Brief Introduction

This machine which uses sugar as the main material, with some other ingredients, can make various flavors and colorful candy floss. The product will not be the simple white candy floss but one of different colors, like red, yellow, green, strawberry, peach, watermelon, litchi, or mango. It will be not only healthy but also delicious.

Main Parameter

Model ZWET52
Dimension 520X520X910
Heating power 1000 w
Motor power 80W
Electric voltage 230V
Frequency 50Hz
Yield 1 / 30sec

Structure of Machine

Preparation

  1. Please read the instruction book carefully before using it, know the machine structure, performance, main spare parts, and safe operation as well, then we can make good use of this machine, get a better working affection.
  2. After taking the machine out of the packing carton, fit the spare parts to the right place.
  3. The user should clean the heating head and the stainless steel pan firstly, the water will be thrown out when the head runs, then swept it with a soft cloth.
  4. This machine should be put on a strong worktable, and also should have a suitable distance from the ground.
  5. Before turning on the machine, the user should check whether the electric voltage is the same as the machine voltage, whether the electrical outlet meets the safety standard, and whether you have installed the switch of creepage protection.

Operating instructions

  1. When moving the machine, press down little the handle to make sure the cart’s front legs leave the ground.
  2. Turn on the power switch to let the machine run for 1-2 minutes, Please check whether the machine runs steadily or not. ( It needs to adjust if the machine shakes strongly, the user must make sure the machine is put steady and the head runs right).
  3. Turn on the booster to biggest, then let the machine warm up for about 4-5 minutes. (the power is higher, and the heating speed is quicker.)
  4. Put one spoon of clean granulated sugar into the center of the running head.
  5. The candy floss will get out after 30 seconds, then use a bamboo stick or other related object to stick the candy floss, revolve follow the inside of the pan. (the bamboo stick needs clean with a wet cloth)
  6. After finishing the candy floss, Please don’t stop the machine at once, clean the turning dish with water (keep the head running then put little water into the inlet), turn off the switch, then sweep the head with a soft cloth. If you want more candy floss, just repeating the above steps is fine.

Notes

  1. Minorities are forbidden to use this machine.

  2. Have to use an electrical outlet with a ground line. Keep the cable away from the heat; Don’t immerse the cable, electrical plug, and machine into water or other liquids; Don’t use the broken cable, electrical outlet, and plug.

  3. Installing the heating head and pan correctly, then put them into the plug. Turn off the power switch when stops working, move the pan and clean it with water.

  4. Don’t touch the surface of the heat and heating head when working and don’t put the hand into the pan if still sugar inside, in case of being burnt, and also don’t move the machine when working.

  5. Do not touch with plug, or electric cable when they are moistened by water, in case of being shocked by electricity.

  6. The temporary piece rate of the electric motor is 80%, Please avoid a long time of continuous working as to prolong the service life of the electric motor, it should pause for 20 minutes after working continuously for an hour.

  7. No matter whether cleaning the machine, or maintaining it, it should close the power supply, and pull out the electrical plug firstly; Disallow this machine empty from running for long hours.

  8. don’t use detergent when sweeping, in case of the detergent left on the machine result in pollution. It also can’t be washed with water directly, for this may moisten the
    electric spare parts and damage the machine.

  9. If the heating head does not run, Please turn off the power switch, and clean the burnt sugar inside with a soft cloth.

Electrical Date

  • L———- Copper sheathed cable
  • T———- Temperature limiter
  • M———- 80W Ac motor
  • V———- 0~300V Ac voltage meter
  • Fuse——— Tubular fuse
  • R———- 1000W heating plate
  • K———- Main switch
  • K1———- Heating switch

Spare Parts List

(The list is for ET-MF05 only)

No. Name Quantity Remark No. Name Quantity Remark
1 Wheel 2 pieces   11 Screw 8 pieces M4X12
2 Feet pipe 2 pieces   12 Nut 8 pieces M4
3 Wheel feet pipe 2 pieces   13 Screw 4 pieces M5X16
4 Beam 3 pieces   14 Support plate 2 pieces
5 Handle block 1 set   15 Screw 6 pieces M5X30
6 Handle pipe 1 piece   16 Sugar spoon 1 pieces
7 Ring 2 pieces   17 wheel axes 1 pieces
8 Wrench 1 piece   18 wheel screw 2 pieces M12X70
9 Screw 8 pieces M5X8 19 Wheel cover 2 pieces
10 Nut 8 pieces M4 20 belt 1 pieces