ORing IDS-312L Device Server Installation Guide
- June 3, 2024
- ORing
Table of Contents
IDS-312L Device Server
Installation Guide
Introduction
The IDS-312L is an innovative secure one-port RS-232/422/485 to two ports LAN
device server with standard features of device server, such as TCP/IP
interface and versatile operation modes: Virtual Com, Serial Tunnel, TCP
Server, TCP Client, and UDP. In addition, the Windows utility, DS-Tool, could
configure multiple devices and set up the mappings of Virtual Com. On the
other hand, it can simultaneously transfer data up to 5 redundant host PCs to
avoid Ethernet connection breakdown or any host PC failure. Further, IDS-312L
features HTTPS, SSH, and SSL encryption to assure the security of critical
data transmission. The device supports RS-232/422/485 and provides dual
redundant power inputs, 12-48 VDC, on the terminal block to guarantee a non-
stop operation. With wide operating temperature, -10-70°C, and a rugged IP-30
housing design, the device could operate in the harsh industrial environment.
Therefore, IDS-312L is the best solution to the high demand for secure serial
to Ethernet critical data communication.
The product is an open type, intended to be installed in an industrial control
panel or an enclosure.
Package Contents
The device is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance.
Contents | Pictures | Number |
---|---|---|
IDS-312L | X 1 | |
CD | X 1 | |
QIG | X 1 | |
DIN-rail kit | X 1 | |
Wall-Mount Kit | X 2 | |
4-pin terminal block | X 1 | |
Dust cover | X 2 |
Preparation
Before installation, make sure you have all of the package contents available and a PC with Microsoft Internet Explorer 6.0 or later, for using web-based system management tools.
Safety & Warnings
Elevated Operating Ambient: If installed in a closed environment, make
sure the operating ambient temperature is compatible with the maximum ambient
temperature (Tma) specified by the manufacturer.
Reduced Air Flow: Make sure the amount of airflow required for the safe
operation of the equipment is not compromised during installation.
Mechanical Loading: Make sure the mounting of the equipment is not in a
hazardous condition due to uneven mechanical loading.
Circuit Overloading: Consideration should be given to the connection of
the equipment to the supply circuit and the effect that overloading of the
circuits might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing
this concern.
- Indoor use and pollution degree II, it must be wiped with a dry cloth to clean up the device and
- Do not block air ventilation holes.
- If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.”
- Shall be mounted in the Industrial Control Panel and the ambient temperature does not exceed 70 degrees C
DimensionUnit =mm (Tolerance ±0.5mm)
Panel Layouts
Front Panel
- Power status indicators
- LAN connection status indicators
- Serial signal reception status indicator
- Serial signal transmission status indicator
- Dip switch button
- Ethernet port
- Serial port
Rear Panel
- Din-rail screw holes
- Wall-mount screw holes
Installation
DIN-rail
Step 1: Slant the device and screw the Din-rail kit onto the back of the
device, right in the middle of the back panel.
Step 2: Slide the device onto a DIN-rail from the Din-rail kit and make sure
the device clicks into the rail firmly.
Wall-mount
Step 1: Screw the two pieces of wall-mount kits to the top and bottom
panels of the device. A total of eight screws are required, as shown below.
Step 2: Use the device, with wall mount plates attached, as a guide to
mark the correct locations of the four screws.
Step 3: Insert a screw head through the middle of the keyhole-shaped
aperture on the plate, and then slide the device downwards. Tighten the screw
head for added stability.
Network Connection
The device has two 10/100Base-T(X) Ethernet ports. According to the link type,
the AP uses CAT 3. 4, and 5. 5e, 6 UTP cables to connect to any other network
device (PCs. servers. switches, routers. or hubs).
Cable | Type | Max.Length | Connector |
---|---|---|---|
10Base-T | Cat.3,4,5100-ohm | UTP100m(328ft) | RJ45 |
100Base-TX | Cat.5100-ohmUTP | UTP100m(328ft) | RJ45 |
For pin assignments for different types of cables, please refer to the following tables.
10/100 Base-T(X) RJ-45
Pin Number| MDI port| MDI-X port
1| TD+(transmit)| RD+(receive)
2| TD-(transmit)| RD-(receive)
3| RD+(receive)| TD+(transmit)
4| Not used| Not used
5| Not used| Not used
6| RD-(receive)| TD-(transmit)
7| Not used| Not used
8| Not used| Not used
10/100 Base-T(X) RJ-45
Pin Number| Assignment
1| TD+
2| TD-
3| RD+
4| Not used
5| Not used
6| RD-
7| Not used
8| Not used
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair.
DB9 serial port
The device can be connected to a serial device using a DB9 cable. The DB9
connector supports RS232 / RS422 / RS485 operation modes. Please refer to the
following table for the pin assignments of the DB9 connector.
Pin #| RS-232| RS-422| RS-485 (4wire)
RS-485| (2wire)
---|---|---|---|---
1| DCD| TX-| TX-|
2| RXD| TX+| TX+|
3| TXD| RX+| RX+| DATA+
4| DTR| RX-| RX-| DATA-
5| GND| GND| GND| GND
6| DSR| | |
7| RTS| | |
8| CTS| | |
Dip Switch
SW No. | Description |
---|---|
#1 | 150K / 1K Ohm Pull High/Low Resistor |
2
3| Enable / Disable Terminal Resistor
Wiring Power inputs
This device supports dual redundant power supplies, Power Supply 1 (PWR1)
and Power Supply 2 (PWR2). The connectors for PWR1 and PWR2 are located on the
terminal block.
STEP 1: Insert the negative/positive DC wires into the V-/V+ terminals,
respectively.
STEP 2: To keep the DC wires from pulling loose, use a small flat-blade
screwdriver to tighten the wire-clamp screws on the front of the terminal
block connector.
Grounding
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the
ground screws to the grounding surface prior to connecting devices.
Configurations
After installing the device and connecting cables, the green power LED should turn on. Please refer to the following table for LED indication.
LED | Color | Status | Description |
---|---|---|---|
PWR 1/2 | Green | On | The power is on and functions normally |
ETH 1/2 | Green | On | Port is connected |
Blinking | Data Transmitted | ||
RX / TX | Amber | On | Receiving Serial data |
Green | On | Transmitting Serial data |
Follow the steps below to log in and access the system:
-
Launch Internet Explorer and type in the IP address of the device. The default static IP address is 192.168.10.2
-
Log in with the default user name “admin” and password is “admin” also. however, you can set up a password later in the management page. After logging in, you should see the following screen. For more information on configurations, please refer to the user manual. For information on operating the device server using ORing’s DS-Tool management utility, please go to the ORing website.
Contact for maintenance and repair service:
Copyright© 2017 ORing All rights reserved.