ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server Installation Guide

June 3, 2024
ORing

ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server Installation Guide

ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server
Installation Guide

Introduction

IDS-342GT is an innovative secure 4 port RS-232/422/485 to 2 ports Gigabit Ethernet secure device server with standard features of device server, such like TCP/IP interface and versatile operation modes: Virtual Com, Serial Tunnel, TCP Server, TCP Client, and UDP. In addition, the Windows untility, DS-Tool, could configure multiple devices and set up the mappings of Virtual Com. On the other hand, IDS-342GT can simultaneously transfer data up to 5 redundant host PCs to aovid Ethernet connection breakdown or any host PC fails. Further, IDS-342GT features HTTPS, SSH, and SSL encryption to assure the security of critical data transmission. IDS-342GT supports RS-232/422/485 and provides dual redundant power inputs, 12~48 VDC, on terminal block to guarantee a non-stop operation. With wide operating temperature, -40~70oC, and rugged IP-30 housing design, IDS-342GT series could operate in the harsh industrial environment. Therefore, IDS-342GT is the best solution to the high demand of secure serial to Ethernet critical data communication.

Package Contents

The device is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance.

ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server
Installation Guide - Package Contents

Preparation

Before you begin installing the device, make sure you have all of the package contents available and a PC with Microsoft Internet Explorer 6.0 or later, for using web-based system management tools.

Safety & Warnings

⚠ Elevated Operating Ambient: If installed in a closed environment, make sure the operating ambient temperature is compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
⚠ Reduced Air Flow: Make sure the amount of air flow required for safe operation of the equipment is not compromised during installation.
⚠ Mechanical Loading: Make sure the mounting of the equipment is not in a hazardous condition due to uneven mechanical loading.
⚠ Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

Dimension Unit =mm (Tolerance ±0.5mm)

ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server
Installation Guide - Dimension

Panel Layouts

ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server
Installation Guide - Panel Layouts

Installation

Use the mounting kits attached with the package and follow the steps below to install the switch to a rail or to the wall.

DIN-rail Installation

Step 1: Slant the switch and screw the Din-rail kit onto the back of the switch, right in the middle of the back panel.
Step 2: Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch clicks into the rail firmly.

ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server
Installation Guide - DIN-rail Installation

Wall-mounting

Step 1: Screw the wall-mount kit (in the package) onto the back of the switch. A total of six screws are required, as shown below. Step 2: Use the switch, with wall mount plates attached, as a guide to mark the correct locations of the wall-mounting screws. Step 3: Insert a screw head through the large part of the keyhole-shaped aperture on the plate, and then slide the switch downwards. Tighten the screw for added stability.

ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server
Installation Guide - Wall-mounting

⚠ Instead of screwing the screws in all the way, it is advised to leave a space of about 2mm to allow room for sliding the switch between the wall and the screws.

Network Connection

The series have standard Ethernet ports. Depending on the link type, the switch uses CAT 3, 4, 5, 5e UTP cables to connect to network devices (PCs, servers, switches, routers, or hubs). Please refer to the following table for cable specifications.

Cable Types and Specifications:

ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server
Installation Guide - Cable Types and Specifications

For pin assignments for different types of cables, please refer to the following tables.

ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server
Installation Guide - For pin assignments for different types of
cables

DB9 serial port

The device can be connected to a serial device using a DB9 cable. The DB9 connector supports RS232 / RS422 / RS485 operation modes. Please refer to the following table for the pin assignments of the DB9 connector.

ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server
Installation Guide - DB9 serial port

Wiring

Power inputs The device has two sets of DC power inputs on a 6-pin terminal block located on bottom of the device. Follow the steps below to wire the power input on the terminal block.

STEP 1: Insert the negative/positive wires into the V-/V+ terminals, respectively.
STEP 2: To keep the wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the connector.

Configurations

After installing the switch, the green power LED should turn on. Please refer to the following tablet for LED indication.

ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server
Installation Guide - Configurations

Follow the steps to set up the card:

  1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is 192.168.10.2ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server Installation Guide - Launch the Internet Explorer and type in IP address of the switch
  2. Log in with default user name and password (both are admin). After logging in, you should see the following screen. For more information on configurations, please refer to the user manual. For information on operating the device using Oring’s Open-Vision management utility, please go to ORing website.
Resetting

To restore the switch configurations back to the factory defaults, press the Reset button for 5 seconds.

Specifications

ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server
Installation Guide - Specifications ORing IDS-
342GT Industrial Secure Serial Port to Ethernet Device Server Installation
Guide - Specifications

ORing IDS-342GT Industrial Secure Serial Port to Ethernet Device Server
Installation Guide - Certified iconORing Industrial Networking Corp.
TEL: +886-2-2218-1066
Website: www.oringnet.com
FAX: +886-2-2218-1014
E-mail: support@oringnet.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals