Lenovo IBM High IOPS MLC Adapters User Guide
- June 3, 2024
- Lenovo
Table of Contents
IBM High IOPS MLC Adapters
Product Guide (withdrawn product)
The IBM® 365GB, 785GB, and 1.2TB MLC Mono and 2.4TB MLC Duo High IOPS Adapters
for IBM System x®, IBM BladeCenter®, and IBM Flex System™ are second-
generation adapters that come with many of the benefits of standard storage in
addition to the enterprise-class high performance of more than 900,000
sustained input/output operations per second (IOPS). These adapters are
designed primarily for performance-hungry enterprise servers and computing
appliances while providing the added benefits of lower power and cooling
costs, low management impact, and smaller storage footprints.
Figure 1 shows the IBM 2.4TB High IOPS MLC Duo Adapter.
Did you know?
The IBM High IOPS MLC Adapters use flash memory as their storage medium,
contain no moving parts, and do not have issues associated with vibration,
noise, and mechanical failure. The adapters are built as block devices on a
PCIe bus with advanced wear-leveling, advanced ECC, and chip-level redundancy,
providing exceptional reliability and efficiency.
Providing additional peace of mind, these adapters are covered under the IBM
warranty. They carry a 1-year limited warranty, or when installed in a System
x server, these adapters assume your system’s base warranty.
Part number information
Table 1 lists the information for ordering part numbers and feature codes.
Table 1. Ordering part numbers and feature codes
Description | Part number | Feature code |
---|---|---|
IBM 365GB High IOPS MLC Mono Adapter | 46C9078 | A3J3 |
IBM 785GB High IOPS MLC Mono Adapter | 46C9081 | A3J4 |
IBM 1.2TB High IOPS MLC Mono Adapter | 90Y4377 | A3DY |
IBM 2.4TB High IOPS MLC Duo Adapter | 90Y4397 | A3DZ |
IBM 8-pin 3 drop 34.7″ (95cm) Cable | 46C9087 | A3EH |
Note: IBM 8-pin 3-drop 34.7-inch (95cm) Cable (46C9087) is used to support the 2.4TB High IOPS adapter. This cable supplies AUX power required for the x3650 M4 when four or more of the IBM 2.4 TB High IOPS MLC Duo Adapters are installed.
The part numbers for the adapters include the following items:
- IBM High IOPS MLC Mono or Duo Adapter with 3U bracket attached
- 2U bracket loose
- USB Key with documentation
- Quick Install Guide
- Important Notices document
- Warranty Flyer
- Environmental Notices
- IBM Safety Information
- 6-pin 1 drop 16 in. cable (Duo Adapter only)
- 8-pin 3 drop 16 in. cable (Duo Adapter only)
- Solid State Storage Technical Update
Figure 2 shows the IBM High IOPS MLC Mono Adapter (365 GB, 785 GB, or 1.2 TB).
Features
Based on the standard PCIe architecture coupled with silicon-based NAND
clustering storage technology, the High IOPS MLC Adapters are optimized for
System x rack servers and can be deployed in blades through the PCIe expansion
units. These scalable designs come with cost-effective Multi-Level Cell (MLC)
technology in standard PCIe form factors.
These adapters use NAND flash memory as the basic building block of solid-
state storage and contain no moving parts, so they are less sensitive to
issues associated with vibration, noise, and mechanical failure. These
adapters are built as block devices on a PCIe bus with advanced wear-leveling,
ECC, and chip-level redundancy providing unparalleled reliability and
efficiency.
Typical uses are applications with ultra-high performance I/O needs:
- Data-in-memory applications
- Medium to large databases
- Cache
- Video
- Data warehousing
- Business intelligence and analytics
- Decision support
The IBM High IOPS MLC Adapters have the following features:
Technology features:
- Industry-standard PCIe form factors.
- 24 nm NAND flash.
- Cost-effective MLC technology.
- Functions as a PCIe storage and controller device. The operating system sees a block device.
Monitoring and management features:
- Power consumption
- Thermal information
- Flash wear-out
Note: These adapters cannot be used as bootable devices.
Technical specifications
Table 2 presents the technical specifications for the IBM High IOPS MLC
Adapters.
Table 2. IBM High IOPS MLC Adapter technical specifications
Specification | 365 GB | 785 GB | 1.2 TB | 2.4 TB |
---|---|---|---|---|
Part number | 46C9078 | 46C9081 | 90Y4377 | 90Y4397 |
Interface | PCIe 2.0 x8 (x4- wired) | PCIe 2.0 x8 (x4- wired) | PCIe 2.0 x8 (x4- | |
wired) | PCIe 2.0 x8 (x8- wired) | |||
Form factor | Low profile | Low profile | Low profile | Full-height, half-length |
Capacity | 365 GB | 785 GB | 1.2 TB | 2.4 TB |
Endurance | Five-year lifetime expectancy (4 PB TBW) | Five-year lifetime | ||
expectancy (11 PB TBW) | Five-year lifetime expectancy (17 PB TBW) | Five-year |
lifetime expectancy (34 PB TBW)
Data reliability| < 1 in 1020 bits read| < 1 in 1020 bits read| < 1 in 1020
bits read| < 1 in 1020 bits read
Sequential read IOPS| 415,000| 443,000| 445,000| 892,000
Sequential write IOPS| 535,000| 535,000| 535,000| 935,000
Random read IOPS| 137,000| 141,000| 143,000| 285,000
Random write IOPS| 535,000| 535,000| 535,000| 725,000
Sequential read rate†| 910 MBps| 1.5 GBps| 1.5 GBps| 3.0 GBps
Sequential write rate†| 590 MBps| 1.1. GBps| 1.3 GBps| 2.5 GBps
Read access latency| 68 ?s| 68 ?s| 68 ?s| 68 ?s
Write access latency| 15 ?s| 15 ?s| 15 ?s| 15 ?s
Power requirements| 24 W| 24 W| 24 W| 55 W
- 512 bytes block transfers
† 1 MB block transfers The TBW value assigned to a solid-state device is the total bytes of written data (based on the number of P/E cycles) that a device can be guaranteed to complete (the percentage of remaining P/E cycles is equal to the percentage of remaining TBW). The IBM warranty for the solid-state storage is limited to devices that have not reached the maximum guaranteed number of program/erase cycles. Solid-state storage that reaches this limit might fail to operate according to its specifications. Because of such behavior by solid-state devices, careful planning must be done to use solid- state storage in the application environments to ensure that the TBW of the device is not exceeded before the end of the required life expectancy.
Supported servers
The IBM High IOPS MLC Adapters can be installed in the System x and IBM
iDataPlex® servers identified in Table 3 and the BladeCenter and Flex System
servers identified in Table 4.
Table 3. Supported System x and iDataPlex servers (Part 1)
Table 3. Supported System x and iDataPlex servers (Part 2)
Table 4. Supported BladeCenter and Flex System servers
† The HS23, HS23E, and HX5 support these adapters with the addition of the IBM BladeCenter PCI Express Gen 2 Expansion Blade II, part number 68Y7484.
- The x220 and x240 support these adapters with the addition of the IBM Flex System PCIe Expansion Node, part number 81Y8983.
See the IBM ServerProven® website for the latest compatibility information for System x, BladeCenter,iDataPlex, and Flex System servers at http://ibm.com/servers/eserver/serverproven/compat/us/.
Supported operating systems
The IBM High IOPS MLC Adapters support the following operating systems:
- Microsoft Windows Server 2008 R2
- Microsoft Windows Server 2008, Enterprise x64 Edition
- Microsoft Windows Server 2008, Standard x64 Edition
- Red Hat Enterprise Linux 6 Server x64 Edition
- Red Hat Enterprise Linux 5 Server x64 Edition
- SUSE Linux Enterprise Server 11 for AMD64/EM64T
- SUSE Linux Enterprise Server 10 for AMD64/EM64T
- VMware vSphere 5
- VMware ESX 4.1
- VMware ESXi 4.1
See the IBM ServerProven website for the latest information about the specific versions and service packs supported at http://ibm.com/servers/eserver/serverproven/compat/us/. Click System x servers, then Disk controllers to see the support matrix. Click the check mark that is associated with the System x server in question to see the details of the operating system support.
Warranty
The IBM High IOPS MLC Adapters carry a 1-year, customer-replaceable unit (CRU) limited warranty. When installed in a System x server, these adapters assume your system’s base warranty and any IBM ServicePac® upgrade.
Physical specifications
The IBM 365GB, 785GB, and 1.2TB High IOPS MLC Mono Adapters have the following physical specifications:
Dimensions and weight (approximate):
- Height: 16 mm (0.6 in.)
- Width: 70 mm (2.8 in.)
- Depth: 168 mm (6.6 in.)
- Weight: 138 g (0.3 lb)
Shipping dimensions and weight (approximate):
- Height: 124 mm (4.9 in.)
- Width: 19 mm (0.8 in.)
- Depth: 178 mm (7.0 in.)
- Weight: 173 g (0.4 lb)
The IBM 2.4TB High IOPS MLC Duo Adapter has the following physical
specifications:
Dimensions and weight (approximate):
- Height: 16 mm (0.6 in.)
- Width: 110 mm (4.3 in.)
- Depth: 170 mm (6.7 in.)
- Weight: 279 g (0.6 lb)
Shipping dimensions and weight (approximate):
- Height: 149 mm (5.9 in.)
- Width: 19 mm (0.8 in.)
- Depth: 178 mm (7.0 in.)
- Weight: 312 g (0.7 lb)
Operating environment
The IBM High IOPS MLC Adapters are supported in the following environment:
- Temperature (operational): 0 – 55 °C (32 – 131 °F) at 0 – 3,048 m (0 – 10,000 ft); derated by 1 °C per 1,000 ft elevation above sea level
- Temperature (non-operational): -40 – 70 °C (-40 – 158 °F) at 0 – 9,144 m (0 – 30,000 ft); derated by 1 °C per 1,000 ft elevation above sea level
- Relative humidity: 5 – 95% (non-condensing)
- Maximum altitude (operational): 3,048 m (10,000 ft)
Agency approvals
The IBM High IOPS MLC Adapters have the following agency approvals:
- United States FCC 47, Part 15, Subpart B, Class A
- Canada ICES-003, Class A
- Japan VCCI, Class A
- Australia/New Zealand C-Tick-CISPR 22:2009, Class A
- Taiwan BSMI – CNS 13438, Class A
- CE Mark (EN55022, EN55024, EN61000-3-2, EN61000-3-3)
- Korea KN22, KN24, Class A
- Low Voltage Directive IEC/EN 60950-1:2006
Related publications
For more information, see the following documents:
-
IBM US Announcement Letter for IBM 1.2TB and 2.4TB High IOPS MLC Adapters:
http://ibm.com/common/ssi/cgi- bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS112-128 -
IBM US Announcement Letter for IBM 365GB and 785GB High IOPS MLC Adapters:
http://ibm.com/common/ssi/cgi- bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS112-187 -
IBM System x Configuration and Options Guide :
http://www.ibm.com/support/docview.wss?uid=psg1SCOD-3ZVQ5W -
IBM ServerProven:
http://ibm.com/servers/eserver/serverproven/compat/us/
Related product families
Product families related to this document are the following:
- PCIe Flash Adapters
Notices
Lenovo may not offer the products, services, or features discussed in this
document in all countries. Consult your local Lenovo representative for
information on the products and services currently available in your area. Any
reference to a Lenovo product, program, or service is not intended to state or
imply that only the Lenovo product, program, or service may be used. Any
functionally equivalent product, program, or service that does not infringe
any Lenovo intellectual property rights may be used instead. However, it is
the user’s responsibility to evaluate and verify the operation of any other
product, program, or service. Lenovo may have patents or pending patent
applications covering the subject matter described in this document. The
furnishing of this document does not give you any license to these patents.
You can send license inquiries, in writing, to:
Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE. Some
jurisdictions do not allow disclaimers of express or implied warranties in
certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. Lenovo may make improvements
and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.
The products described in this document are not intended for use in
implantation or other life support applications where malfunction may result
in injury or death to persons. The information contained in this document does
not affect or change Lenovo product specifications or warranties. Nothing in
this document shall operate as an express or implied license or indemnity
under the intellectual property rights of Lenovo or third parties. All
information contained in this document was obtained in specific environments
and is presented as an illustration. The result obtained in other operating
environments may vary. Lenovo may use or distribute any of the information you
supply in any way it believes appropriate without incurring any obligation to
you.
Any references in this publication to non-Lenovo Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those Web
sites. The materials at those Web sites are not part of the materials for this
Lenovo product, and use of those Web sites is at your own risk. Any
performance data contained herein was determined in a controlled environment.
Therefore, the result obtained in other operating environments may vary
significantly. Some measurements may have been made on development-level
systems and there is no guarantee that these measurements will be the same on
generally available systems. Furthermore, some measurements may have been
estimated through extrapolation. Actual results may vary. Users of this
document should verify the applicable data for their specific environment.
© Copyright Lenovo 2022. All rights reserved.
This document, TIPS0907, was created or updated on October 16, 2012.
Send us your comments in one of the following ways:
-
Use the online Contact us review form found at:
https://lenovopress.lenovo.com/TIPS0907 -
Send your comments in an e-mail to:
comments@lenovopress.com
This document is available online at https://lenovopress.lenovo.com/TIPS0907.
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other
countries, or both:
Lenovo®
BladeCenter®
Flex System
ServerProven®
System x®
iDataPlex®
The following terms are trademarks of other companies:
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft
Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of
others.
IBM High IOPS MLC Adapters (withdrawn product)
References
- Enterprise Business Server Solutions | IBM
- PCIe Flash Adapters > Lenovo Press
- IBM High IOPS MLC Adapters Product Guide (withdrawn product) > Lenovo Press
- Copyright and Trademark Information | Lenovo US | Lenovo US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>