ionopure Purity Air Sanitizing System Instructions
- June 5, 2024
- ionopure
Table of Contents
Instructions
Product Usage
-
After placing the unit on a flat surface, remove the tank lid and tank, and discard the foam piece in the base.
-
With the cord unplugged, fill the tank with only the amount of ionopure Air Sanitizer needed for one day of use. The sanitizer will lose its potency if it sits in the tank for more than two days.
Note: THE POWER CORD MUST BE UNPLUGGED WHEN FILLING THE TANK. -
Carefully place the tank and tank lid back on the base.
-
Plug the power cord into a grounded power outlet. Make sure the unit’s voltage is correct before use.
-
Turn the “control switch/fog adjustment” button clockwise. Power indicator lights will turn on blue or green. The volume of fog can be adjusted by rotating the switch as the unit begins working.
Note: When the tank level is low, the machine will turn off automatically and the Air Sanitizer shortage indicator light will turn red. Turn off the power switch, unplug the power cord and add ionopure Air Sanitizer to the tank.
Product Components
Product Information
Product Name | Purity Air-Sanitizing System |
---|---|
Model No | Model 001 |
Control Mode | Mechanical Version |
Rated Voltage | 120V |
Rated Frequency | 60 Hz |
Rated Power | 28W |
Tank Capacity | 4.5 L |
Maximum Atomization | 250mL/h |
Product Size (L, W, H) | 180 x 160 x 370mm |
Troubleshooting
Problem | Cause | Solution |
---|---|---|
Sanitizer leaking out of unit | Floating rod may be stuck in the floating rod | |
bracket. | Move the floating rod up and down to help it move freely inside the |
floating rod bracket.
Light on but no fog| Base sanitizer level is too high| Remove some sanitizer
from base and restart unit
Less spray| Mist disc with more scale or excessive impurities in sanitizer|
Clean mist disc or replace sanitizer
Sanitizer does not reach base| Tank cover is dirty or tank is not correctly
installed| Clean tank cover and install tank correctly
Sanitizer in tank exceeds the maximum water level| Reduce sanitizer in tank to
the highest level
Safety Information
Although very rare, in the event eye irritation occurs when using this
product, simply ensure the unit is on low and move the unit farther away from
the affected person. If irritation continues, add 50/50 mixture of cold water
to ionopure Air Sanitizer.
Avoid close, prolonged exposure to sensitive electronics or untreated metals.
DO NOT use on high setting near optical smoke detectors, as they can
mistake the mist for smoke and cause smoke alarms to go off. Setting the unit
on low is sufficient to achieve proper sanitization.
DO NOT run unit in close proximity to clothing, fabrics, upholstery,
carpet, etc. for extended periods, as discoloration may occur in some
materials.
To avoid electric shock, DO NOT unplug product if hands are wet.
DO NOT disassemble, repair or alter product.
When product is in use, DO NOT touch mist disc with hands.
Make sure power cord is not damaged, knotted, clamped or pressed against heavy
objects (this could cause electrical shock, short circuit or fire).
DO NOT replace power cord without authorization. Unplug product
immediately if there are any operational problems and contact manufacturer.
If power supply wiring is damaged, it must be replaced by a professional.
DO NOT remove tank from base when product is in use.
DO NOT touch sanitizer or base parts when product is in use as this is an
electrical device filled with solution. Avoid spilling solution.
This product is only for use indoors.
Unplug product during thunderstorms or if not in use for long periods of time.
DO NOT turn product over during operation. Sanitizer in base could burn
the internal components.
To avoid accidents, DO NOT allow children to use or operate product.
Children should be supervised near the unit at all times. Unplug product when
filling with water and cleaning.
The power supply voltage must be consistent with the rated voltage of the
product. DO NOT use product if supply voltage does not match.
Use unit at the normal room temperature.
Place unit on flat surface to avoid tilting. DO NOT place the unit
directly on a wooden floor.
Place unit at least 2 meters from furniture or electrical appliances to avoid
damage.
Keep away from heat sources and avoid direct sunlight.
If temperature is below 32°F/0°C, pour out the sanitizer in the tank to avoid
damage due to ice.
Turn off power supply and unplug power cord when pouring out sanitizer.
If changing product location, turn off power supply and unplug power cord.
When cleaning, avoid getting water into the internal electronics of product.
Cleaning and Maintenance
The ionopure Purity unit should be cleaned after every 40 hours of use. If the unit is not cleaned on regular basis, sodium can build-up and cause the unit to malfunction.
Simply follow these directions below:
- Unplug the unit before cleaning.
- Rinse the inside of the tank and the lid with warm water. If sodium build-up is severe, white vinegar can be used.
- DO NOT use abrasive objects when cleaning to avoid damage to parts.
- DO NOT use chemical detergents for cleaning. · Always replace old sanitizer in the tank to keep the unit clean and working properly. Sanitizer should not sit in the tank for more than 2 days, or it can lose its potency.
Scale Removal for Transducer and Frame
- Turn off power supply and unplug power cord before cleaning.
- Pour descaling agent into base. Add warm water to dissolve descaling agent and let soak for 5-10 minutes.
- Brush transducer surface with a clean blush until scale is removed.
- Wash the machine seat and the surface of the transducer with clean water.
Warranty Information
With normal use, the ionopure Purity unit has a 6-month warranty from the date of purchase. The following circumstances do not fall within the scope of the warranty:
- Failure to follow the instructions and precautions.
- Fault of product caused by unexpected disasters and other factors such as high voltage, fire, flood, earthquake etc.
- Unauthorized changes, misuse or accidental damage by customer
- Use of product in an unsuitable environment
NOTICE: product and specifications may be updated. The appearance of the actual product may be slightly different.
409 Bearden Park Cir.
Knoxville, TN, USA 37919
www.ionogen.us
Notice: the appearance of the actual product may be slightly different than the product shown in this manual.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>