KABOLA 62-004 Hot Air Heater Instruction Manual

June 5, 2024
KABOLA

KABOLA 62-004 Hot Air Heater Instruction Manual
KABOLA 62-004 Hot Air Heater

INSTALLATION OF A HOT AIR HEATING

Kabola has developed a system where it is not necessary to heat with radiators, but by means of hot air In addition to the simple and. space-saving installation options, our system is unique. Unique because:

  • The system is filled with water; this makes it possible to combine it with radiators.
  • Air heater will only blow when the water temperature is above 60 ° C on position 2B and 3.
  • Unique functions of the control panel:
  1. Manual heating:
    Control the fan speed yourself

  2. B. Semi-automatic:
    When the desired temperature is reached, the hot air fans switch to the lowest setting, but continue to run.
    The boiler switches on and off at the boiler temperature.

  3. Fully automatic, modulating mode:
    Heating with automatic fan speed.
    When the desired temperature is reached, the hot air fans and the Kabola switch off.

Modulating effect:

The fan speed is built up slowly when there is a heat demand. When the desired temperature is reached, the speed decreases and turns off. At the desired temperature, the fan will operate at a very low setting. This gives you a pleasant climate quickly and quietly.

TECHNICAL FACTS AND PARTS

Our system works in a unique way, making it very efficient and taking up little space, so it is possible to choose the most suitable solution for any space.

  • Modulating control panel
  • Whisper quiet
  • Powerful
  • Super efficient
  • Lightweight
  • Space-saving
  • Fully automatic
  • Quickly a pleasant climate
  • Ease of use
  • Ease of installation
  • Long service life
  • Sustainable investment
  • Water-filled

Air outlet straight fixed grill 62-106

Air outlet straight 62-006

Air outlet 45° 62-007

Air outlet 90° 62-008

Control Panel 62-004
TECHNICAL FACTS AND PARTS
TECHNICAL FACTS AND PARTS

Air Heater
TECHNICAL FACTS AND PARTS

Air outlet nozzles

The various connection angles of the outlet nozzles make installation even easier and prevent the air hose from being bended too sharp, when connecting to the outlet nozzle.
Recommended sawing size between 75.9 and 76.8 mm. Preferably use a hole saw 76 mm

Technical properties 4kW – 2 air vents 4kW – 3 air vents
Article number 12V air heater 62-204 62-016
Article number 24V air heater 62-202 62-002
Heating capacity 4 kW 4 kW
Airflow capacity 180 m3 180 m3/h
Power consumption fan 12V/24V 2,5 A / 1,5 A 2,5 A / 1,5 A
Water pipe connection 16 mm 15 mm
Weight 1,7 kg 1,9 kg
Dimensions ventilation motor 125 mm (H) 125 mm (H)
Dimensions air box 110 x 220 x 210 mm (HxWxD) 110 x 260 x 210 mm (HxWxD)
Article number Description Diameter hose

nozzles](https://manuals.plus/wp-content/uploads/2022/05/123-2-550x413.png)
---|---|---|---|---
62-020| Insulated hose, roll 10m| 45 mm| 10 meters
62-021| Insulated hose, roll 20m| 45 mm| 20 meters
62-022| Insulated hose, roll 30m| 45 mm| 30 meters

CLEAN, ECONOMICAL AND QUIET INSTALLATIONS FOR CONTINUOUS USE

INSTALLATIONS

  1. Kabola heating
    (KB Ecoline Hybrid)

  2. Damper

  3. Stainless steel flexible

  4. Fuel line

  5. Fuel tank

  6. Central heating supply

  7. CH return

  8. Air heater

  9. Air hose

  10. Air outlet grilles

  11. Control panel

  12. Towel radiator

  13. Hot water shower

Our hot air heating is extremely suitable for continuous use. Extend your sailing season with Kabola!

MODULATING HOT AIR HEATING OF KABOLA

The control knob has the following functions:

  • Rotate; This adjusts the temperature or fan speed
  • Short press; switches from manual (A) to automatic (B) or vice versa
  • Long press; switches from menu to menu

ATTENTION! To activate menu 3, long press the button from menu 2B. Therefore you must navigate first to menu 2B to be able to access menu 3 afterwards. The lowest temperature of the hot air is 16° C and the LOW position is 6° C frost-free.

Modulating effect:

The fan speed is built up slowly, when there is a heat demand. When the desired temperature is reached, the speed decreases. At the desired temperature, the fan will operate at a very low speed. This gives you a pleasant climate quickly and quietly.

Kabola Heating Systems B.V.

Placotiweg 1E
4131 NL Vianen
Netherlands
+31 (0)347 320 030
info@kabola.nl
www.kabola.nl

Description

1-A| Manual ventilation
Manually adapt the speed of the blower| MODULATING HOT AIR HEATING OF
KABOLA
---|---|---
1-B| Ventilation with temperature control
Automatic ventilation based on temperature setting| MODULATING HOT AIR
HEATING OF KABOLA
2-A| Manual heating
Self control over the fan speed| MODULATING HOT AIR HEATING OF
KABOLA
2-B| Half automatic
When the desired temperature is reached, the hot air fans switch to the lowest setting, but keep running (it can get warmer). The boiler switches on and off on the boiler thermostat.| MODULATING HOT AIR HEATING OF
KABOLA
3| Full automatic modulating position
Heating with automatic fan speed. When the desired temperature is reached, the hot air fans and Kabola switch off, if necessary. It stays at the desired temperature| MODULATING HOT AIR HEATING OF KABOLA

Kabola Heating Systems B.V.
Placotiweg 1E
4131 NL Vianen
Netherlands
+31 (0)347 320 030
info@kabola.nl
www.kabola.nl

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals