beurer MP62 Manicure Pedicure set Instruction Manual

June 5, 2024
Beurer

beurer MP62 Manicure Pedicure set

Read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users and observe the information they contain.

WARNING

  • The device is only intended for domestic/private use, not for commercial use.
  • This device may be used by children over the age of 8 and by people with reduced physical, sensory or mental skills or a lack of experience or knowledge, provided that they are supervised or have been instructed on how to use the device safely, and are fully aware of the consequent risks of use.
  • Children must not play with the device.
  • Cleaning and user maintenance must not be performed by children unless supervised.
  • Do not use the device if it shows signs of damage or does not function properly. In these cases, contact Customer Services.
  • Repairs must only be carried out by Customer Services or authorised suppliers.
  • If the mains connection cable of this device is damaged, it must be disposed of. If it cannot be removed, the device must be disposed of.
  • Under no circumstances should you open or repair the device yourself, as faultless functionality can no longer be guaranteed thereafter. Failure to comply will invalidate the warranty.

Dear Customer,
Thank you for choosing a product from our range. Our name stands for highquality, thoroughly tested products for applications in the areas of heat, weight, blood pressure, body temperature, pulse, gentle therapy, massage, beauty, air and baby. With best regards Your BEURER Team

Items included in the package

Check that the device packaging has not been tampered with and make sure that all contents are present. Before use, ensure that there is no visible damage to the device or accessories and that all packaging material has been removed. If you have any doubts, do not use the device and contact your retailer or the specified Customer Services address.

  • 1 x Manicure and pedicure device
  • 10 x High-quality attachments made from sapphire and felt
  • 10 x Single-use attachments made of sandpaper
  • 1 x Adapter
  • 1 x Storage pouch
  • 1 x These instructions for use

Signs and symbols

The following symbols are used in these instructions for use, on the packaging and on the type plate for the device:

WARNING

| Warning notice indicating a risk of injury or damage to health.
---|---

IMPORTANT

| Safety note indicating possible damage to the device/accessory.

Note

| Note on important information.
| Observe the instructions for use
| Disposal in accordance with the Waste Electrical and Electronic Equipment EC Directive – WEEE
| Manufacturer
| The device is double protected and therefore corresponds to protection class 2.
| Only use indoors.
| Dispose of packaging in an environmentally friendly manner
| CE labelling
This product satisfies the requirements of the applicable European and national directives.
| The products demonstrably meet the requirements of the Technical Regulations of the EAEU
| Polarity
| Energy efficiency class 6

Intended use

The device is only intended for the purpose described in these instructions for use. The manufacturer is not liable for damage resulting from improper or careless use.

Warnings and safety notes

IMPORTANT
During use, considerable heat may be experienced on the skin. ­

  • Check the results regularly during the treatment. It is particularly important for diabetics to do so as they have a lower sensitivity to pain and could injure themselves more easily. In principle, the attachments that are supplied with the device are suitable for diabetics.
    However, please use with particular care and do not use at high speed.
    If you have any doubts, consult your doctor.

  • This instrument must be used only for the purpose for which it has been developed, and in the manner described in the instructions for use. Any improper use can be dangerous.

  • In case of prolonged intensive use (e.g. milling of dead skin from your feet) the device might get very hot. In order to prevent skin burns in these situations, there should be longer breaks between each application. For your own safety, constantly monitor heat build up in the device. This particularly applies to people who are insensitive to heat.

  • The device is only for private use and is not intended for medical or commercial purposes.

  • The manager is not responsible for damage or injury caused by improper or incorrect use.

  • The appliance must be checked frequently for signs of wear or damage. If such signs are present, or if the appliance has been used improperly, it must be taken to either the manufacturer or the dealer before further use.

  • Switch off the instrument immediately in the event of defects or malfunctions.

  • Repairs may be carried out only by the customer service or authorized dealers.

  • On no account try to repair the instrument yourself!

  • Use the instrument only with the accessories provided.

  • Never leave the instrument unattended when it is in operation.

  • Keep the instrument away from children to prevent any possible danger.

  • Keep the instrument away from sources of heat.

  • Do not use the instrument under blankets, pillows etc.

  • The instrument must not be operated continuously for longer than 15 minutes.

  • After this time, wait an interval of at least 30 minutes to prevent the motor from overheating.

  • Do not use the instrument when bathing or showering. Do not store or keep the instrument in places from where it could fall into a bath or wash basin.

  • Never immerse the instrument in water or other liquids.

  • If the instrument has dropped into water, unplug the plug-in power unit immediately.

  • Ensure your hands are dry before handling either the instrument or the plug-in power unit.

  • Do not pull on the power cord or instrument to unplug the plug-in power unit from the socket outlet.

  • The plug-in power unit must be operated only from a power supply as specified on it.

  • If the power supply is damaged, don‘t use the adaptor anymore!

  • For reasons of hygiene, the device should only be used on one person.

Device description

  1. Manicure/pedicure device
  2. +/- speed regulation
  3. Battery level indicator
  4. On/off switch
  5. Clockwise/anti-clockwise rotation
  6. LED light
  7. Storage bag

Commencing operation

This manicure and pedicure device comes with high-quality attachments. The supplied 10 attachments are made with durable sapphire coating / polishing felt. Together with the continuously adjustable speed regulation and right/left rotation, professional foot and nail care at the standard of a pedicurist is possible. All the attachments can be easily integrated into the storage pouch of the MP 62. The integrated LED light additionally creates ideal light conditions during application.

After use, before cleaning and changing any accessory parts, the power unit should always be disconnected. Ensure that the sliding switch on the device is in the centre position (= off) before you connect the device to a power supply.

Application

  • This instrument is intended only for the treatment of hands (manicure) and feet (pedicure).
  • Make sure that the device is switched off beforehand.
  • Select an attachment and push it onto the instrument spindle using a slight pressure. The attachments can be heard to engage. To remove: pull the attachment and instrument apart in the axial direction (straight).
  • Turn the control ring to the left (anti-clockwise rotation) or to the right (clockwise rotation) to switch the device on. The LED lights up blue. The two buttons marked with plus (+) and minus (-) allow you to select the speed of rotation.
  • Start every application at low speed and increase it only as required.
  • All file and cutting attachments are coated with a sapphire grain. This guarantees extremely long life and almost guarantees freedom from wear.
  • Do not exert heavy pressure and always guide the attachments carefully over the surface to be treated.
  • Move the instrument under light pressure in circular movements slowly over the parts to be treated.
  • Note that the cutting attachments will have a reduced effect if the skin is softened or moist. For this reason, do not carry out any pretreatment in a bath.
  • Do not remove all the callus skin in order to retain the natural protection of the skin.
  • Always ensure that the spindle can rotate freely. It must never be permanently jammed, otherwise the instrument will become too hot and suffer damage.
  • After every use, apply moisturizing cream to the parts treated.

Important:
Check the results during treatment. This is particularly important for diabetics, since their hands and feet are less sensitive.

Attachments

Since the attachments are of a high quality and improper use can lead to injury, we ask that you handle the attachments carefully. At high speeds in particular, we advise that you proceed with caution. The following attachments are included:

A -­ Sapphire Cone

Suitable for removing dry skin and softening calluses on the sole and heel. Take care not to remove hardened skin entirely to protect the healthy skin beneath. File until a thin layer remains then moisturise to soften.

B – Coarse Sapphire Cone

Suitable for removing hard skin and large calluses from the sole and heel. Take care not to remove hardened skin entirely to protect the healthy skin beneath. File until a thin layer remains then moisturise to soften.

C -­ Fine-Grain Sapphire Wheel

Suitable for filing nails to reduce length. Whilst the sapphire disk rotates, the external housing remains fixed to prevent friction burns to the skin around the nails.

D ­- Coarse-Grain Sapphire Wheel

Suitable for filing thicker nails to reduce length. Whilst the sapphire disk rotates, the external housing remains fixed to prevent friction burns to the skin around the nails.

E ­- Cylindrical Cutter

Suitable for smoothing rough and ridged toenail surfaces. Simply, place the cylindrical cutter horizontally on the nail surface and removed the rough layer with slow circular movements.

F ­- Flame-Shape Cutter

Suitable for removing ingrowing nails.

G -­ Round Sapphire Cutter

Suitable for removing corns. Take care to remove the corn slowly, layer by layer to prevent damage to the healthy skin beneath.

H ­- Nail Cutter

Suitable for exposing ingrown nails and removing dead nail parts. When using this attachment, use at a low speed.

I ­- Felt Cone

Suitable for smoothing and buffing nail tips after filing and for cleaning the surface of the nails. Position the manicure tool and move around the nail in a constant circular motion.

J -­ Sandpaper Attachment

Rotating wheel for attaching sandpaper.

K ­- Single-Use Sandpaper Attachments

Suitable for removing dry skin and calluses from the sole and heel, and for filing nails. 30 pieces included.

L ­- Protective Nail Dust Cap

Captures nail dust as you file to minimise inhalation and clean up time.

When filing, always work from the outside of the nail towards the tip!
Always check results regularly during treatment. As soon as the application becomes unpleasant, stop the treatment.

Cleaning and maintenance

Before cleaning the power unit, always unplug it from the socket outlet! ­

  • Clean the instrument with a slightly moistened cloth. You can also moisten the cloth with mild soap suds to remove more stubborn dirt.
  • If necessary, for reasons of hygiene, the attachments can be cleaned with a cloth or brush moistened with alcohol. Dry them carefully afterwards.
  • Do not drop the instrument.
  • Make sure that no water enters the instrument. But if this should happen, do not use the instrument again until it is completely dry.
  • Do not use chemical detergent or scouring agents for cleaning.
  • Never immerse the instrument or plug-in power unit in water or other liquids.

Accessories and replacement parts

Replacement parts and wearing parts are available from the corresponding service address (according to the service address list). Please state the corresponding order number.

Description Article or order number
  • 1 x Sapphire Cone
  • 1 x Coarse Sapphire Cone
  • 1 x Fine-Grain Sapphire Wheel
  • 1 x Coarse-Grain Sapphire Wheel
  • 1 x Cylindrical Cutter
  • 1 x Flame-Shape cutter
  • 1 x Round Sapphire Cutter
  • 1 x Nail Cutter
  • 1 x Felt Cone
  • 30 x Single-Use Sandpaper Attachments
  • 1 x Protective Nail Dust Cap

| 572.14
Sandpaper Attachment| 163.526

Disposal

Please dispose of the device in accordance with EC Directive ­- WEEE (Waste Electrical and Electronic Equipment).
If you have any queries, please contact the appropriate local authorities.

Technical specifications

Supply
Input:
Output:| 100-240 V~; 50/60 Hz 0.5 A
30.0 V 0.25 A; 7.5 W
---|---
Average active efficiency:| ≥ 80.3 %
No-load power consumption:| ≤ 0.09 W
Speed:| 2,000 – 5,400 rpm +/- 20%
Device dimensions:| 158 x 35 x 36.5 mm
Weight:| Mains part: approx. 93 g
Device: approx. 111 g

Subject to technical changes

Warranty/service

Beurer GmbH, Söflinger Straße 218, 89077 Ulm, Germany (hereinafter referred to as “Beurer”) provides a warranty for this product, subject to the requirements below and to the extent described as follows.

The warranty conditions below shall not affect the seller’s statutory warranty obligations which ensue from the sales agreement with the buyer. The warranty shall apply without prejudice to any mandatory statutory provisions on liability.

Beurer guarantees the perfect functionality and completeness of this product.

The worldwide warranty period is 3 years, commencing from the purchase of the new, unused product from the seller.

The warranty only applies to products purchased by the buyer as a consumer and used exclusively for personal purposes in the context of domestic use. German law shall apply.

During the warranty period, should this product prove to be incomplete or defective in functionality in accordance with the following provisions, Beurer shall carry out a repair or a replacement delivery free of charge, in accordance with these warranty conditions.

If the buyer wishes to make a warranty claim, they should approach their local retailer in the first instance: see the attached “International Service” list of service addresses.

The buyer will then receive further information about the processing of the warranty claim, e.g. where they can send the product and what documentation is required.

A warranty claim shall only be considered if the buyer can provide Beurer, or an authorised Beurer partner, with

  • a copy of the invoice/purchase receipt, and
  • the original product.

The following are explicitly excluded from this warranty:

  • deterioration due to normal use or consumption of the product;
  • accessories supplied with this product which are worn out or used up through proper use (e.g. batteries, rechargeable batteries, cuffs, seals, electrodes, light sources, attachments and nebuliser accessories);
  • products that are used, cleaned, stored or maintained improperly and/or contrary to the provisions of the instructions for use, as well as products that have been opened, repaired or modified by the buyer or by a service centre not authorised by Beurer;
  • damage that arises during transport between manufacturer and customer, or between service centre and customer;
  • products purchased as seconds or as used goods; – consequential damage arising from a fault in this product (however, in this case, claims may exist arising from product liability or other compulsory statutory liability provisions).

Repairs or an exchange in full do not extend the warranty period under any circumstances.

Beurer GmbH · Söflinger Str. 218 · 89077 Ulm, Germany www.beurer.com · www.beurer- gesundheitsratgeber.com www .beurer-healthguide.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals