ALL SECURITY EQUIPMENT FAS-SLIDECH300BBUP Sliding Gate Operator User Manual
- June 5, 2024
- ALL Security Equipment
Table of Contents
Sliding Gate Operator
User’s Manual
FAS-SLIDECH300BBUP
Products introduction
please read the instructions carefully before proceeding.
The operator contains Extra battery, transformer, control board and radio
control.
In case of power of failure, the operator is powered by a 24Vdc, 1.3Ah,
extra battery.
Intelligent charging system supplied.
MCU is supplied to control the gate operator.
Keypad / single button interface.
Photo beam safety beam interface.
Users can select the Auto-close feature
Soft start & soft stop.
Manual key release design for emergency purposes.
The Gate operator has an auto-reverse function, and the reverse power can
change by the user.
Important safety information
Carefully read and follow all safety precautions and warnings before
attempting to install and use this automatic gate operator.
Make sure the Power supply(AC110V) of the operator is suitable for the
power supply in your area.
Main technical parameters
Unit Model | **** FAS-SLIDECH300BBUP |
---|---|
Power Supply | 110VAC |
Maximum gate weight | 300Kg |
Maximum gate width | 8m |
Motor | 24VDC 100W |
Output torque | Max. 8N·m |
Work duty | S2 30min |
Limit switch | Electronic Limit |
Gate Move speed | 12m/min |
Remote control range | ≥30 meters |
extra remote control | 20 |
Frequency | 433.92 MHz |
Noise | ≤60 dB |
Working temperature | -20ºC ~ +50ºC |
Extra Battery | 24V 1.3 Ah |
Mechanical Installation
The FAS-SLIDECH300BBUP will handle gates weighing up to 300kg and up to 8m if
the proper installation procedures have been followed.
The FAS-SLIDECH300BBUP gate operator operates by forcing a drive chain by a
drive chain wheel.
The entire configuration is shown in the diagram below. The gate operator must
be installed on the inside of the gate.
Installation and Adjustment
The FAS-SLIDECH300BBUP Chain-driven Gate Operator operates by forcing a
straight piece of chain through its chain box. This length of chain is
extended between two chain brackets located at opposite ends of the gate. The
entire configuration is shown in the pack list.
Concrete Pad
The base unit of the gate operator requires a concrete pad in order to
maintain proper stability. The concrete pad should be approximately 24”
(600mm) x 12” (300mm) x 18” (460mm) deep in order to provide for adequate
operation.
Once the gate is mounted adequately, electrical power is available, and the
concrete pad is poured, you are ready to proceed.
Anchors
You can use the anchors that are provided with the operator, 3 ¾ anchor bolts
(4), anchors, washers, and nuts. These anchors must be set into the concrete
when it is poured, or you can use wedge anchors (1/4” x 4”).
Operator Base
Mount the gate operator base to the concrete pad. The distance between the
gate and the base should be no more than 2 ½ “ (64mm). Verify that the
operator is leveled properly.
Chain Box
Make sure the ends of the guide chain are out of the chain holes on both sides
of the chain box.
Remove the cover and insert the manual release key and turn counter-clockwise
to disengage the clutch.
Remove the elastic band from the shaft and line up the key on the shaft with
the sprocket at the chain box.
Insert the sprocket from the chain box into the operator shaft. Place the
operator on top of the base and use (4) 5/8 “ (M8x15mm) socket head cap screws
to mount the chain box into the base.
Operator
Mount the gate operator to the base using (4) 2 ¾ “ (M8x70mm) #48 bolts and
washers. Make sure there is no more than 1/8” (2mm) of space between the cover
and the chain box. Check the operator and make sure it is lined up with the
gate.
Chain Brackets
Use the appropriate bolts to attach the chain bracket to the frame of the
gate. If the gate is of square frame style, use the square bolts shown.
If the gate is of round frame style, use the round bolts shown.
Chain
Close the gate and attach a chain bolt to the piece of chain that comes with
the chain box using enclosure master links. Tighten the chain bolt to the
bracket with washers and nuts. Pull the chain through the chain wheel box to
the other chain bracket at the opposite end of the gate. Connect the other end
of the chain and the chain bolt, and then tighten the chain bolt to the chain
bracket. Thread up the chain by adjusting the chain bolt. Cut the chain to
length if necessary. Make sure that the chain is perfectly aligned with the
chain holes on the chain box. Tighten the chain by tightening the chain bolts
at either end. See the illustration below.
Gate preparation
Be sure the gate is properly installed and slides smoothly before installing
the FAS-SLIDECH300BBUP sliding gate operator. The gate must be plumb, level,
and move freely.
Conduit
In order to protect the wires, use PVC conduit for low voltage power cable and
control wires. Conduit must be preset into the concrete when it is poured.
Wires within the conduit shall be located or protected so that no damage can
result from contact with any rough or sharp part.
Concrete pad
The base unit of the gate operator requires a concrete pad in order to
maintain proper stability. The concrete pad should be approximately 400mm x
250mm x 200mm deep in order to provide adequate weight and structure to insure
proper stable installation.
Anchors (see Fig.2)
You can use anchor bolts, anchors, washers, and nuts. These anchors must be
set into the concrete when it is poured or you can use wedge anchors to fasten
the operator.
Adjustment
Manual operation
In case of power failure use the manual release key to open or close the gate
manually, use the release key as follow:
- Fit the supplied key in the hole.
- Turn the key clockwise to release the clutch.
- Open and close the gate manually.
- After power-restored use the manual release key to tight the clutch by turning the key counterclockwise and resume normal operation.
NOTE: The gate operator needed to reset the limit after re-tight the clutch by turning the key counterclockwise if the power fails and is released by hand.
Wire Connecting
Connecting the battery
Plug the terminal of the Extra battery into the control board.
NOTE: If you do not use the gate operator and power failure, please pull
out the extra battery terminal.
Connecting the motor
Connect motor wires to ‘M-’ and ‘M+’ of terminal blocks T1 (BLACK)and T2(RED).
Connecting power wire
Electrical and control board
Motor: black wire to T1 and red wire to T2.
J1: transformer secondary(AC24V/3.3A) external Push Button(J2,J3,J4): Single
Button(OSC and COM)
Three-Button(K,G,T,and COM),
Photo beam(PE and COM)
Output DC power: 24 and GND
J5: solar panel(10W 27V) and charge Battery.
NOTE: Please put through the “J5”(Battery) terminal if you need to use the
sliding operator.
Programming Process
SET button: Mode set and Confirm function
CODE button: Transmitter set and clear function
OPEN button: open door
CLOSE button: close door
Adding extra transmitter (learn)
- Press CODE and a dot are indicated on the LED display.
- Press the transmitter button which you want to use (buttons 1, 2, 3, 4), then press the same button again.
- The dot on the LED display will flash and then turn off.
- ||’ is indicated on the LED display, then the learning process is finished.
Up to 20 transmitters may be used.
Erase transmitter
Press and hold CODE until ’C’ flashes on the LED display. This indicates that
all the transmitters have been erased completely.
Set open and close positions
- Press and hold SET until number ’1’ is indicated on the LED display.
- Press and hold OPEN to set the open position(now the door must be OPEN, if not, please change the motor wire to red and black), and release the button until the door has reached the desired position. (You also can press CLOSE to move the door close, OPEN and CLOSE can be used to fine adjust the door position.)
- Press the SET to confirm the open position, now number ’2’ is indicated on the LED display.
- Press and hold CLOSE to set the close position, and release the button until the door has reached the desired position. (You also can press OPEN to move the door open, OPEN and CLOSE can be used to fine adjust the door position.)
- Press the SET to confirm the close position.
- The door will do a complete open and close cycle.
Automatic close (0~90 seconds adjustable)
- Press and hold OPEN until ’─’ is indicated on the LED display.
- Press OPEN to increase the auto-close time, press CLOSE to decrease time.
- Set the timer to ’0’, and the automatic close function will be disabled.
- Press SET to confirm the setting.
- Add 10 seconds per number
NOTE: Automatic close function is available only when the door is in the fully opened position.
Setting obstruction force
If the door meets an obstruction during the closing, it will stop and reverse
about 15cm~20cm.
- Press and hold SET. The LED will display numbers from ’1’ to ’4’, when the number ’3’ appears on the LED display, release the SET.
- Press OPEN to increase the obstruction force, the maximum force is level 9. Press CLOSE to decrease force, the minimum force is level 1.
- Press SET to confirm.
Photo beam:
Connect the photo beam following Figure. The photo beam output signal must
be an N.C. signal.
Press and hold close until ’─’ is indicated on the LED display. release the
close,’11’ will be indicated on the LED display. Press open, and will
indicate on the LED display. Press SET to confirm. Then Connect the photo
beam to follow the Figure. ( Note: When not using photo beam, please
click the above action and set it to “11” status)
Maintenance
- Check the door once a month. The door should be carefully checked for balance. The door must be in good working order.
- The auto-reverse function should be regularly inspected and adjusted if necessary. For service, call an experienced serviceman.
- We suggest for safety reasons, photocells are used on all gates.
- Disconnect from the mains supply before replacing the bulb.
- Be sure to read the entire manual before attempting to perform any installation or service to the door operator.
- Our company reserves the right to change the design and specification without prior notification
Troubleshooting
Trouble | Possible causes | Solutions |
---|---|---|
The door fails to open and close. LED display does not light. | 1. Power is |
OFF
2. Fuse burn| 1. Make sure that power is ON.
2. Replace fuse.
The door can open but fails to close.| 1. Infrared beam is obstructed. 2.
Infrared photocell function is enabled, but the photocell has not been
installed.| 1. Remove obstructions.
2. Make sure the infrared photocell function is disabled.
The remote control does not work.| 1. Battery level may be low,
2. Transmitter| 1. Replace the battery inside the transmitter.
2. Re-program the transmitter.
The transmitter operating distance is too short.| The battery level may be
low.| Replace battery.
Packing list
After receiving the gate operator, you should make an unpack inspection, in
which you should check whether the product was damaged. If you have any
problem please contact our dealer. You should find the following items in our
standard packing:
Pack list
No. | Item | Quantity |
---|---|---|
1 | FAS-SLIDECH300BBUP sliding gate operator | 1 |
2 | Operator Base | 1 |
3 | FAS-J-4CH TX transmitter | 2 |
4 | Master Links | 2 |
5 | Chain | 1 |
6 | Chain Bolts | 2 |
7 | Chain Brackets | 2 |
8 | “U” Bolts for square & round gate frame | 4 |
9 | 2 ¾_ (M8x 70mm) Bolts for mounting operator to the base and washers | 4 |
10 | 2 ½_ (M8x65mm) Bolts for mounting Magnet brackets and washers | 4 |
11 | 3 ¾_Anchor bolts, Anchors, Washers, and Nuts (In the same bag | 4 |
with manual release key) | ||
--- | --- | --- |
12 | 5/8_ (M8x15mm) Socket Head Cap screws for mounting chain box | 4 |
13 | Manual release key | 1 |
14 | User’s manual | 1 |
www.allsecurityequipment.com
Email: hello@fastaccesssecurity.com
6929 NW 52nd STREET MIAMI , FLORIDA 33166 / Tel: +1 ( 305) 437-9757
References