GfA ELEKTROMATEN 10005161 Safe Drive Motor Instruction Manual

June 5, 2024
GfA ELEKTROMATEN

GfA ELEKTROMATEN 10005161 Safe Drive Motor Instruction Manual

1 General safety information

Specified use

The drive unit is intended for vertically moving doors that need to be secured against dropping. A safety brake is integrated into the gearbox. The drive unit must be mounted directly on the shaft of the door.
The drive unit must be protected against moisture and aggressive environmental conditions (such as corrosive substances). The drive units are only suitable for indoor use. Appropriate protective measures must be taken for outdoor installation. The drive unit is not intended for hazardous areas.
The values specified in the technical data of the drive unit must not be exceeded. The safe operation can only be ensured if used as specified.

Target audience of these installation instructions

These installation instructions are geared towards qualified persons trained in the handling of door systems. Expert knowledge, relevant skills and practical experience are what set
apart qualified persons. They are capable of safely carrying out the tasks involving installation, maintenance and modernisation according to the instructions.

Safe operation

The safe operation of the product can only be ensured if it is used as specified. Follow the installation instructions. Observe all specifications, especially warnings, when installing the product in the overall system. GfA is not liable for damage resulting from non-observance of the installation instructions.
The resulting overall system must be reassessed for its safety in accordance with applicable standards and directives (e.g. CE marking). These installation instructions refer only to a part of the overall system and are not sufficient as the sole instructions for the overall system. The installer of the system must prepare the instructions for the overall system. We recommend entering the danger area of the system only when the drive unit is at a standstill.

Warning – Failure to follow these installation instructions may result in severe injury or death.

  • Please read these instructions before using the product.
  • Keep these instructions handy.
  • Include these instructions when passing on the product to third parties.

Warning – Danger to life from incorrect installation!
Work carried out improperly may result in death or severe injury from electrical current or falling parts.

  • Allow only competent people to carry out the work.
  • Disconnect all cables from the power supply.
  • Observe valid regulations and standards.
  • Use suitable tools.

2 Technical data

Designation   Unit
Output speed 20 rpm
Output torque 250 (250) 1) Nm
Output / hollow shaft 30,00 mm
Series SG 85F

Limit switch range

(maximum revolutions of the output / hollow shaft)

| 20| –
Supply voltage| 1N~ 230| V
Operating current| 7,30| A
Operating frequency| 50/60| Hz
Power factor cos φ| 0,63| –
Safety circuit| 24| V
Degree of protection| IP 65| –
Temperature range| +5 / +40 (+60) 2)| °C
Operating sound pressure level| < 70| dB(A)
Output speed OPEN| 4-20| min-1
Output speed CLOSE| 4-15| min-1
Output speed CLOSE > 2,5 m| 4-15| min-1
Cycles per hour| 12 (8,4)1)| h-1
Max. holding torque| 250| Nm
Locking torque| 635| Nm
Safety brake (testing centre / approval number)| 14-003612-PR03| –
Manual force emergency manual operation| 95| N

3 Integrated safety brake

A safety brake is integrated into the gearbox of this ELEKTROMATEN. The safety brake protects against the door dropping due to breakage or wear of the gear teeth. The safety brake works regardless of the mounting position, speed and rotating direction. It is maintenance-free. The specification of the locking torque and the approval number of the safety brake are available in the technical data of these instructions.

Warning – Danger of the door dropping!
If you need to apply more than the permissible force of 390N (according to DIN EN 12604/DIN EN 12453) to move the door by emergency manual operation, this indicates a stalling on the drive unit or door. Releasing the stalling may cause the door to drop

  •  Adopt a secure position.
  • For drive units with brake, the emergency manual operation must be carried out against the closed brake.

4 Mechanical installation

Prerequisites
The permissible loads on walls, fastenings, mountings and transmission elements must not be exceeded, even for maximum holding torques or locking torques (▶ refer to technical data).

Connection elements

Permissible mounting positions

Mounting

Two elongated holes are provided for mounting.

Installation

The descriptions below apply to general door specifications. The specifications of the door manufacturer must also be observed during installation.

Warning – Potential injury or danger to life!

  • During installation, be sure to use a lifting device that has a sufficient loadcarrying capacity.

▶ Thoroughly grease the door shaft.

▶ Mount the keys.

▶ Attach the drive unit.

▶ Tighten all connection elements (M12) to 75 Nm. Install all other connection elements according to the specifications of the door manufacturer.

5 Electrical installation

Warning – Danger to life from electric current!

  • Switch the mains OFF and check that the cables are de-energised
  • Observe the applicable regulations and standards
  • Make a proper electrical connection
  • Use suitable tools

Performing electrical installation

Completing the electrical installation

Mount the cable entries and/or cable glands.

6 Limit switch setting

The setting of the final limit positions OPEN and CLOSE is described in the instructions for the door control.

The door control must meet Performance Level c!
Use only door controls that evaluate the limit switch according to EN 12543 and meet Performance Level c.

7 Motor connection

M1 Motor
X13 Motor plug

8 Limit switch connection

S10 Emergency manual operation
X12 DES connection

  1. Safety circuit
  2. Channel B (RS485)
  3. Ground
  4. Channel A (RS485)
  5. Safety circuit
  6. Supply voltage W3 Connection cable freqency inverter (FI)

9 Emergency manual operation (hand chain operator)

Emergency manual operation is designed for opening or closing the door without power supply. Its activation interrupts the control voltage. Electrical operation is no longer possible.

Warning – Injuries due to incorrect operation!

  • Switch off voltage.
  • Adopt a secure position.
  • For drive units with brake, the emergency manual operation must be carried out against the closed brake.

Warning – Danger of the door dropping! If you need to apply more than the permissible force of 390N (according to DIN EN 12604/DIN EN 12453) to move the door by emergency manual operation, this
indicates a stalling on the drive unit or door. Releasing the stalling may cause the door to drop.

  • Adopt a secure position.
  • For drive units with brake, the emergency manual operation must be carried out against the closed brake.

Switch on by pulling the red handle. Open or close by pulling the chain. Switch off by pulling the green handle.

10 Completion of commissioning / testing
Check the following components and after that, mount all covers. Gearbox
Check drive unit for oil loss (a few drops are not critical). Protect output shaft permanently against corrosion. Safety brake in the gearbox
The safety brake requires no maintenance or inspection.

Warning – Danger of the door dropping

In the case of a gearbox damage, the internal safety brake is triggered to prevent the door from dropping. The gearbox stalls.
Releasing the stalling may cause the door to drop!

  • Block the door for pedestrians and vehicles.
  • Do not release the stalling. Do not use the emergency manual operation.
  • Secure the door against dropping. Please observe the specifications of the door manufacturer.
  • The drive unit needs replacement. Please observe the specifications of the door manufacturer.

Mounting

Check all mounting elements (consoles, torque brackets, screws, retaining rings etc.) for tightness and impeccable condition.

Electric wiring

Check connection cables and cables for damage or pinches. Check screw and plug connections for correct seating and electrical contact.

Emergency manual operation

Function to be checked in a de-energised state. Carry out functional test only between final limit positions.

Limit switches

Check the final limit positions by opening and closing the door completely. The safety zone must not be reached.

11 Disposal

Dispose of packaging
Dispose of the packaging material properly according to the local legal regulations or recycle it. Dispose of old devices
Dispose of old devices properly according to local legal regulations. Return old devices to the return and collection systems available. You can also return GfA products free of charge. Please apply enough postage to the package and mark it as “old devices”.

Notice- Environmental damage!

The gearbox contains oil.

  • Ensure proper disposal according to local legal regulations.

Declaration of incorporation

within the meaning of Machinery Directive 2006/42/EC for partly completed machinery, Appendix II Part B

Declaration of conformity

within the meaning of EMC Directive 2014/30/EU within the meaning of RoHS Directive 2011/65/EU

We, GfA ELEKTROMATEN GmbH & Co. KG

declare under our sole responsibility that the following product complies with the above directives and is only intended for installation in a door system.Drive unit

SI 25.20 FU-30,00 Part no.: 10005161 10012
We undertake to transmit in response to a reasoned request by the appropriate regulatory authorities the special documents on the partly completed machinery.
This product must only be put into operation when it has been determined that the complete machine/system in which it has been installed complies with the provisions of the above- mentioned directives.
Authorised representative to compile the technical documents is the undersigned.
Düsseldorf, 10.08.2018 Stephan Kleine CEO

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GfA ELEKTROMATEN User Manuals

Related Manuals