TRIFIELD TF2 EMF Meter User Guide
- June 5, 2024
- TriField
Table of Contents
TRIFIELD TF2 EMF Meter
How to properly install the 9 volt battery
Press and Slide the rear battery door downward. Note the battery polarity. If the battery is installed backwards, this will not harm the meter, but the meter will not work until the battery is correct.
Insert the bottom of the battery into the center of the compartment at an angle.
Replace the battery when the battery level icon in the upper right corner of the LCD drops to zero bars. Typical battery life is 20 hours.
Audio and Light
Audio and light buttons are located in the battery compartment.While the meter
is on, you can press these green buttons to turn the backlight on or off
and to turn the audio option on or off.
Reading the LCD Display
Measuring Fields is simple☺
For Magnetic (MAG) Fields (power lines, appliances, wiring in walls, and motors) turn the knob to Standard MAG or Weighted MAG. A typical home with low EMF will read less than 3.0 milli-gauss on Standard MAG and less than 5.0 milligauss on Weighted MAG. Covering the top of the meter will not affect the magnetic reading.
For both Electric (ELEC) and Radio (RF) field measurement, hold the bottom half of the meter below this point. Do not block the top of the meter with your hand. Point themeter outward, away from your body. The reading may be higher when holding the meter than if it is set down. This is because the body concentrates the field. Therefore, hold the meter to obtain a true reading of your full exposure.
For Electric (ELEC) Fields (fluorescent lights, wall outlets and wiring, and electrical switches), turn the knob to Standard ELEC or Weighted ELEC. In an electromagnetically quiet home or office, both Standard and Weighted ELEC will read less than 50 V/m.
For Radio/Microwave (RF) frequencies (cell phones, WiFi routers, microwave ovens, and radio/tv stations), turn the knob to RF. Note that the brief pulses sent by transmitting cell phones and WiFi routers will be displayed in the peak measurement in the upper left corner of the LCD. A Radio quiet area will typically have less than 1.000 milli-watts per square meter as a peak. The field measurement numbers should read less than 0.200 milliwatts per square meter.
Frequently Asked Questions
Do I measure on Standard or Weighted or both?
Both. Standard MAG or ELEC measures the strength of the field regardless of
frequency (40Hz-100kHz). Weighted MAG or ELEC emphasizes the higher
frequenciesabove 60Hz. Higher frequencies will create more electric current
inside the human body. For example, at 60Hz, the body is receiving field
pulses 60 times per second, while at 120Hz, the body is receiving twice the
number of pulses, or 120 times per second, though the field remains the same.
What is a ‘safe’ level?
Absolute safe levels have not been established. However, according to our
research, there have not been problems associated with staying below:
- 3mG Standard Magnetic or 5mG Weighted Magnetic
- 50 V/m Standard or Weighted Electric
- 0.200 mW/m² RF (field measurement) or 1.000 mW/m² (peak measurement)
Exposure Levels mentioned here are typical readings taken from homes and offices that are relatively low in total electromagnetic fields. Legal maximum exposure levels are MUCH higher than the levels described above. Some practitioners may recommend somewhat different levels.
When do I use Magnetic (MAG), Electric (ELEC) or Radio (RF)?
Typical magnetic fields are emitted by motors, appliances, wiring, and power
lines. Electric fields are emitted by power lines, lights, wall outlets,
electrical switches, and ungrounded appliances. RF is found near transmitting
cell phones and wifi routers, cell phone towers, microwave ovens, smart
meters, wireless landline phones or walkie-talkies, and radio/tv stations.
Power company smart meters only pulse about once per minute. Watch for the
peak number. In order to reduce exposure, avoid high-field areas or use
shielding. Each type of field has simple, specific shielding techniques (see
online guide).
What is the difference between the large numerals (field measurement) and
the small numerals (peak measurement)?
The large numerals display the field measurement in real time and correspond
to the field percentage indicator graph. The peak measurement captures the
highest number and holds that number for 5 seconds or until a larger number is
read. For reading magnetic and electric fields, the field measurement numbers
work very well. For cell phones, cell towers and wifi routers that emit in
pulses, the peak measurement numbers are more useful.
Will this meter measure 5G?
Yes. This meter will measure current standard 4G (4th Generation) AND 5G
(Fifth Generation) radio frequency bandwidths from 600 MHz to 6GHz. Proposed
(future) bandwidths from 24GHZ to 86GHz cannot be measured currently.
What is the AlphaLab, Inc. warranty on the Trifield TF2 meter?
We offer a one-year limited warranty from the date of purchase under normal
use and service on all AlphaLab meters. If you have questions about the
function of your meter, please visit www.trifield.com/support or email us at
support@trifield.com
If the display reads MAG 1–.-, or ELEC 1—- or RF 1-.—, what does this
mean?
This indicates that measurement for that type of field is over-range, meaning
fields above 100.0 on magnetic or 1,000 on electric or 10.000 on RF. This does
not harm the meter.
For Full Product Literature and Shielding Information, visit trifield.com
More Questions?
Our five-minute video answers most questions. Go to trifield.com and click
Video in the upper right. or Call Toll-Free (USA)
1-800-658-7030 (Or Call
1-801-487-9492)
WEEKDAYS 9am-5pm MST
The T ®rifield Model TF2 meter is manufactured in USA by
AlphaLab,Inc., Salt Lake City, UT
For more information, visit www.trifield.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>