
Use the device exclusively to treat hands (manicure) and feet (pedicure).
The device is only intended for the purpose described in these instructions
for use. The manufacturer is not liable for damage resulting from improper or
careless use. The device is suitable for private use, and not for medical or
commercial purposes.
Safety notes
Symbols
The following symbols appear in these instructions
Warning
Warning instruction indicating a risk of injury or damage to health.
Important
Safety note indicating possible damage to the unit/accessory.
Note on important information.
Disposal in accordance with EC Directive WEEE (Waste Electrical and Electronic Equipment)
Important safety notes
Warning
Before using the device, read the safety notes through carefully.
Non-observance of the following information may result in personal injury or
material damage. Store these instructions for use and make them accessible to
other users. Make sure you include these instructions for use when handing
over the device to third parties.
- Check the results regularly during the treatment. It is particularly important for diabetics to do so as they have a lower sensitivity to pain and could injure themselves more easily. The 10 professional attachments supplied with the MP 100 are in principle suitable for diabetics. However, please use with particular care and do not use at high speed. If you have any doubts, consult your doctor.
- This device may only be used for the purpose for which it is designed and in the manner specified in the instructions for use. Any improper use can be dangerous.
- The device may heat up faster when in prolonged, intensive use, for example to sand off calluses on the feet. Allow the device to cool down for a relatively long time between individual applications to prevent skin burns. For your own safety, permanently check the heat development of the device. This applies in particular to persons that are not as sensitive to heat than others.
- Keep the device and mains cable and mains adapter away from water.
- Before use, ensure that the device and accessories show no visible damage. If you have any doubts, do not use the device and contact your retailer or the specified Customer Services address.
- Please check the device frequently for signs of any wear and tear or damage. If there are signs indicating the above or if this device was used improperly, it must be returned to the manufacturer or retailer before further use.
- In the event of defects and operational faults, switch off the device immediately.
- Repairs must only be carried out by Customer Services or authorised suppliers. Never attempt to repair the device yourself! Failure to comply will invalidate the warranty.
- Only use the device with the supplied accessories.
- Always monitor the device when it is in operation.
- Store the device out of the reach of children. The device is not suitable for children.
- Never use the device under a blanket, pillow or cushion, etc.
- Protect the device from impacts, humidity, dirt, chemicals, marked temperature fluctuations and direct sunlight.
- Do not use the device for periods longer than 15 minutes without a pause. After this period, have a break of at least 30 minutes to prevent the motor from overheating.
- Do not use the device while bathing or showering. Do not store the device in areas where it may fall into the bathtub or wash basin.
- Immediately disconnect the mains adapter if the device has fallen into water.
- Never pull the mains adapter out of the socket using the mains cable or with wet hands.
- Do not use the device if it is visibly damaged, does not function properly or if the mains plug or mains adapter is damaged. In these cases, contact Customer Services.
- Attachments may be used by one person only for hygienic reasons.
Getting to know your instrument
The MP 100 manicure and pedicure station is equipped with 10 high-quality and long-lasting professional attachments. The professional attachments have a layer of long lasting sapphire or polishing felt and are therefore ideally suitable for individual treatment and satisfy the highest standards.
Together with the continuously adjustable speed regulation and clockwise/anti clockwise rotation, professional foot and nail care at the standard of a pedicurist is possible. The MP 100 achieves a maximum output of 20,000 rpm and is therefore also suitable for artificial nails.
Unit description
Base station
- Professional attachments
- Protective cap for nail dust
- Clockwise rotation
- Anti-clockwise rotation
- Speed controller
- ON/OFF button
- Hand-held device
- Storage box for professional attachments
- Cover flap for storing the mains adapter
- Hand-held connection
- Mains adapter connection
Hand-held device
- Professional attachment
- Protective cap for nail dust
- Safety lock
Professional attachments
Warning
Take special care when using professional attachments. Improper use, particularly at high speeds, may cause injuries
Sapphire cone, fine
Suitable for removing dry skin, calluses on the sole of the foot and heel, and
treating the nails Do not remove all calluses to maintain natural skin
protection.
Sapphire cone, coarse
Suitable to quickly remove hard skin and large calluses on the sole of the
foot and heel This attachment is intended for application on large areas. Do
not remove all calluses to maintain natural skin protection.
Sapphire wheel, fine
Suitable to file and treating nails, fine-grain sapphire wheel.
The special feature of this sapphire wheel is that the internal sanding disc
rotates whereas the external housing does not. This makes it possible to
precisely file nails without the risk of burning the skin with the quickly
rotating wheel.
Sapphire wheel, coarse
Coarse-grain sapphire wheel, suitable for filing and treating nails. This
attachment makes it possible to cut even thick nails. However, also take care
during use as it quickly removes large areas of the nail.
Cylindrical cutter
Suitable for buffing rough surfaces and coarse smoothing of toenails. For this
purpose, place the cylindrical cutter horizontally on the nail surface and
remove the nail layer by moving the device in slow circles.
Flame-shape cutter
Suitable for removing ingrowing nails For this purpose, carefully position the
flame-shape cutter on the area to be treated and remove the necessary nail
parts.
Sapphire cutter, round
Suitable for carefully removing corns. If you are using this attachment,
please keep in mind that you may penetrate deeper into the skin when removing
the skin layers of the corn, therefore damaging the periosteum.
Nail cutter
Suitable for exposing ingrown nails and cutting dead nail parts. Operate the
nail cutter at a low speed.
Felt cone
Suitable for smoothing and buffing the tips of nails after filing and for
cleaning the surface of nails. Always move the device in circles and never
keep the felt cone in one position as friction may cause heat.
Attachment for using the sandpaper attachments
Suitable for fitting sandpaper attachments.
Sandpaper attachment
Suitable for removing dry skin, calluses on the sole of the foot and heel, and
treating the nails The special feature of the single-use sandpaper attachments
is that they can be removed and disposed of after a single use. 30 single-use
attachments are included in the scope of delivery. Do not remove all calluses
to maintain natural skin protection.
Protective cap for nail dust
Prevents nail dust from escaping.
Initial use
- Check to ensure that the package contains all the parts that should be included in the delivery. If any parts are missing or damaged, contact Customer Services.
- Remove all packaging material.
Warning
Keep packaging material away from children! Choking hazard.
- Place the device on a firm, level and dry surface.
- Connect the mains lead of the mains adapter with the mains adapter connection on the base station
Inserting a professional attachment
-
Turn the safety lock to the open position and carefully push the selected professional attachment onto the hand-held device, up to the stop.
-
To lock the professional attachment in place, carefully turn the sealing ring onto the closed position .
-
Attach the protective cap for nail dust to the tip of the hand-held device from the top.
-
Connect the hand-held device cable to the hand-held connection on the base station.
Important
Make sure the speed controller is set to the lowest setting before connecting the mains adapter to the mains electricity. -
Insert the mains adapter into the socket.
Operation
Warning
Check the results during the treatment. This applies in particular for diabetics as they have less sensitive hands and feet. Stop treatment as soon as it becomes unpleasant.
Important
Ensure the axle can always rotate freely. Do not permanently block the axle as otherwise the device may become hot and damage.
When filing, always move from the outside of the nail towards the tip! Please observe that professional attachments show reduced performance on soaked or wet skin. For this reason, we recommend that you do not soak the foot in water before treatment.
-
Press the ON/OFF button to start treatment.
If the safety lock is not turned to the closed position, the device cannot be switched on. -
Select the desired speed using the speed controller.
-
Select the desired direction of rotation using the buttons for clockwise and anti-clockwise rotation.
-
Do not press too hard and always carefully move the attachments towards the area to be treated. Move the device towards the area to be treated and apply slight pressure while slowly moving the device in circles.
If a large amount of pressure is placed on the rotating attachment, the device automatically switches off. Press the ON/OFF button again to switch the device back on. -
Apply moisturiser to the treated areas after each use.
Cleaning
Warning
Before beginning cleaning, always pull the mains adapter out of the socket!
- Clean the base station and the hand-held device with a damp cloth. If it is very dirty, you can also moisten the cloth with a mild soapy solution.
- For hygienic reasons, you may use alcohol and a cloth or brush to clean the attachments. Allow the attachments to dry afterwards.
- Do not use any chemical or abrasive cleaning agents.
- Ensure that no water enters the device. If this should happen, reuse the device only when it has fully dried out.
- Do not submerge the base station and mains adapter in water or any other fluids.
What if there are problems?
Problem | Possible cause | Solution |
---|---|---|
Hand-held device will not switch on. | Mains adapter not plugged in | Insert the |
mains adapter into the socket.
No voltage at mains socket| Check your fusebox.
Hand-held device not connected to base station.| Connect the hand-held device
to the base station.
Replacement parts and wearing parts
Replacement parts and wearing parts are available from the corresponding listed service address under the stated material number.
Replacement part | Material number |
---|---|
Fine sapphire cone | 163.301 |
Coarse sapphire cone | 163.302 |
Felt cone | 163.303 |
sapphire wheel (fine) | 163.304 |
Sapphire wheel, coarse | 163.305 |
Cylindrical cutter | 163.306 |
Flame-shape cutter | 163.307 |
Sapphire cutter, round | 163.308 |
Nail cutter | 163.309 |
Sandpaper attachment | 163.310 |
Single-use attachments, 30 units | 163.311 |
Protective cap for nail dust | 163.312 |
Mains adapter | 163.313 |
Disposal
Observe the local regulations for material disposal. Please dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment). If you have any queries, please contact the appropriate local authorities
Technical Data
- Model no. MP 100
- Speed Up to 20,000 rpm
- Power supply
Input :100 – 240 V AC, 50/60 Hz, 1.2 A
Output: 15 V DC, 2.3 A
BEURER GmbH • Söflinger Str. 218 • 89077 Ulm (Germany)
Tel.: +49 (0)731 / 39 89-144
Fax: +49 (0)731 / 39 89-255
www.beurer.com
Mail: kd@beurer.de
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>