AL-KO SUB 6500 Classic 250W Electric Submersible Water Pump Instructions
- June 5, 2024
- AL-KO
Table of Contents
SUB 6500 | DRAIN 7000 – 7500 | DRAIN 7200
© 2016 AL-KO KOBER GROUP Kötz, Germany
This documentation or excerpts therefrom may not be reproduced or disclosed to
third parties without the express permission of the AL-KO KOBER GROUP.
| SUB 6500 (Art.Nr. 112 820)| DRAIN 7000 (Art.Nr. 112 821)
DRAIN 7500 (Art.Nr. 112 822)| DRAIN 7200 (Art.Nr. 113 507)
---|---|---|---
| 250 W| DRAIN 7000: 350 W
DRAIN 7500: 450 W| 430 W
| 230 V AC/50 Hz| 230 V AC/50 Hz| 230 V AC/50 Hz
| X 8| X 8| X 8
| 5 m| 5 m| 5 m
| 6 m| DRAIN 7000: 6 m
DRAIN 7500: 6 m| 6 m
| 6500 l/h| DRAIN 7000: 7000 l/h
DRAIN 7500: 7500 l/h| 7200 l/h
| 35 °C| 35 °C| 35 °C
| 8 cm| 13 cm| 13 cm
| 2 – 3 mm| 30 mm| 30 mm
| 4,0 kg| 4,4 kg| 4,4 kg
| 2,5 cm| 3 cm| 3 cm
| on: 38 cm
off: 17 cm| on: 41 cm
off: 20 cm| on: 41 cm
off: 20 cm
| 10 m| 10 m| 10 m
TRANSLATION OF THE ORIGINAL OPERATING INSTRUCTIONS
PRODUCT DESCRIPTION
This document describes various different models of immersion pumps. Identify your model using the identification plate.
Product overview
1 | Carrying handle |
---|---|
2 | Connection cable |
3 | Float switch cable |
4 | Pump housing |
5 | Combination adapter |
6 | Float switch |
7 | Connection elbow |
8 | Suction slots |
Function
The immersion pump draws the conveying me- dium through the suction slots
directly and feeds it to the pump outlet. It is switched on and off using a
float switch.
Designated use
The immersion pump is designed for private use in the house and garden. It
must only be operated within the framework of the deployment limitations in
accordance with the technical data.
ABOUT THIS HANDBOOK
- Read this documentation before starting up the machine. This is a precondition for safe working and flawless operation.
- Observe the safety warnings in this documentation and on the product.
- This documentation is a permanent integral part of the product described and must be passed on to the new owner if the product is sold.
Explanation of symbols
CAUTION!
Following these safety warnings carefully can prevent personal injury and/or
material damage.
ADVICE
Special instructions for greater ease of understanding and improved handling.
The immersion pump is suitable for:
-
Water removal in the event of a flood
-
Re-pumping and pumping out from vessels (e.g. swimming pools)
-
Water removal from streams and shafts
-
Water removal from drains and trickle shafts.
➯ only on the DRAIN pump
The immersion pump is only suitable for conveying the following fluids: -
Clearwater, rainwater
-
Chlorine-containing water (e.g. swimming pools)
-
Wastewater
-
Dirty water has a suspended matter proportion of max. 5 % and a grain size of max. 30 mm diameter.
➯ only on the DRAIN pump
Any use not in accordance with this designated use shall be regarded as misuse.
Possible misuse
The immersion pump must not be used continuously.
They are not suitable for conveying:
- Drinking water
- Saltwater
- Foodstuffs
- Aggressive media, chemicals Scope of delivery
- Corrosive, flammable, explosive or fuming fluids
- Fluids that are hotter than 35 °C
- Water containing sand and abrasive fluids
➯ only on SUB pump
SCOPE OF DELIVERY
Thermal protection The unit is fitted with a thermal protection switch that switches the motor off in the event of overheating. The pump switches on again automatically after a cooling down period of approx. 15 20 minutes. Operate the unit only if the immersion pump is fully immersed.
**SAFETY INSTRUCTIONS
**
CAUTION!
Risk of injury! Use the machine and the extension cable only in perfect
working order. Damaged equipment may not be operated. Do not disable safety
and protective devices!
- Children, or people who are not familiar with the operating instructions, are not allowed to use the machine.
- Never lift, transport or suspend the unit using the connection cable.
- Unilateral modifications or conversions of the unit are prohibited.
Electrical safety
CAUTION! Danger when touching voltage conducting parts! Disconnect the
plug from the mains if the extension cable is damaged or severed! We recommend
connecting a RCD (residual current operated device) having a nominal residual
current of < 30 mA.
- The pump may not be operated while people are in the pool or pond.
- The house mains voltage must agree with the details quoted in the technical data, do not use any other supply voltage.
- The unit must only be operated with an electrical installation in accordance with DIN/ VDE 0100, Part 737, 738 and 702. Protection must be provided by a 10 A line protection switch and a RCCD (residual current operated device) having a nominal residual current of 10/30 mA.
- Use only extension cables that are suitable for use outdoors – minimum cross-section 1.5 mm 2 . Cable drums should always be unrolled completely.
- Damaged or brittle extension cables must not be used. ➯ Check the condition of your extension cable each time you start to use the equipment.
ASSEMBLY
Mounting the pressure line see Fig. A
- Screw the connection elbow (7) into the pump outlet.
- Screw the combination nipple (5) into the connection elbow.
- Fix a hose to the combination nipple.
The combination nipple can be trimmed to suit the selected hose connection. Use the largest possible hose diameter.
STARTUP
Safety
CAUTION!
Exclude, by suitable means, that, in the event of a fault in the immersion
pump, consequential damage is caused by flooding.
- Make sure that the immersion pump is standing securely or operate the immersion pump suspended from a rope.
- Make sure there is adequate clearance under the pump.
- Never allow the immersion pump to run against a closed-off pressure line.
- When using in shafts, make sure the size is adequate.
- Always cover the shaft with a secure footplate.
Switching the pump on see Fig. A
CAUTION!
The immersion pump must not draw in any solid bodies. Sand and other abrasive
materials in the conveying medium will destroy the immersion pump.
-
Unwind the connection cable (2) completely.
-
Make sure that the electrical plug connection is mounted in the area safe from flooding.
-
Change the terminal position and adjust the switching points of the float switch (3) individually.
-
Attach the cable on the float switch to the pump housing securely.
➯ Recommended cable length on the float switch approx. 120 mm
Use a suitable plate to ensure secure mounting of the immersion pump on muddy, sandy or stony ground. -
Immerse the immersion pump in the conveying medium slowly. Hold the immersion pump at a slight angle to allow any air to esacape.
-
Insert the mains plug into the plug socket. ➯ The immersion pump switches on automatically using the float switch when a specific water level has been reached, and switches off again if the water drops below the switch-off height.
Switching the pump off
- Remove the mains plug from the plug socket.
Pumping out to residual water level
CAUTION!
Monitor the pump continuously when pumping out to the residual water level and
avoid the pump running dry. Take the pump out of service when the residual
water level is reached by pulling out the mains plug.
HELP IN CASE OF MALFUNCTIONS
CAUTION!
Disconnect the mains plug before any fault rectification work! Faults in the
electrical system must be rectified by a qualified electrician.
The float switch must be operated manually to pump to the residual water level:
- Remove the mains plug from the plug socket.
- Lay the float switch up and fix it in position.
- Insert the mains plug into the plug socket. The pump switches on and starts to feed.
If the water drops below the residual water level, (under 10/40 mm), the pump will draw air in. In this case, the pump must be vented when the water level rises and before using it again.
MAINTENANCE AND CARE
Cleaning the pump
After conveying chlorine-containing swimming pool water or fluids that leave a
residue, the pump must be flushed out with clear water.
- Clean the suction slots on the suction foot if necessary with clear water.
STORAGE
In the event of a risk of frost, the system must be drained completely.
DISPOSAL
Do not dispose of worn-out machines or spent batteries (including rechargeable
batteries) in domestic waste! The packaging, machine and accessories are made
from recyclable materials and must be disposed of accordingly.
Help in case of malfunctions
Malfunction | Possible cause | Solution |
---|---|---|
The motor does not run. | Impeller blocked. | Remove dirt in the suction area. |
Clean with a suitable tool through the opening at the back of the motor
housing.
The thermal protection switch has been switched off.| Wait until the thermal
protection switch on the immersion pump switches on again. Take note of the
maximum temperature of the conveying medium. Have the immersion pump
inspected?
No mains power.| Check the fuses, have the power supply checked by a qualified
electrician.
Float switch does not switch off when the water level rises.| Send the
immersion pump to an AL- KO service facility.
Pump running but does not feed.| Air in pump housing. a| Vent the immersion
pump by holding it at an angle.
Blockage on the suction side.| Remove dirt in the suction area.
Pressure line closed off.| Open the pressure line.
Pressure hose kinked.| Extend the pressure hose.
Feed rate too low| Hose diameter too small.| Use a bigger pressure hose.
Blockage on the suction side.| Remove dirt in the suction area.
Feed head to high.| Observe max. feed head, see technical data!
If the faults cannot be rectified, please contact our customer service department.
WARRANTY
We will address claims for any defects in materials and workmanship during the
statutory period of limitation by means of repairs or replacements of our
choice. The period of limitation is governed by the laws of the country in
which the machine was purchased.
- Our warranty applies only if:
- The machine has been properly handled
- The operating instructions have been adhered to
- Original replacement parts have been used
The warranty is no longer in effect if:
- Efforts have been made to repair the machine
- Technical modifications have been made to the machine
- The machine has not been used for its intended purpose
The warranty does not cover:
- Damage to paintwork through normal use
- Parts subject to wear as indicated in the replacement parts list with a box [xxx (x)]
- Internal combustion engines – separate warranty conditions of the respective engine manufacturer apply
The warranty period begins with the purchase by the first buyer. The warranty period begins on the date that appears on the original purchase receipt. In the event of a warranty claim, please your contact supplier or the nearest authorized customer service centre with this warranty declaration and the purchase receipt in hand. This warranty does not affect the legal warranty claims by the purchaser against the seller.
EU DECLARATION OF CONFORMITY
We hereby declare that this product, in the version brought into circulation by us, complies with the requirements of the harmonized EU guidelines, EU safety standards and product-specific standards.
Product
Immersion pump, electrical
Serial number G3023025| Type
SUB 6500
DRAIN 7000 – 7500
DRAIN 7200| Manufacturer
AL-KO Geräte GmbH
Ichenhauser Str. 14
D-89359 Kötz
---|---|---
Duly authorised person
Andreas Hedrich
Ichenhauser Str. 14
D-89359 Kötz
Kötz, den 11.11.2016
Wolfgang Hergeth
Managing Director
EU guidelines
2014/35/EU
2014/30/EU
2011/65/EU| Harmonised standards
EN 60335-1:2012
EN 60335-2-41:2012
EN 62233:2008
EN 55014-1:2012
EN 55014-2:2016
EN 61000-3-2:2014
EN 61000-3-3:2014 2015
---|---
ETK SUB 6500
Art.-Nr. 112820
ETK DRAIN 7000
Art.-Nr. 112821
ETK DRAIN 7500 / DRAIN 7200
Art.-Nr. 112822 / Art.-Nr. 113507
Country | Company | Telephone | Fax |
---|---|---|---|
GB | Rochford Garden Machinery Ltd. | (+44)1963/828050 | (+44)1963/828052 |
AL-KO GERATE GmbH
I Head Quarter I Ichenhauser St r 14 I 89359 KOtz I
Deutschland Telefon: (+49)8221/203-0 I
Telefax: (+49)8221/97-8199 Iwww.al-ko.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>