PHILIPS FC6150-01 Bagless White Handheld Vacuum User Manual

June 5, 2024
Philips

FC6150-01 Bagless White Handheld Vacuum
User Manual

****|
---|---

PHILIPS FC6150-01 Bagless White Handheld Vacuum - Fig

Important safety information

Read this important information carefully before you use the appliance and its accessories and save it for future reference. The accessories supplied may vary for different products.
Danger
– Never vacuum up flammable substances or hot ashes.
– Never immerse the adapter, the charger, or the appliance in water or any other liquid, nor rinse it under the tap.
Warning
– Only charge the appliance with the adapter supplied.
– Check if the voltage indicated on the adapter corresponds to the local mains voltage before you connect the adapter.
– Do not use the appliance if it is damaged.
– The adapter cannot be replaced. If the adapter is damaged, the appliance must be discarded.
– The adapter contains a transformer. Do not cut off the adapter to replace it with another plug, as this causes a hazardous situation.
– This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
– The plug must be removed from the socket outlet before cleaning or maintaining the appliance.
– Keep product and batteries away from fire and do not expose them to direct sunlight or high temperatures.
– If the product becomes abnormally hot or smelly, changes color, or if charging takes longer than usual, stop using and charging the product and contact Philips.
– Do not place products and their batteries in microwave ovens or on induction cookers.
– Do not open, modify, pierce, damage, or dismantle the product or battery to prevent batteries from heating up or releasing toxic or hazardous substances. Do not short-circuit, overcharge or reverse charge batteries.
– If batteries are damaged or leaking, avoid contact with the skin or eyes. If this occurs, immediately rinse well with water and seek medical care.
Caution
– During charging, the adapter feels warm to the touch. This is normal.
– Always switch off the appliance after use and when you charge it.
– Never block the exhaust air openings during vacuuming.
– Always use the vacuum cleaner with the filter unit assembled.
– Noise level: Lc = 73.5 dB(A).
Electromagnetic fields (EMF)
This Philips appliance complies with all applicable standards and regulations regarding exposure to electromagnetic fields.

Ordering accessories

To buy accessories or spare parts, visit www.philips.com/parts-and- accessories or go to your Philips dealer. You can also contact the Philips Consumer Care Center in your country (see the international warranty leaflet for contact details).

Warranty and support

If you need information or support, please visit www.philips.com/support or read the international warranty leaflet.

Recycling

– This symbol means that electrical products and batteries shall not be disposed of with normal household waste (Fig. 5).
– Follow your country’s rules for the separate collection of electrical products and batteries.
Removal of built-in rechargeable battery
The built-in rechargeable battery must only be removed by a qualified professional when the appliance is discarded. Before removing the battery, make sure that the appliance is disconnected from the wall socket and that the battery is completely empty.
Take any necessary safety precautions when you handle tools to open the appliance and when you dispose of the rechargeable battery.
When you handle batteries, make sure that your hands, the product, and the batteries are dry.
To avoid accidental short-circuiting of batteries after removal, do not let battery terminals come into contact with metal objects (e.g. coins, hairpins, rings). Do not wrap batteries in aluminum foil. Tape battery terminals or put batteries in a plastic bag before you discard them.
Warning: NiHM batteries may explode when exposed to high temperatures or fire.
To remove the rechargeable batteries, follow the instructions below.

  1. Let the appliance run until it stops.
  2. Undo the screws to open the housing of the appliance (Fig. 1).
  3. Remove one housing half and take out the rechargeable batteries (Fig. 2).
  4. Squeeze the crimping caps that connect the wires between the handles of a pair of pliers until the crimping caps come off (Fig. 3).
  5. Put the insulating tape around the bare ends of the blue and red battery wires (Fig. 4).

Caution: Keep the blue and red battery wires away from each other and do not connect them.

Troubleshooting

This chapter summarizes the most common problems you could encounter with the appliance. If you are unable to solve the problem with the information below, visit www.philips.com/support for a list of frequently asked questions, or contact the Consumer Care Center in your country.

Problem

| Possible cause|

Solution

---|---|---
The appliance does not work.| The batteries may be low.| Recharge the batteries.
The charging light does not go on.| You may not have put the adapter in the wall socket properly.| Put the adapter in the wall socket properly.
You may not have inserted the appliance plug into the appliance properly.| Make sure that the appliance plug is inserted into the appliance properly.
The on/off switch may be set to on.| Make sure the appliance is switched off when it is connected to the mains for charging.
The vacuum cleaner does not vacuum properly.

| The dust compartment may not be attached to the appliance properly.| Attach the dust compartment to the appliance properly.

The dust compartment may be full.| Empty the dust compartment.
The filter unit in the dust compartment may be clogged.| Clean both parts of the filter unit.
Dust escapes from the vacuum cleaner.| The dust compartment may be full.| Empty the dust compartment.
The dust compartment may not be attached to the appliance properly.| Attach the dust compartment to the appliance properly.
Perhaps the filter unit is not placed in the dust compartment properly.| Place the filter unit in the dust compartment properly.
The vacuum cleaner does not work properly when one of the attachments is attached to the nozzle.| Check if the attachment is blocked.| If the attachment is blocked, remove the obstruction.
The dust compartment may be full.| Empty the dust compartment.
The filter unit may be clogged.| Clean both parts of the filter unit.
The appliance produces a lot of noise.| There may be solid particles in the dust compartment.|

Empty the dust compartment.

  © 2021 Philips Domestic Appliances Holding B.V.
All rights reserved
3000.065.4600.1 (07/2021)
****> 75 % recycled paper

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals