Technical Specifications

Product specifications

Model ASPA-400
Rated voltage/frequency 120V~ /60Hz
Rated power 60W
Rated current 0.85A
CADR (particulate matter) 233CFM
Noise 55dB
Net weight 6.3kg
Gross weight 8.4kg

Product size

| 382x200x645mm
Package size|

475x285x760mm

Work environment| Temperature:14°F-104°F(-10℃-40℃) humidity:≤95%RH

Real-time display of air quality conditions

PM2.5 value Air quality PM2.5 air quality indicator Wind speed gear
0-12 Excellent Green Sleep gear
13-35 Good Blue
36-55 Medium Yellow
>55 Poor Red

Safety Precautions

The following safety precautions and instructions must be read carefully and observed when the product is used!


Prohibitory sign

| The behaviors with this sign must be prohibited, otherwise it may cause product damage or endanger the user’s personal safety.
---|---


Warning sign

| The behaviors with this sign must be operated in strict accordance with the requirements, otherwise it may cause product damage or endanger the user’s personal safety.


Attention sign

| The behaviors with this sign must be paid attention to, otherwise it may cause product damage or other losses due to improper operation.

| Please do not touch the power plug with wet hands.|

| Please regularly clean the machine and power plug.
---|---|---|---

Please do not block the air inlet/outlet.

| Only the 120V power sockets are 120V power sockets.
Please do not use the machine in any place with much oil fume or high humidity.| Please do not put it close to or on any heat source (such as a fireplace, stove or a place

with flammable gases).

 | Please do not rinse the high-efficiency composite filter with water.| Please be careful when cleaning the air purifier, as corrosive detergents may damage the surface.
This machine shall not be used by people with disabilities, perceptual disturbance or dysgnosia or children alone, unless they use it under the supervision and guidance of safety director on the site.| Please do not unplug the power cord from the power socket when cleaning the air purifier or leaving it unused. Otherwise, it may cause electric shock due to poor insulation or fire due to short circuit.

Product Components

Structure and name of product components

  1. Filter cover
  2. Composite filter
  3. Host
  4. Touch control button and air quality indicator light

Operating Instructions

ASPEN-ASPA-400-Air-Purifier-2

The switching sequence of corresponding gears

ASPEN-ASPA-400-Air-Purifier-3

Product Features

Integration of multiple functions

  • Efficiently purify PM2.5, smoke, pollen and other particulate pollutants
  • 3 gears of wind speed
  • Timing (operated on the APP)
  • Prompt for replacement the filter (operated on the APP)
  • Configured with three operating modes, namely, manual, intelligent and sleep
  • Wi-Fi connection
  • Monitoring of PM2.5 concentration; display of air quality through different colors of the LED light (the concentration value can be checked on the APP in real time)

Threefold purification technology

ASPEN-ASPA-400-Air-Purifier-5

Instructions for use

Precautions for use

  • All filters are attached in the air purifier.
  • Please ensure that the plastic protecting bag outside the filter is removed and installed correctly before use.

ASPEN-ASPA-400-Air-Purifier-6

  1. Open the filter cover according to the marking keys on the product
  2. Take out the filter cover when it pops up. ASPEN-ASPA-400-Air-Purifier-7
  3. Take out the filter inside the machine
  4. Remove the plastic protecting bag on the filter.ASPEN-ASPA-400-Air-Purifier-8
  5. Put the filter without bag back into the machine
  6. Put the filter cover back

Start to use

ASPEN-ASPA-400-Air-Purifier-9

  1. Insert the power plug into the 120V power socket; the machine is powered on, and the buzzer makes a “ding” sound.
  2. Power on by touching the power key.

Cleaning and Maintenance

Please unplug the power plug from the power socket before machine maintenance

  1. Clean the machine body:

  2. Wipe off stains with a soft rag.

  3. Wipe off stubborn stains with a soft rag dipped with proper amount of neutral detergent.
    Note: Please avoid scratching the machine shell with any hard object during maintenance. Please operate according to the manual and avoid damaging any machine part during base disassembly.

  4. Clean and replace the filter:

  5. The replacement of filter will be reminded by the built-in program. The filter mesh can also be replaced according to the service life prompt of filter. It can also be replaced in real time through the filter life reset function.

  6. The vacuum cleaner can be used to clean the deposited dust on the surface of the composite filter to prolong the service life of filter mesh (it is recommended to clean it once every other month and do not wash with water). The service life of filter may vary with different environments for using the machine. For example, it will be shortened in smoking areas and areas with pets. Please replace the filter in time when the purification effect becomes worse. Please dispose the used waste filter according to the relevant regulations on solid waste.

FAQ & Solutions

ASPEN-ASPA-400-Air-Purifier-10

Warranty

Warranty Card

Customer Name|  | Phone number|
---|---|---|---
Place of Purchase|  | Date of Purchase|
Product Name|  | Product Model|
Batch No|
Maintenance Date| Maintenance Records| Remarks
 |  |  |
 |  |  |
 |  |  |
 |  |  |

Thank you for purchasing and using this product. You can enjoy the following after-sales warranty services with this card as long as you have purchased this product in any authorized shop or online store.

  1. You can unconditionally return/exchange the product in case of any quality problem within 7 days of purchase.
  2. You can request for maintenance for free (the filter mesh is covered by warranty) in case of any quality problem within 1 year from the date of purchase.

Statement: The after-sales warranty will not be provided for the following circumstances

  1. The product is purchased in any unauthorized shop or online store.
  2. The product is purchased in any authorized shop or online store, but without a warranty card.
  3. There is any damage caused by force majeure, such as natural disasters.
  4. There is any artificial damage or arbitrary disassembly due to improper use, repair and maintenance beyond the manual.
  5. The warranty card is filled in incompletely or altered and the contents on the card are inconsistent with the

FCC Caution

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:?(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna. FCC ID: 2A6AP-ASPA-400

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ASPEN User Manuals

Related Manuals