ALL Security Equipment Surface Mount Single 1200LSDM Magnetic Lock User Manual

June 4, 2024
ALL Security Equipment

ALL Security Equipment Surface Mount Single 1200LSDM Magnetic Lock User Manual
ALL Security Equipment Surface Mount Single 1200LSDM Magnetic
Lock

Specification

Model

| Size(mm)| Voltag e| Current| Holding Force| LockSignal| DoorSignal| Time|

Door

---|---|---|---|---|---|---|---|---
Single door magnetic lock| 260Lx54.7Wx29.6H| DC12V(Default); DC24V(Order)| 12V/500mA±10%

24V/250mA±10%

| 350kg(800Lbs)| NO| NO| No| Single Door
Single door magnetic lock with signal| 260Lx54.7Wx29.6H| DC12V(Default); DC24V(Order)| 12V/500mA±10% 24V/250mA±10%| 350kg(800Lbs)| NO/NC/COM| NO| No| Single Door
Single door magnetic lock with time delay| 260Lx54.7Wx29.6H| DC12V(Default); DC24V(Order)| 12V/500mA±10% 24V/250mA±10%| 350kg(800Lbs)| NO/NC/COM| NO| 0/3/6/9sec.| Single Door
Single door magnetic lock with bond sensor Double door magnetic lock| 260Lx54.7Wx29.6H| DC12V(Default); DC24V(Order)| 12V/500mA±10% 24V/250mA±10%| 350kg(800Lbs)| NO/NC/COM| NO/NC/COM| No| Single Door
520Lx54.7Wx29.6H| DC12V(Default); DC24V(Order)| 12V/S00mA±10%x2 24V/250mA±10%x2| 350kgx2(800Lbsx2)| NO| NO| No| Double Door
Double door magnetic lock with signal| 520Lx54.7Wx29.6H| DC12V(Default); DC24V(Order)| 12V/S00mA±10%x2 24V/250mA±10%x2| 350kgx2(800Lbsx2)| NO/NC/COM| NO| No| Double Door
Double door magnetic lock with time delay| 520Lx54.7Wx29.6H| DC12V(Default); DC24V(Order)| 12V/S00mA±10%x2 24V/250mA±10%x2| 350kgx2(800Lbsx2)| NO/NC/COM| NO| 0/3/6/9sec.| Double Door
Double door magnetic lock with bond sensor| 520Lx54.7Wx29.6H| DC12V(Default); DC24V(Order)| 12V/S00mA±10%x2 24V/250mA±10%x2| 350kgx2(800Lbsx2)| NO/NC/COM| NO/NC/COM| No| Double Door

Diagram (unit:mm)

  • Single door magnetic lock
    Product Dimension
    Product Dimension

  • Single Door Magnetic Lock with Signal & Time delay
    Product Dimension

  • Single Door Magnetic Lock with LED & Bond Sensor
    Product Dimension

  • Double door magnetic lock
    Product Dimension

  • Double Door Magnetic Lock with Signal & Time delay
    Product Dimension

  • Double Door Magnetic Lock with LED & Bond Sensor
    Product Dimension

Installation

  • Fold the plate to 90°.

  • Close the door first, then place the upper side of template on door frame, while adjust the left side next to the door leaf.

  • Mark screw positions of armature plate and magnetic lock on door leaf and door frame respectively.

  • Drill holes based on the marked positions.

  • Make a combination based on the picture.

  • Strike the pin into the armature plate slightly (to avoid movement).

  • Make a combination based on the picture(add washer accordingly). The rubber ring must be added.

  • Place the rubber ring between armature plate and door leaf.

  • Use Allen key to remove the mounting plate from lock body.

  • Fix the mounting plate on the door frame according to the holes drilled earlier.

  • Use Allen key to screw the lock body on the mounting plate.

  • Close the door to test holding force. The angle between armature plate and magnetic lock can be adjusted by adding or reducing washers.

  • After all the appropriate procedures, the holding force can be maximized. Finally, fix the tamper screw.

  • Drill a hole
    Inside: Diameter is 8mm
    Outside: Diameter is16mm

  • Drill a hole
    Inside: Diameter is 8mm
    Outside: Diameter is 12.7mm

  • Inside: Drill a hole diameter is 8mm folding the plastic straight pin.

Notice:

Thickness of Door Leaf:
350LBS: 44mm 600LBS: 50mm 800LBS: 48mm 1200LBS: 46mm

  • A. The screw of armature plate should not be fixed too tight. Proper elasticity should be guaranteed for the rubber ring so that the armature plate can adjust itself to the appropriate position.
  • B. Check the jumper’s position before connecting. Figure out it represents 12VDC or 24VDC.

Bracket Installation

Different brackets are available according to different types of doors. For example, narrow door, frameless glass door and inward opening door.

L Bracket
When the door frame thickness is less than 42mm, L bracket is needed.
Bracket Installation
Bracket Installation

LC Bracket
LC Bracket one-piece design,wires are mortised.no damage ori wires.
Bracket Installation
Bracket Installation

ZL Bracket
If install a bracket on inward opening door,ZL bracket is needed.
Bracket Installation
Bracket Installation

GZ Bracket
One-piece design, durable&professional design, easy installation, suitable for 10-1 5mm frameless glass door.
Attention: No GZ bracket for S00kgs series available currently.
Bracket Installation
Bracket Installation

U Bracket
If door leaf is glass.need U bracket to be used with lock (suitable for 10-12mm glass door)
Bracket Installation

Installation of Armature Plate
If door leaf is too thick.need to choose I bracket
Bracket Installation

Circuit Board Diagram

A.12VDC Input:
Connect the positive(+)lead from a 12VDC power source to V +.
Connect the ground(-)lead from a 12VDC power source to V -.
Check jumper for 12 VDC operation.

B.24VDC Input:
Connect the positive(+}lead from a 24VDC power source to V +.
Connect the ground(-)lead from a 24VDC power source to V -.
Check jumper for 24 VDC operation

Wiring Instruction of Single Door Magnetic Lock

Wiring Instruction

Model with DS will come with one more set of signal for door sensor and lock status(NO/NC/COM contact)

Model with Twill come with this function.

Wiring Instruction of Double Door Magnetic Lock

Connection: green wire or white plug, except the models without LED indicator and signal output; only when it detects that double doors have been locked, there will be normal signal output.
Wiring Instruction

Wire Connection

Wire Connection

Support

www.AllSecurityEquipment.com
Phone: +1 (305)427 9757
Email: hello@allsecurityequipment.com
Address: 6929 NW S2nd St. Miami,FL 33166 USA

Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals