APC BGM1500B Pro Gaming UPS User Manual
- June 5, 2024
- APC
Table of Contents
- Important Safety Instructions
- Package Contents
- Connect Battery
- Install PowerChute™ Personal Edition Software
- Connect the Equipment
- Operation
- **Alarms and Detected System Errors
- Status Indicators
- Troubleshooting
- Specifications
- Replacement Battery
- Warranty
- FCC Radio Frequency Class B Warning
- Documents / Resources
by schneider Electric
User Manual Back-UPS™ Pro Gaming UPS BGM1500/BGM1500B
Important Safety Instructions
Inspect the package contents upon receipt. Notify the carrier and dealer if
there is any damage.
SAVE THESE INSTRUCTIONS – This manual contains important instructions that
should be followed during installation and maintenance of the UPS nd
batteries.
DANGER
RISK OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
- This UPS is intended for indoor use only.
- Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or humidity.
- Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation.
- Connect the UPS power cable directly to a wall outlet.
Failure to follow these instructions can result in minor or moderate injury and equipment damage.
CAUTION
RISK OF HYDROGEN SULPHIDE GAS AND EXCESSIVE SMOKE
- Replace the battery at least every 5 years or at the end of its service life, whichever is earlier.
- Replace the battery immediately when the UPS indicates battery replacement is necessary
- Replace batteries with the same number and type of batteries as originally installed in the equipment.
- Replace the battery immediately when the UPS indicates a battery overtemperature condition, or when there is evidence of electrolyte leakage. Power off the UPS, unplug it from the AC input, and disconnect the batteries. Do not operate the UPS until the batteries have been replaced.
Failure to follow these instructions can result in minor or moderate injury and equipment damage.
Package Contents
| |
---|---|---
Connect Battery
The UPS is shipped with the battery disconnected.
-
Lay the UPS with the battery door facing up. The arrows point to the locking tabs of the battery compartment.
-
Press the tabs downwards and pull the battery door away from the unit to access the battery modules.
-
Using the handles on both sides of the battery, lift the battery 30 degrees upward to expose the battery connector. Connect the red wire as shown ove.
-
Push the battery into the unit
-
Align the side rails on the cover with the rails on the UPS and slide the cover till it locks in position.
Install PowerChute™ Personal Edition Software
Use PowerChute Personal Edition software to configure the UPS settings. During a power outage, PowerChute will save any open files on your computer nd shut it down. When power is restored, it will restart the computer.
NOTE: PowerChute is only compatible with a Windows operating system. If you are using Mac OSX, use the native shutdown feature to protect your ystem. See thedocumentation provided with your computer.
Installation
Use the USB Data Port Cable supplied with the Back-UPS to connect the data port on the Back-UPS to the USB port on your computer. Download PowerChute ™ Personal Edition Software from www.apc.com/pcpe. Select the appropriate operating system and follow directions to download the software.
Back-UPS Pro Gaming UPS 1500 VA
Connect the Equipment
Battery Backup and Surge Protected outlets
When the Back-UPS is receiving input power, the Battery Backup with Surge
Protection outlets will supply power to connected equipment. During a power
outage or other AC problems, the Battery Backup outlets receive power for a
limited time from the Back-UPS. Connect Gaming PC, Console, router and onitor
to theseoutlets so you could stay on line during power outage.
Connect equipment such as External Hard Drive, Television or other peripherals that do not need battery backup power to the Surge Protection Only utlets. These outlets provide full-time protection from surges even if the Back-UPS is turned off.
1| USB and SerialData Port|
To use PowerChute PersonalEdition, connect the supplied USB
communication cable
---|---|---
2| Ground Screw| Connect the ground lead from an additional surge suppression
device such as a stand-alone data line surge protector.
3| Building Wiring Faul Indicator| If this illuminated, there is a problem
with the wiring in the
building. Contact an electrician immediately and do not use the
Back-UPS.
4| Coaxial Ports withSurge Protection| Connect a cable modem or other
equipment with coaxial jacks.
5| Circuit breaker Reset Button| Use to reset the system after an overload
condition has tripped the circuit breaker interrupt currentflow.
6| Surge Protected Outlets| These outlets provide full-time protection from
surges, even if the Back-UPS is off. Connect equipment such as printers and
scanners that do not require battery backup protection.
7| In/Out Ethernet Surge Protected Ports| Use an Ethernet cable to connect a
cable modem to the in port, and connect a computer to the OUT port.
8| Battery Backup Outlets withSurge Protection| During a power outage or other
AC problems, the Battery Backup receive power for a limited time from the
Back-UPS. Connect essential equipment such as Gaming PC, Console, Router or
other gaming gear into these outlets.
9| Rear LEDs| The Rear LEDs provide 12-color ambient lights to help you add/
remove loads from outlets.
Back-UPS Pro Gaming UPS 1500 VA
Operation
Top Bezel Buttons and Display Interface
Use the four buttons on the front panel of the Back-UPS and the display
interface to configure the Back-UPS.
Front Panel
1 | INFORMATION button |
---|---|
2 | POWER ON/OFF button |
3 | MUTE button |
4 | Display interface |
5 | LED button |
6 | USB charging ports: The 3 USB ports provide a total of 15W of DC |
power, and willprovide power even when the UPS is on battery.
7| Reactor Circle: Provides 12-color ambient lights.
| On Line: The Back-UPS is supplying conditioned Utilitypower to
connected equipment
---|---
| Load Capacity: The approximate load capacity percentage is indicated by
the number of load bar sections illuminated. Each bar represents approx 20% of
load capacity.
****|
Battery Capacity: The battery charge level is indicated by the number of bar sections illuminated. When all five bar sections are illuminated, it indicates that the battery is fully charged. When only one bar section is illuminated, it indicates the battery charge is nearing depletion.
| Low Battery: When the battery charge is completely depleted and the UPS is
nearing shutdown, the indicator will flash accompanied by a continuous beep.
| Replace Battery: The battery is nearing the end of its useful life and
should be replaced immediately.
| On Battery: The UPS is supplying battery power to the connected equipment.
The UPS will emit an audible beep once in every 10 seconds.
|
System Error Detected: A system error has been detected. The system error number will be displayed on the display interface. Refer “Detected system errors” on page 6, for details.
| Overload: The connected equipment is drawing more power than the rated
capacity of the UPS.
---|---
| Mute: An illuminated line through the icon indicates that the audible alarm
is disabled.
| Out: Output voltage, frequency
| In: Input voltage, frequency
| Automatic Voltage Regulation:
| When illuminated, the Back-UPS is compensating for low input voltage.
| When illuminated, the Back-UPS is compensating for high input voltage.
| Estimated Runtime: Indicates the remaining runtime (in minutes) in on-
battery mode.
LOAD
|
Load: The total load in watts (W) or percentage (%) used by the devices indicates the remaining runtime (in minutes) in on-battery mode.Event: The number of events that shows up on the LCD screen are the number of power disturbances that your UPS has detected. These disturbances can be any of the following: blackout, under/over voltage, total harmonic distortion, surge, spike, etc.
Unit sensitivity
The higher the sensitivity, the more often the Back-UPS switches to battery
power. Adjust the sensitivity of the Back-UPS to control when the UPS will
switch over to battery power;
- Turn off the Back-UPS while connected to a wall outlet.
- Press and hold the INFORMATION button for six seconds. The Load capacity icon will flash on and off, indicating that the Back-UPS is in programming mode.
- Press INFORMATION button to navigate through the menu options. Stop at selected sensitivity.
Generator Sensitivity | Default | Sensitive Loads |
---|---|---|
Low sensitivity | Medium sensitivity (Default) | High sensitivity |
--- | --- | --- |
78-150 Vac | 88-147 Vac | 88-144 Vac |
Gaming UPS will change to battery mode only when input voltage is extremely low or high. Not recommended for computer or gaming console loads.
| 1’his is default sensitivity setting and is recommend for Gaming PC and Gaming consoles.|
The connected equipment is sensitive to voltage fluctuations.
**Alarms and Detected System Errors
**
Audible indicators
Overload | Beep every 0.5 second |
---|---|
Low battery | Beep every 0.5 second |
Overcharge | Beep every 1.5 seconds |
Battery replacement | Beep every 2 seconds |
Battery mode | Beep every 30 seconds |
Internal error detected | Continuous beep |
Detected system errors
If the UPS system does not operate correctly, use the table below to resolve the problem.
FOI| Overload fault| Turn the Gaming UPS off. Disconnect non-essential
equipment from the Battery Backup outlets and then turn Gaming UPS on.
---|---|---
F02| Output short| Turn the Gaming UPS off. Disconnect all equipment from the
Battery Backup outlets and then turn Gaming UPS on. Reconnect equipment one
item at a time. If the system error is detected again, disconnect the last
connected equipment as it is in an inoperable condition.
F05| Over Charge Voltage| Contact APC by Schneider Electric support
F06| Relay Welding| Contact APC by Schneider Electric support
F07| Over Temperature or NTC disconnected| Contact APC by Schneider Electric
support
F08| Fan lock error detected.| Contact APC by Schneider Electric support
F12| Battery mode output high.| Contact APC by Schneider Electric support
F13| Battery mode output low| Contact APC by Schneider Electric support
F28| Low battery voltage| Replace the battery. If the detected error still
occurs after battery is replaced, contact APC by Schneider Electric Support
Function| Button| Timing| Description
---|---|---|---
Power On| | 2 seconds| Press and hold the POWER ON/OFF button to turn on UPS.
Power Off| 2 seconds| Press and hold the POWER ON/OFF button to turn off UPS.
Self-Test mode| 6 seconds| Press and hold the POWER ON/OFF button for 6
seconds (buzzer will beep when 6 seconds pass) to go into Self-Test mode when
UPS is in Line mode or AVR mode.
UPS Information| | 0.2 seconds| Press the INFORMATION button to display UPS
information. The information will cycle from Event counter —). Runtime —, Load
watt
Load VA —). Load percentage —■ Output voltage —). Output frequency
Input voltage —> LCD off.
Sensilh If,| 6 seconds| When the UPS is powered off, press and hold the
INFORMATION button, the Load Capacity icon will blink, indicating that the UPS
is in programming mode. Use the INFORMATION button to scroll through Low,
Medium, and High. Stop at selected sensitivity for 5 seconds. The UPS will
beep confirming the selection.
Mute| | 2 seconds| Press and hold the MUTE button to enable or disable the
audible alarms.
LED Color| | 0.2 seconds| Click to LED button to select LED Color (There are
twelve colors to choose from). The front and rear LED will be synced in color.
Previous LED Color| 2 seconds| Press and hold the LED button (till a beep is
heard after 2 seconds) to select previous LED Color
Turn on/off the LED lights| 6 seconds| Press and hold the LED button to turn
on/off the LED lights (buzzer will beep when after 6 seconds pass). The status
will cycle through:
Front and rear LED on —, Front LED on, rear
LED off —> Front LED off, Rear LED on —). Front LED and rear LED off
Event Reset| | 0.2 seconds| When the Event screen is visible, press and hold
INFORMATION button, then press POWER ON/OFF button to clear the detected event
counter.
Status Indicators
Unit Status
|
Description
---|---
Standby| When the unit is plugged into the AC outlet but is turned off, LCD
will display battery capacity, input voltage and mute icon. LED ring will be
in customized color. In standby mode, the connected equipment will not be
protected.
UPS is turning on| All LEDs will light up and the colors will slowly cycle
among all available colors. The process should take about 10 seconds.
Equipment is plugged in| The Reactor circle will show the load percentage. The
Rear LEDs do not change. Rear LEDs will return to idle state after 10 seconds.
Equipment is unplugged| The Reactor circle will show the load percentage. Rear
LEDs do not change. Rear LEDs will return to idle state after 10 seconds.
Idle State| This animation occurs after lOs of inactivity. This occurs every
time except when UPS has detected a system error. Rear LED doesn’t change
(keeps custom/default color).Idle state color is defined by the custom color
that user selects (default white). LED illumination in idle state is always at
60% intensity.
Press a button| The LCD will be lit. The unit will switch to idle state after
10 seconds of inactivity.
Power Outage (unit goes on battery)| The Reactor circle will light up to show
the runtime percentage, and the displayed percentage will reduce as the
runtime reduces. The reactor circle color will be green and blinking if
battery life is above 50%, orange and pulsing when battery life is between 20%
and 50%, red and flashing when battery life is under 20%.
Low Battery| When the unit is on battery and the battery capacity is low (i.e.
when the unit continuously beeps) the reactor circles that is still on will
turn red and pulsing – regardless of the color you have selected. The back-
light will match this functionality – but only when lighting is enabled.
Overload| The reactor circle lights up in red. It will remain in this state
until the unit is no longer overloaded.
Dead Battery| Th e reactor circle lights up in red. It will remain in this
state until the battery is charged or replaced
Building Wiring Fault| The reactor circle lights up in red and pulsing. It
will remain in this state until the building wiring fault is no longer
detected
Power Surge| All LEDs light up in your chosen color
Rear LED has same behavior as reactor circle.
Power Dip
LCD Information| LCD will cycle through different information when INFORMATION
button is
pressed. The information will be cycle from Event counter —> Runtime —>
Load watt —> Load VA —> Load percentage —> Output voltage —>
Output frequency —> Input voltage —> LCD off. |When Runtime is displayed, the
Reactor circle color will be green and blinking if battery life is above 50%,
orange and pulsing when battery life is between 20% and 50%, red and flashing
when battery life is under 20% When Load percentage is displayed, the LED ring
color will be green.
Troubleshooting
Problem | Possible Cause | Corrective Action |
---|---|---|
Back – UPS will not switch on | The Back-UPS is not connected | |
to utility power. | Be sure that the Back-UPS is securely connected to a |
utility outlet.
The circuit breaker has tripped.| Disconnect non-essential equipment from the
Back-UPS. Reset the circuit breaker. Reconnect equipment one item at a time.
If the circuit breaker trips again, disconnect the device that caused the
circuit breaker to trip.
The internal battery is not connected.| Connect the battery.
The input voltage is out of range.| Adjust the transfer voltage and
sensitivity range.
The Back-UPS does not provide power during a utility power outage.|
Be sure that essential equipment is not plugged into a surge only outlet.|
Disconnect equipment from the surge only outlet and re-connect to a Battery
Backup outlet.
The Back – UPS is operating on battery power,
while connected to utility power.| Plug is not inserted fully into the wall
outlet, the wall outlet is no longer receiving utility power, the circuit
breaker has tripped.| Be sure that the plug is fully inserted into the wall
outlet. Be sure that the wall outlet is receiving utility power by checking it
with another device. Reset the circuit breaker
The Back-UPS is performing an automatic self-test.| No action is necessary.
The input voltage is out of range, the frequency is out of range, or the waveform is distorted.
| Adjust the transfer voltage and sensitivity range.
The Back-UPS does not provide the expected amount of backup time.|
Battery Backup outlets may be fully or improperly loaded.| Disconnect non-
essential equipment from the Battery Backup outlets and connect the equipment
to surge outlets.
The battery was recently discharged due to a power outage and has not fully
recharged.| Charge the battery for 16 hours.
The battery has reached the end of its useful life.| Replace the battery.
The Replace Battery indicator is illuminated.| The battery has
reached the end of its useful life.| Replace the battery immediately
The Overload indicator is illuminated.|
The equipment connected to the Back-UPS is drawing more power than the Back-UPS can provide.
|
Disconnect non-essential equipment from the Battery Backup outlets and connect the equipment to surge outlets.
Problem
| Possible Cause|
Corrective Action
---|---|---
The System Error Detected indicator is illuminated, all the front panel
indicators are flashing.| An internal error has been detected.|
Determine the detected system error by matching the detected error number displayed on the LCD with the corresponding detected system error number in “Detected system errors” on page 6. Contact APC by Schneider Electric support.
Mobile phone is not getting charged through the USB port.| The UPS is in
Stand-by mode.| Be sure that the UPS is in On-battery mode or On-line mode.
Charging cable connector is not fully inserted into the USB port.| Be sure
that the charging cable connector is securely inserted into the USB port.
Charging cable is damaged.| Replace the charging cable. If problem persists
even after the charging cable is replaced, contact APC by Schneider Electric
support.
Mobile phone charging standard not compatible.|
Try charging another mobile phone which is compliant with USB charging standard BC1.2. If the problem persists with this mobile phone also, contact APC by Schneider Electric support.
An Internal error has been detected.| Contact APC by Schneider Electric support.
Specifications
Rating | 1500 VA |
---|---|
Maximum Load | 900 W |
Nominal Input Voltage | 120 V |
Online Input Voltage Range | 88 – 147 V |
Automatic Voltage Regulation | Boost by +15.7% when input voltage drops |
below limit
Trim by -13.6% when input voltage exceeds limit
Frequency Range| 60 Hz ± 3 Hz
USB charging port| Type Cs 1, Type A*2 (15 W in total)
Typical Recharge Time| 16 hours
Transfer Time| 8ms (Typical), 10ms (Max)
Operating Temperature| 32 to 104 °C (0 — 40 °C)
Storage Temperature| 23 to 113 °C (-15 to 40 °C)
Unit Dimensions| 16.0 x4.I x11.4 in (408 x105 x291 mm)
Unit Weight| 25.3 lb (11.5 kg)
Color| BGM 1500 – White; BGM1500B – Black
Interface| USB
On-Battery Runtime| Go to: hop:/Avww.apc.com/
International Protection Code| IP20
Replacement Battery
T he battery typically lasts for 3 to 5 years, a shorter period if
subjected to frequent outages or elevated temperatures. Contact APC support
for battery eplacement parts. Battery replacement parts for BGM1500 and
BGM1500B is APCRBC163.
Delaying the replacement of batteries may corrode the batteries in the
cartridge. Recycle spent battery cartridges.
Warranty
The standard warranty is three (3) years from the date of purchase. Schneider Electric IT (SEIT) standard procedure is to replace the original unit with a factoryreconditioned unit. Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare uch a need at first contact with an SEIT Technical Support representative. SEIT will ship thereplacement unit once the defective unit has been received by he repair department, or cross ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to SEIT. SEIT pays ground freight transportation costs to ship the replacement unit to the customer.
APC by Schneider Electric Customer Support
Internet | http://www.apc.com/support |
---|---|
Toll Free | 18001030011/18004194272 |
indiainfo@apc.com |
Select models
are ENERGY STAR
qualified. For more information on your specific model visit the APCby
Schneider Electric web site, www.apc.com.
FCC Radio Frequency Class B Warning
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are esigned to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmfulinterference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
© 2021 APC by Schneider Electric. APC, the APC logo, PowerChute and Back-UPS
are owned by Schneider Electric Industries S.A.S., or their affiliated
ompanies. All other trademarks are property of their respective owners.
990-6266B
03/2021
Documents / Resources
| APC
BGM1500B Pro Gaming
UPS
[pdf] User Manual
BGM1500, BGM1500B, BGM1500B Pro Gaming UPS, BGM1500B, Pro Gaming UPS
---|---
References
- APC, a flagship brand of Schneider Electric - APC USA
- APC, a flagship brand of Schneider Electric - APC USA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>