GFA KE 9.24 WS-2540 Elektromat Chair Drive Instruction Manual
- June 5, 2024
- GFA
Table of Contents
- GFA KE 120.24-5500 Elektromat Safedrive
- General safety information
- Technical data
- Mechanical installation
- Installation
- Electrical installation
- Limit switch setting
- Motor connection
- Emergency manual operation (hand chain operator)
- Completing commissioning / inspection
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GFA KE 120.24-5500 Elektromat Safedrive
General safety information
Specified use
The drive unit is intended for vertically moving doors. The force is
transmitted using a chain. Doors that must be secured against dropping require
a separate safety brake. The drive unit must be protected against moisture and
aggressive environmental conditions (such as corrosive substances). The drive
units are only suitable for indoor use. Appropriate protective measures must
be taken for outdoor installation. The drive unit is not intended for
hazardous areas. The values specified in the technical data of the drive unit
must not be exceeded. The safe operation can only be ensured if used as
specified.
Target audience of these installation instructions
These installation instructions are geared towards qualified persons trained
in the handling of door systems. Expert knowledge, relevant skills and
practical experience are what set apart qualified persons. They are capable of
safely carrying out the tasks involving installation, maintenance and
modernisation according to the instructions.
Safe operation
The safe operation of the product can only be ensured if it is used as
specified. Follow the installation instructions. Observe all specifications,
especially warnings, when installing the product in the overall system. GfA is
not liable for damage resulting from non-observance of the installation
instructions. The resulting overall system must be reassessed for its safety
in accordance with applicable standards and directives (e.g. CE marking).
These installation instructions refer only to a part of the overall system and
are not sufficient as the sole instructions for the overall system. The
installer of the system must prepare the instructions for the overall system.
We recommend entering the danger area of the system only when the drive unit
is at a standstill.
Warning – Failure to follow these installation instructions may result in severe injury or death.
- Please read these instructions before using the product.
- Keep these instructions handy.
- Include these instructions when passing on the product to third parties.
- Do not let children operate the product unsupervised or use as a toy.
- Allow only competent people to carry out the work.
- Disconnect all cables from the power supply.
- Observe valid regulations and standards.
- Use suitable tools.
- Prevent impermissible forces from acting on the drive unit,
- Check the drive unit for damage if impermissible forces have acted on it. Look even for minor damage. Lock the door during the inspection.
- Contact the service department if you have difficulty assessing the damage.\
Technical data
Designation | Unit | |
---|---|---|
Output speed | 24 | rpm |
Output torque | 1200 (960) 1) | Nm |
Output / hollow shaft | 55,00 | mm |
Series | SG 115 | – |
Limit switch range
(maximum revolutions of the output / hollow shaft)
| 60| –
Supply voltage| 3~ 400| V
Operating current| 6,90| A
Operating frequency| 50| Hz
Power factor cos φ| 0,78| –
Safety circuit| 24| V
Degree of protection| IP 65| –
Temperature range| -10 / +40 (+60) 2)| °C
Operating sound pressure level| < 70| dB(A)
Maximum output speed OPEN / CLOSE
for frequency inverter operation
| 34 / 24| min-1
Cycles per hour| 8 (2,2)1)| h-1
Max. holding torque| 1200| Nm
Braking torque| 20| Nm
Braking voltage| 103-130| V DC
Rectifier type| EGR 230/103| –
Manual force emergency manual operation| 189| N
Mechanical installation
Prerequisites
The permissible loads on walls, fastenings, mountings and transmission
elements must not be exceeded, even for maximum holding torques or locking
torques (▶ refer to technical data).
Connection elements
- Self-locking connection elements with a minimum strength of 800 N/mm2 (8.8) must be used.
- Utilize the hole diameter to the full.
- Use adequately dimensioned washers for elongated holes.
Permissible mounting positions
Transmission elements
- Install the chain wheel properly.
- Position the chain wheels properly.
- Tighten the chain wheel properly.
Mounting
Four elongated holes are provided for mounting. Mount the supplied support
angle on the side of the sprocket.
Installation
The descriptions below apply to general door specifications. The specifications of the door manufacturer must also be observed during installation.
- Thoroughly grease the output-shaft.
- Install (①) and secure (②) the chain wheel. Do not tighten yet. Install (③)and secure (④) the output-shaft on the right or left.
- Mount the drive unit. Tighten the connection elements to 170 Nm.
- Position the chain wheel (①) properly. Install the chain wheel (②). Secure the chain wheel (③).
- Tighten the chain wheel properly (①). Tighten all connection elements (M16) to 170 Nm (②). Install all other connection elements according to the specifications of the door manufacturer.
Electrical installation
Warning – Danger to life from electric current!
- Switch the mains OFF and check that the cables are de-energised
- Observe the applicable regulations and standards
- Make a proper electrical connection
- Use suitable tools
Performing electrical installation
- Remove the cover.
- Insert the motor plug.
- Insert the limit switch plug.
Completing the electrical installation
Limit switch setting
The setting of the final limit positions OPEN and CLOSE is described in the instructions for the door control.
The door control must meet Performance Level c!
Use only door controls that evaluate the limit switch according to EN 12543
and meet Performance Level c. Mount the cable entries and/or cable glands.
Motor connection
Alternative motor connection
Limit switch connection
Emergency manual operation (hand chain operator)
Emergency manual operation is designed for opening or closing the door without power supply. Its activation interrupts the control voltage. Electrical operation is no longer possible.
Warning – Injuries due to incorrect operation!
- Switch off voltage.
- Adopt a secure position.
- For drive units with brake, the emergency manual operation must be carried out against the closed brake.
- Adopt a secure position.
- For drive units with brake, the emergency manual operation must be carried out against the closed brake.
- Do not move the door beyond the final limit positions.
Switch on by pulling the red handle. Open or close by pulling the chain. Switch off by pulling the green handle.
Completing commissioning / inspection
Check the following components and then install all covers.
Gearbox
Check the drive unit for loss of oil (a few drops can be neglected). Protect
the output-shaft permanently against corrosion.
Mounting
Check that all connection elements (consoles, torque mounts, screws, locking
rings, etc.) are secure and in proper condition.
Electrical wiring
Check the connection cables and cabling for damage or crushing. Check that the
screw connections and plug connections are fitted properly with a good
electric contact.
Emergency manual operation
Check the function with the power disconnected. Perform the check only between
the final limit positions.
Limit switch
Check the final limit positions by opening and closing fully. The safety area
must not be approached.
Brake
Warning – Potential injury or danger to life!
- Carry out a brake test. Overrun depends on the door and its equipment. The specifications of the door manufacturer must be observed.
- Brake lift may only be used in the final limit position CLOSE for doors that have no counter-balancing.
- Operation with mains supply after 250.000 cycles
- Operation with Inverter after 1.000.000 cycles
We, GfA ELEKTROMATEN GmbH & Co. KG declare under our sole responsibility that the following product complies with the above directives and is only intended for installation in a door system.
- Drive unit
- KE 120.24-55,00
- Part no.: 10002570 10813
We undertake to transmit in response to a reasoned request by the appropriate
regulatory authorities the special documents on the partly completed
machinery.
This product must only be put into operation when it has been determined that
the complete machine/system in which it has been installed complies with the
provisions of the above-mentioned directives.
The following requirements from Appendix I of the Machinery Directive
2006/42/EC are met: 1.1.2, 1.1.3, 1.1.5, 1.2.2, 1.2.3, 1.2.6, 1.3.2, 1.3.3,
1.3.9, 1.5.1, 1.5.2, 1.5.4, 1.5.6, 1.5.7, 1.5.8, 1.5.9, 1.5.10, 1.5.11,
1.5.13, 1.6.1, 1.6.2, 1.6.4, 1.7.2, 1.7.3, 1.7.4.3.
Standards applied:
- EN 12453:2001
- Industrial, commercial and garage doors and gates – Safety in use of power operated doors – Requirements
- EN 12604:2017
- Industrial, commercial and garage doors and gates – Mechanical aspects – Requirements
- EN 60335-1:2012
- Household and similar electrical appliances – Safety – Part 1: General requirements
- EN 61000-6-2:2005
- Electromagnetic compatibility (EMC) Part 6-2 Generic standards – Immunity standard for industrial environments
- EN 61000-6-3:2007
- Electromagnetic compatibility (EMC) Part 6-3 Generic standards – Emission standard for residential, commercial and light-industrial environments
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>