MSA Latchways Self Reracting Lifeline SRL Instruction Manual

June 3, 2024
MSA

MSA Latchways Self Reracting Lifeline SRL Instruction Manual

MSA Latchways Self Reracting Lifeline SRL Instruction
Manual

MSAsafety.com

MSA Latchways SRL certificate of conformity

PLACE LOCK TEST STICKER HERE

  1. Serial number: ____

  2. Date of manufacture: dd / mm / yy

  3. We certify that this item has been inspected and conforms to the full requirements and specifications of the relevant standards (tick applicable box):
    ANSI Z359.14-2012
    CSA Z259.2.2-98
    EN 360:2002
    EN 1496: 2006
    IRAM 3605: 2005
    NBR 14628:2010
    The quality control arrangements adopted in respect of this item conforms to the conditions of EN ISO 9001:2008.
    Issue date: dd / mm / yy
    Place: Devizes, UK

  4. Signed/(inspection stamp): _____

MSA Latchways Self Reracting Lifeline SRL Instruction Manual -
Webbing

7 NOTE: 7 m (23ft) Latchways SRL’s use 25 mm (63/64 in) x 2.0 mm (5/64 in) webbing.

No part of this document may be reproduced or transmitted in any form or by any means, without prior permission in writing from

Latchways SRL certificate of conformity

MSA Latchways Self Reracting Lifeline SRL Instruction Manual - Latchways SRL
certificate of conformityinfo.gb@MSAsafety.com
MSAsafety.com

Disclaimer
Every effort has been made to ensure that the information contained within these user instructions is both accurate and current. As part of MSA’s continuous improvement programme changes may be made to the product after the publication date. Therefore, occasionally, the product and these instructions may slightly differ.

Warranty details
MSA warrants the Latchways SRL, excluding auxiliary components, against defects in materials and workmanship. Full terms, conditions and duration can be found at MSAsafety.com/warranty. MSA does not warrant against normal wear and tear, nor damage caused by accident or abuse. If a claim is submitted under warranty, MSA will either repair, replace or refund the Latchways SRL at MSA’s discretion. Warranty benefits are in addition to any statutory rights provided under local consumer legislation.

Date of first use: (page 2) The date the unit is removed from the packaging.
*Date of first use shall be administratively provable. Where the date of first use is unknown, then the next previous administratively provable date shall be used, e.g. date of purchase or date of manufacture.

Periodic examination log (page 144)

To be completed by a Competent person at least every 12 months from the date of first use* and retained. Latchways Sealed Retrieval SRL shall only be examined by Technicians.
Periodic examinations are an important element for maintaining product safety and shall be completed in accordance with MSA instructions. Latchways SRLs scheduled for examination shall be withdrawn from service and tagged “do not use”. Periodic examination instructions may be downloaded from MSAsafety.com. Technicians may repair Latchways SRLs in accordance with MSA’s instructions. For further information contact info.gb@MSAsafety.com.

MSA Latchways Self Reracting Lifeline SRL Instruction Manual - See completed
example below for guidance

Latchways SRL label product markings

MSA Latchways Self Reracting Lifeline SRL Instruction Manual - Latchways SRL
label product markings

Latchways SRL user instructions

The User shall read and understand these user instructions before use and shall follow the user instructions when using the equipment. These instructions and corresponding inspection records shall be retained for future reference and should be used as part of an employee training programme.

It is essential for the safety of the User that if the Latchways SRL is resold outside the original country of destination, the reseller shall provide instructions for use, maintenance, periodic examination and repair in the language of the country in which the device will be used.

Contact MSA if there are any concerns regarding the use, maintenance, applications or operation of this device.
Intended purpose: The Latchways SRL, in accordance with EN/ANSI/CSA/OSHA/ IRAM/NBR standards, is intended to be used as a connecting element within a personal fall arrest system. It must be used vertically in situations where user mobility is required and fall protection is needed. The Mini Latchways SRL is a personal issue item. The MSA Latchways Sealed Retrieval SRL is intended to be used where an integral means of retrieving a casualty is required in the case of a fall, e.g. in confined space environments.

Product limitations: The Latchways SRL shall only be used within it’s limitations and for the purpose for which it is intended. No attempt shall be made to modify or repair the equipment. All instructions shall be followed to ensure the safety of the User. Authorised repairs are to be conducted by a Technician.

  1. Latchways SRLs are for a single user only, only one person can be connected at any time.
  2. Latchways SRLs must be protected from fire, acids, caustic solutions, welding flames, sparks or similar.
  3. Latchways SRLs shall not be used if there is any risk of the device contacting high voltage power lines. This warning also applies to webbing-type devices, as moisture can be absorbed by the lifeline providing a path for electrical current.
  4. Latchways SRLs shall only be used within a cage when a risk assessment has considered the risk of striking the cage during a fall.
  5. MSA Latchways Sealed Retrieval SRL’s retrieval function (where present) is intended for use in lifting a single casualty in an emergency (e.g. following a fall). It must not be used for lifting material or equipment, lifting multiple users or for man-riding purposes.

Personnel requirements: The Latchways SRL shall only be used by a person who is trained and competent in its safe use (see Glossary of Key Terms on page 9). Fitness and age significantly affect a person’s ability to safely withstand fall arrest loads. Only people who are Product capability:

MSA Latchways Self Reracting Lifeline SRL Instruction Manual - Product
capability

physically and mentally fit and healthy, not under the influence of drugs or alcohol, are suitable to use this equipment. Medical advice should be sought if a User’s suitability is unclear. The Latchways SRL shall not be used by pregnant women or minors. A written rescue plan and the means to implement it shall be in place to deal with emergencies that may arise during use.
Anchor point requirements:

MSA Latchways Self Reracting Lifeline SRL Instruction Manual - Anchor point
requirements

System requirements: A fall arrest system comprises of a structural anchor point, full body harness, connector (karabiner/snap hook) and Latchways SRL. All elements in the system shall be used only as specified by the elements manufacturer. It is essential for safety that the anchor device and anchor point shall always be positioned, and work carried out in such a way, to minimise both the potential for a fall and potential fall distance. Note: The Anchor point position shall consider any risks posed by moving machinery and pendulum falls. To ensure positive locking of the Latchways SRL a clear, unobstructed fall path is necessary. Do not use the Latchways SRL when working on materials such as sand or grain, as insufficient fall speed may prevent lock in the event of a fall. It is essential to verify the free space required beneath the User before each use, so that, in the event of a fall there will be no collision with the ground or other obstacle. A minimum of 3 m (10 ft) (including a safety factor of 1 m) from the working level to the nearest obstruction, lower level or ground underneath a hazard should be maintained.

WARNING! Incompatible components can lead to connectors accidentally disengaging. The User shall ensure all connectors are correctly engaged and locked.

  1. Connectors shall conform to EN 362:2004, ANSI Z359.12-2009 and/or CSA Z259.12-11 and be self-closing and self-locking.
  2. A full body harness conforming to EN 361:2002, ANSI Z359.1-2007 and/or CSA Z259.10-12 shall be worn when using the Latchways SRL.
  3. An emergency written rescue plan shall be in place, to be implemented in the event of a fall.

Cleaning, storage and transportation: Clean the Latchways SRL exterior, lifeline and labels (to maintain legibility) with warm water (max. 40ºC/100°F) and non-biological detergent then rinse. An excessive build-up of dirt or paint etc. on the lifeline may compromise the retraction. If the Latchways SRL becomes wet, either from being in use or from cleaning, position the Latchways SRL such that any excess water can drain and leave to dry naturally away from direct heat. The full body harness and any other system components shall be cleaned and stored according to manufacturer’s instructions. Store the Latchways SRL in a cool, dry, clean environment, away from direct sunlight. Examine the Latchways SRL after long periods of storage prior to returning it to service. During transportation the device shall be protected to prevent damage or contamination.

Alterations and additions: No alterations or additions are permitted without MSA’s prior written consent.

Latchways SRL Pre-use checks

Latchways SRLs are designed to be easy to operate and maintain, requiring minimal maintenance and simple pre-use checks. For further information contact info.gb@MSAsafety.com. Operation and use: Attach the Latchways SRL overhead to an anchor point* then complete the Pre- use checks.
Pre-use check by the User:

MSA Latchways Self Reracting Lifeline SRL Instruction Manual - Pre-use check
by the User

Note: If a problem is identified, the Latchways SRL shall be immediately withdrawn from use and cannot be returned to use until examined and recertified by a Technician. Examination, repair and recertification instructions are detailed in a separate document.

Latchways SRL user instructions

When not in use: Do not allow the lifeline to be fully extracted for long periods of time as this may cause weakening of the retraction spring. Do not let go of the lifeline as it will retract at high speed potentially damaging internal parts, causing kinks in the lifeline and/or deploying the load indicating eyelets/snap hooks. If the Latchways SRL is positioned high above the Users head, the use of a tag line is acceptable to allow the Latchways SRL to fully retract and yet enable retrieval of the connector. It is recommended for tag lines to be removed from the device before use.
Do not use an additional lanyard or similar component to lengthen the lifeline.
Do not allow the lifeline to pass through legs or under arms.
Do not use this product for ground level attachments or cable systems.
Do not use over an edge.
Do not allow the lifeline to be in contact with or rub against sharp edges.
Do not allow the lifeline to come into contact with moving machinery.

Webbing lifelines and UV rays: The lifeline may deteriorate when subjected to prolonged periods outside. UV rays can cause the colour of the lifeline to fade and may reduce its strength. If severe discolouration is visible, the lifeline shall be replaced by a Technician.

The service life of a Latchways SRL webbing has been evaluated to be up to 10 years. The following factors such as (but not limited to): environmental conditions (e.g. contact with chemicals, exposure to temperatures >54°C (>130°F)), incorrect storage and frequency of use may reduce service life. If the webbing fails examination, it must be replaced by a Technician. Environmental conditions may affect life expectancy of a galvanised cable. Continued use is dependent upon passing pre-use checks and periodic examinations. Service life may be reduced by frequency and conditions of use or local regulations.

Glossary of key terms
User: A person that has been trained and is competent in the safe use and operation of the Latchways SRL, including the pre-use checks.

Competent person: A person, other than the User, who is competent in the examination of Latchways SRLs, in accordance with MSA’s instructions.

Technician: A person, other than the User, who is trained by MSA to examine, repair and recertify Latchways SRLs, in accordance with MSA’s instructions.

Repair: Replacement of damaged or worn parts by a Technician in accordance with MSA’s instructions.

Periodic examination: Examination completed by a Competent person or Technician at least every 12 months. Local legislation, frequency of use, or environmental conditions (corrosive or chemical environments) may dictate more frequent examination intervals.

MSA Latchways Self Reracting Lifeline SRL Instruction Manual - Fig
D MSA Latchways Self
Reracting Lifeline SRL Instruction Manual - Fig E MSA Latchways Self Reracting Lifeline SRL Instruction
Manual - Fig F-1 MSA
Latchways Self Reracting Lifeline SRL Instruction Manual - Fig
F MSA Latchways Self
Reracting Lifeline SRL Instruction Manual - Fig F MSA Latchways Self Reracting Lifeline SRL Instruction
Manual - Fig G MSA Latchways
Self Reracting Lifeline SRL Instruction Manual - Fig H MSA Latchways Self Reracting Lifeline SRL
Instruction Manual - Fig H MSA Latchways Self Reracting Lifeline SRL Instruction Manual - Fig
I MSA Latchways Self
Reracting Lifeline SRL Instruction Manual - Fig I MSA Latchways Self Reracting Lifeline SRL Instruction
Manual - Fig J MSA Latchways
Self Reracting Lifeline SRL Instruction Manual - Fig J MSA Latchways Self Reracting Lifeline SRL
Instruction Manual - Fig K MSA
Latchways Self Reracting Lifeline SRL Instruction Manual - Fig
L


MSA Latchways Self Reracting Lifeline SRL Instruction Manual - Fig
A MSA Latchways Self
Reracting Lifeline SRL Instruction Manual - Fig A

Latchways plc, An MSA company
Hopton Park, Devizes
Wiltshire, SN10 2JP
United Kingdom
Phone +44 (0)800 066 2222
Email: info.gb@MSAsafety.com
Website: MSAsafety.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals