SEALEVEL SeaLINK DIO-16 Digital Interface Adapter User Manual

June 5, 2024
SEALEVEL

SEALEVEL SeaLINK DIO-16 Digital Interface Adapter -
logo SeaLINK DIO-16 Digital Interface Adapter
User ManualSEALEVEL SeaLINK DIO-16 Digital Interface
Adapter

Introduction

The SeaLINK DIO-16 provides 8 Reed relays that can latch power, data, or other electronic signals for control applications and 8 optically isolated inputs to allow monitoring of off board switch  closures, relays or for any other general purpose monitoring needs. The adapter is USB 1.1 compliant.
The SEALINK DIO-16 is designed to be used under Windows 98/ME/2000/XP. The SeaI/O API (Application Programmer Interface) included in Sealevel’s software provides a variety of useful high- level function calls implemented in a Windows dynamic link library (DLL). This API gives access to the SeaLINK DIO-16 I/O from Windows-based platforms such as Visual C++. In addition to the API, SeaI/O includes an ActiveX control along with sample code and utilities to simplify software development.

Other Sealevel USB Digital I/O Products

Model No. Part No. Description
SeaLINK PLC-16 (P/N 8206) – 8 Form C Relays/8 Opto-isolated Inputs
SeaLINK ISO-16 (P/N 8207) – 16 Opto-isolated Inputs
SeaLINK REL-16 (P/N 8208) – 16 Reed Relay Outputs
SeaLINK PIO-48 (P/N 8203) – 48 TTL Inputs/Outputs
SeaLINK PIO-96 (P/N 8205) – 96 TTL Inputs/Outputs

Before You Get Started

What’s Included
The SeaLINK DIO-16 is shipped with the following items. If any of these items are missing or damaged, please contact Sealevel for replacement.

  • SeaLINK DIO-16 Adapter
  • USB A to B Cable, Part# CA179

Advisory Conventions
Warning
The highest level of importance used to stress a condition where damage could result to the product, or the user could suffer serious injury.
Important
The middle level of importance used to highlight information that might not seem obvious or a situation that could cause the product to fail.
Note
The lowest level of importance used to provide background information, additional tips, or other non-critical facts that will not affect the use of the product.

Optional Items
Depending upon your application, you are likely to find one or more of the following items useful for interfacing the SeaLINK DIO-16 to real-world signals. All items can be purchased from our  website (http://www.sealevel.com) or by calling 864-843-4343.

  • DIN Rail Clips (Part Number DR102)
    A pair of brackets, clips, and hardware necessary for DIN rail mounting the SeaLINK DIO-16.

  • 2U 19” Rack Tray (Part Number RK2U)
    Standard 2U rack tray for supporting SeaLINK and other devices.

  • Clamp for Rack Tray (Part Number RK-CLAMP)
    Metal clamp and necessary hardware to secure SeaLINK or other devices to the RK2U rack tray.

  • High Speed USB 2.0 4-Port Hub (Part Number HUB4)
    AC powered 4-port USB hub, AC adapter, and USB cable.

  • High Speed USB 2.0 7-Port Hub (Part Number HUB7)
    AC powered 7-port USB hub, AC adapter, and USB cable.

Software Installation

Windows Installation

Do not connect the SeaLINK DIO-16 adapter to the hose USB device until the software has been fully installed.
Only users running Windows 7 or newer should utilize these instructions for accessing and installing the appropriate driver via Sealevel’s website. If you are utilizing an operating system prior to Windows 7, please contact Sealevel by calling 864.843.4343 or emailing support@sealevel.com to receive access to the legacy driver download and installation instructions.

  1. Select the download for the SeaIO Classic for Windows (Software: SeaIO Classic V5 – Windows – Sealevel.) The setup file will automatically detect the operating environment and install the proper  components. Next (depending on your browser) select the ‘Run this program from its current location’ or ‘Open’ option. Follow the information presented on the screens that follow. During setup,  the user may specify installation directories and other preferred configurations. This program also adds entries to the system registry that are necessary for specifying the operating parameters for  each driver. An uninstall option is also available to remove SeaIO files and registry/INI file entries from the system.
  2. Go to the “Add New Hardware Wizard” in the Control Panel.
  3. When the Wizard asks if you want Windows to search for the new hardware, choose “No, I want to select the hardware from a list.”
  4. Scroll through the list of categorized hardware and select ‘SeaIO Devices.’ If this is the first SeaIO device you may need to select ‘Other Devices’ and ‘Sealevel Systems, Inc.’ instead of ‘SeaIO Devices.’
  5. Click “Next.”
  6. Select the card model and press “Next.”
  7. The Wizard will guide you through a few more informational prompts; continue to click “Next” until it is completed.
  8. Your card’s resource assignments may be adjusted through the Device Manager (if, for instance, you need to change the I/O port address Windows assigned when you installed the card).
  9. Windows software installation is complete

Windows NT is not USB aware and thus cannot support the SeaLINK DIO-16

Physical Installation

The SeaLINK DIO-16 can be installed in any open USB port.
Do not plug the unit into a USB port until the software has been fully installed.

  1. Simply connect the SeaLINK DIO-16 to your USB port with the supplied cable.
  2. The software drivers installed during setup will automatically recognize and configure the device.
  3. You should see one or more “New Hardware Found” windows, indicating the actual device being created.
  4. Next, view your system’s Device Manager.
  5. You should have a new ‘SeaIO 8209’ in the SeaI/O Device heading indicating the installation was successful.

The SeaLINK DIO-16 is now ready for use.

Programming the SeaLINK DIO-16

Sealevel’s SeaI/O software is provided to assist in the development of reliable applications for the Sealevel Systems family of digital I/O adapters. Included in Sealevel’s software are driver functions for  use in accessing the I/O as well as helpful samples and utilities.

Programming for Windows
The SeaI/O API (Application Programmer Interface) provides a variety of useful high-level function calls implemented in a Windows dynamic link library (DLL). The API is defined in the help file (Start/Programs/SeaIO/SeaIO Help) under “Application Programmers Interface.” This help file also includes detailed information dealing with installation / removal of the software and information  about latency, logic states, and device configuration.
For C language programmers we recommend using the API to access the SeaLINK DIO-16. If you are programming in Visual Basic, using the ActiveX control included with SeaI/O is advised.

Samples and Utilities
A variety of sample programs and utilities (both executable and source code) are included with SeaI/O.
Further documentation on these samples can be found by selecting “Start/Programs/SeaIO/Sample Application Description.” Information about where the files are physically stored on your disk is  also included in this same file.

Digital I/O Interface
The SeaLINK DIO-16 provides one parallel input port and one parallel reed relay output port. The ports are organized as ports A, and B. Port A is an input port interfaced to optically isolated inputs,  while port B is the relay output port. The SeaLINK DIO-16 is a line-powered device requiring a USB port capable of sourcing 500 mA.

Serial String
Each device has an eight digit alphanumeric serial string stored in non- volatile memory. On the Windows platforms, this number is used to give each unit a separate identity. This identity allows the  device to be moved to any USB port or hub port on your computer while retaining its device number. If a device becomes damaged and is replaced the new device should be given the same serial string  as the device it is replacing. This string is stored in an EEPROM along with other critical information. This EEPROM is read during enumeration. The device should not be unplugged during its enumeration due to remote  possibility that the data in the EEPROM could be corrupted if power is removed during a read/write cycle to the EEPROM.
Enumeration is complete when the LED is lit.
The control panel utility provides the capability to read or modify this string. However, setting the same string for two units connected to the same computer will cause the second unit to fail  enumeration, and make it invisible to the operating system. Should this occur, unplug one unit, and set the serial string for the other unit to a different string.

Input Port
Port A is an eight bit input port connected to optically isolated input sensors. Each sensor can be used to interface a voltage input and then sense whether the voltage is on or off. Each sensor is isolated  (with respect to a common ground) from every other sensor, and also isolated with respect to the host PC ground. This means that signals such as low-level AC line voltage, motor servo voltage, and  control relay signals can be ‘sensed,’ or read by the PC, without the risk of damage due to ground loops or ground faults.
Each sensor input pair has a current limiting resistor (2.7K ohm) that is used to limit the input current to the opto-isolator. The opto-isolator has two ‘back-to-back’ diodes internally. This allows AC or  DC signals to be sensed, regardless of polarity. When the applied voltage is high enough to cause the led in the opto-isolator to turn-on, the output of the opto-isolator goes low (0 volts), and the signal  is read as a low logic level (binary 0) by the PC. When the input signal is too low to turn on the opto-isolator, the output goes high, and the port bit is read by the PC as a high logic level (binary 1).
The opto-isolator requires approximately 1mA to turn on. The maximum input current is 50mA. There are two things to consider when selecting the input resistor. The first is turn on voltage for the  circuit to sense, and second is the maximum input voltage. Maximum input voltage must not provide too much power to the input resistor and must also not overdrive the opto-isolator input current  specification. The following formulas apply:

Turn on Voltage = diode drop + (turn on current) x (resistance) [Ex: 1.1 + (.003) x R] Input Current = ((input voltage)-1.1V) / (resistor value)
Maximum voltage = 1.1 + square root of (.25(resistor value))

The following table shows the ranges associated with the resistor.

Input Resistor| Turn-On| Input Range| Max Input| Max Current
---|---|---|---|---
2.7KW| 3.0V| 5 – 30V| 37V| 13mA

The turn off voltage for all resistors is less than 1V.

Because through hole resistors are utilized, they cannot be easily replaced. If modification is necessary, Sealevel can do this for an additional charge.
The input circuits are not intended for monitoring 120-volt AC circuits. In addition to being too high a voltage for the circuits, it is dangerous to have that high a voltage on the card.

Output Ports (Reed Relays)
Reed relays provide very high quality, long life, low power, dry contact switch closures. Reed relays are not suited for high current applications, or inductive loads. The relays are normally open, and close  when energized. Writing a logic value of one or zero will change the state. Refer to the Application Programmers Interface for more information.

Pin Assignments (Removable Terminal Block)

Port A Bit Port A Terminals
0 0,1
1 2,3
2 4,5
3 6,7
4 8,9
5 10,11
6 12,13
7 14,15
Port B Bit Port B Terminals
--- ---
0 0,1
1 2,3
2 4,5
3 6,7
4 8,9
5 10,11
6 12,13
7 14,15

Side Panel View Port A

SEALEVEL SeaLINK DIO-16 Digital Interface Adapter - figure
1

Side Panel View Port B

SEALEVEL SeaLINK DIO-16 Digital Interface Adapter - figure
2

Electrical Characteristics

Features

  • 8 SPST Reed relays
  • Eight optically isolated inputs
  • Removable screw terminals
  • Powered by USB port

Specifications

Input Ports

Turn On Current 1mA
Isolator Diode Drop 1.1 VDC
Resistor Power Max .5 W
Maximum Input Range 5 – 30 VDC/VAC

Output Relays

Contact Max Power Rating 10 W
Contact Voltage Maximum 100 VDC/VAC
Contact Current Maximum .5 A AC/DC RMS
Contact Resistance, Initial .15 Ω
Rated Life Low Load: 200 million closures

Maximum Load: 100 million closures
Contact Speed| Operate: .5 mS
Release: .5 mS
Bounce: .5 mS
Maximum Operating Speed| 600 Hz

Temperature Range

Operating 0°C – 70°C
Storage -50°C – 105°C

Power Consumption

Supply line +5 VDC
Rating 500 mA

Manufacturing
All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100% electrically tested.
These printed circuit boards are solder mask over bare copper or solder mask over tin nickel.

Example Circuits

Input Circuit

SEALEVEL SeaLINK DIO-16 Digital Interface Adapter - figure
3

Output Circuit

SEALEVEL SeaLINK DIO-16 Digital Interface Adapter - figure
4

Appendix A–Troubleshooting

The adapter should provide years of trouble-free service. However, in the event that device appears to not be functioning incorrectly, the following tips can eliminate most common problems without  the need to call Technical Support.

  1. Install software first. After installing the software then proceed to adding the hardware. This places the required installation files in the correct locations.
  2. Read this manual thoroughly before attempting to install the adapter in your system.
  3. Use Device Manager under Windows to verify proper installation.
  4. Use the SeaIO Control Panel applet or the Device Manager’s property page for card identification and configuration.

If these steps do not solve your problem, please call Sealevel Systems’ Technical Support, 864-843-4343.
Our technical support is free and available from 8:00 A.M.- 5:00 P.M. Eastern Time Monday through Friday.
For email support contact support@sealevel.com.

Appendix B – How To Get Assistance

Begin by reading through the Troubleshooting Guide in Appendix A. If assistance is still needed please see below.
When calling for technical assistance, please have your user manual and current adapter settings. If possible, please have the adapter installed in a computer ready to run diagnostics.
Sealevel Systems provides an FAQ section on its web site. Please refer to this to answer many common questions. This section can be found at http://www.sealevel.com/faq.asp.
Sealevel Systems maintains a Home page on the Internet. Our home page address is http://www.sealevel.com. The latest software updates, and newest manuals are available via our FTP site that can be  accessed from our home page.
Technical support is available Monday to Friday from 8:00 A.M. to 5:00 P.M. Eastern Time. Technical support can be reached at 864-843-4343.
RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE WILL BE ACCEPTED. AUTHORIZATION CAN BE  OBTAINED BY CALLING SEALEVEL SYSTEMS AND REQUESTING A RETURN MERCHANDISE AUTHORIZATION (RMA) NUMBER.

Appendix C – Silk Screen – 8209 PCB

SEALEVEL SeaLINK DIO-16 Digital Interface Adapter - figure
5

Appendix D–Compliance Notices

Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against  harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance  with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in such case the user will be  required to correct the interference at the users expense.

EMC Directive Statement
Products bearing the CE Label fulfill the requirements of the EMC directive (89/336/EEC) and of the low-voltage directive (73/23/EEC) issued by the European Commission. To obey these  directives, the following European standards must be met:

  • EN55022 Class A – “Limits and methods of measurement of radio interference characteristics of information technology equipment”
  • EN55024 – “Information technology equipment Immunity characteristics Limits and methods of measurement”.

This is a Class A Product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures to prevent or correct the interference.
Always use cabling provided with this product if possible. If no cable is provided or if an alternate cable is required, use high quality shielded cabling to maintain compliance with FCC/EMC directives.

Warranty

Sealevel’s commitment to providing the best I/O solutions is reflected in the Lifetime Warranty that is standard on all Sealevel manufactured I/O products. We are able to offer this warranty due to our  control of manufacturing quality and the historically high reliability of our products in the field. Sealevel products are designed and manufactured at its Liberty, South Carolina facility, allowing direct  control over product development, production, burn- in and testing. Sealevel achieved ISO-9001:2015 certification in 2018.

Warranty Policy
Sealevel Systems, Inc. (hereafter “Sealevel”) warrants that the Product shall conform to and perform in accordance with published technical specifications and shall be free of defects in materials and workmanship for the warranty period. In the event of failure, Sealevel will repair or replace the product at Sealevel’s sole discretion. Failures resulting from misapplication or misuse of the Product,  failure to adhere to any specifications or instructions, or failure resulting from neglect, abuse, accidents, or acts of nature are not covered under this warranty.
Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase.
Customer agrees to ensure the Product or assume the risk of loss or damage in transit, to prepay shipping charges to Sealevel, and to use the original shipping container or equivalent. Warranty is valid  only for original purchaser and is not transferable.
This warranty applies to Sealevel manufactured Product. Product purchased through Sealevel but manufactured by a third party will retain the original manufacturer’s warranty.

Non-Warranty Repair/Retest
Products returned due to damage or misuse and Products retested with no problem found are subject to repair/retest charges. A purchase order or credit card number and authorization must be  provided in order to obtain an RMA (Return Merchandise Authorization) number prior to returning Product.

How to obtain an RMA (Return Merchandise Authorization)
If you need to return a product for warranty or non-warranty repair, you must first obtain an RMA number.
Please contact Sealevel Systems, Inc. Technical Support for assistance:

Available Monday – Friday, 8:00AM to 5:00PM EST
Phone 864-843-4343
Email support@sealevel.com 

Trademarks
Sealevel Systems, Incorporated acknowledges that all trademarks referenced in this manual are the service mark, trademark, or registered trademark of the respective company.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)