ETECH EPB1512 UV Sterilizer and Wireless Charger User Manual
- June 5, 2024
- Etech
Table of Contents
ETECH EPB1512 UV Sterilizer and Wireless Charger User Manual
Thank you for purchasing the Mobile Phone Wireless Charging Sterilizing Box. Please read the instructions carefully before using this product.
Specification
- Product name: Mobile Phone Wireless Charging Sterilizing Box
- Input: 5V/2A; 9V/2A
- Wireless Output: 10W (Max)
- UV light output: 2W (Max)
- Size: 21012062MM
- Weight: 300g Color:
- White Material: ABS+PC
- Rated frequency: 110-20SKHz
- Wireless charge conversion rate: 73%
- Transmission distance: s6MM
Product list
Mobile phone wireless charging sterilizing box x1
Type-C cable (1M) x1
Instructions x1
Dropper x2
Quick Guide
- Plug in the equipped data cable, switch on the power supply, and the product will be in the default wireless charging mode after energizing. the indicator light will be red.
- Put the items that need to be sterilized into the sterilizing box and close the lid. There are two disinfection modes:
- 18-minute disinfection mode: press the button on the top of the lid for a short time, the buzzer will sound “beep-, the green indicator light will light up and enter the 18-minute disinfection mode.
- 30 minutes disinfection mode: press the button on the top of the lid for two short times, then the buzzer will sound “beep” and “beep’, the blue indicator light will light up, and enter the disinfection mode for 30 minutes.
- After the disinfection is completed in 18 or 30 minutes, the built-in buzzer will beep three times continuously.
- Aromatherapy disinfection function: before disinfection, use the equipped straw to drip 2 or 3 drops of perfume into the aromatherapy hole in the box for aromatherapy disinfection.
- Wireless charging function: the mobile phone can be charged wirelessly by placing it in the middle mark of the upper cover. Under the working state of wireless charging, the red indicator light will be on.
- Wireless charging can be operated in the same time with disinfection mode. When working at the same time, the key indicator light will be displayed as ” red and green” or “red and blue”.
Detailed instructions:
Put through power supply
- Before use, please insert the equipped data cable, turn on the power supply, the product will be powered on by default wireless charging mode, the indicator light will be red, it will stay on for 30 seconds in the no-load state, then it will be off and put into standby state.
- if the red light is not on, please check whether the charging cable or charging plug is normal.
- The indicator lights are red/green/blue.
Model
|
Indicator light
---|---
Standby mode (no load after power on)| The red light goes on for 30 seconds
and then goes off into standby mode
Wireless charging mode| The red indicator light kept on
18-minute sterilization mode| The green indicator light kept on
30-minute sterilization mode| The blue indicator light kept on
Wireless charging & 18-minute disinfection mode simultaneously| The indicator
light is red and green
Wireless charging &30 minutes disinfection mode simultaneously| The indicator
light is red and blue
Disinfection
- Place cell phones or other items to be sterilized in a box and close the lid.
- Disinfection mode in 18 minutes: press the button on the top of the cover for a short time, and the built-in buzzer will beep “beep”, the green indicator will be on, and the ultraviolet light in the box will light up for disinfection. When the buzzer continuously beeps “beep” for three times, the disinfection will be finished.
- 30 minutes disinfection mode: press the button on the top of the lid for two short times, and the built-in buzzer will beeps “beep” for two times. The blue indicator light will be in a straight state. At the same time, the ultraviolet light in the box will light up for disinfection.When the buzzer continuously beeps “beep” for three times, the disinfection will be finished.
- Complete disinfection: the whole disinfection process is 18 minutes or 30 minutes. After the disinfection operation is completed, the buzzer will continuously sound “beep ” three times, indicating the automatic end of the operation.
- In the process of disinfection, if you need to stop the operation, please press the button for 3 seconds. After the “beep” sound, the green/blue light will go out and the operation will be stopped. At this point, you can normally open the lid and take out the contents of the box.
- Before disinfection begins, drop 2 or 3 drops of perfume into the aromatherapy hole in the box to carry out aromatherapy disinfection on the items in the box at the same time in the disinfection process.
- Open cover automatically closes uv function.
Magnetic switch
- When the sterilizing box is working, it will automatically close the uv light after opening the cover to prevent harm to human body and eyes.
- When the sterilizing box is working, it will automatically turn on the uv light to sterilize.
Warm prompt
- A maximum of two or three drops of perfume can produce full aromatherapy effect. Do not drop excessive perfume.
- Do not use perfume containing alcohol (such as toilet water, etc.) to avoid adverse effects on the surface of the silicone phone.
- If the upper cover is opened during the disinfection process, the disinfection operation will be suspended temporarily and the ultraviolet lamp will be automatically extinguished to ensure that unnecessary damage will not be caused to the human body outside the box. After the top cover is closed, the UV light is turned on again and the operation is resumed.
- If the product has not been used for a long time, the UV light may have a warm-up process when disinfection begins, it’s about 10 seconds long. After the warm-up, the UV light will automatically light up.
Wireless charging
When the product is powered on, the default mode is wireless charging, and the indicator light is red. In no-load state, the device will be in standby state after 30 seconds. The working state of wireless charging is shown directly by the red indicator light.
- Make sure the top cover of the product is closed, turn the phone’s screen up, and lower the back wireless charging receiving area toward the charging sign (the wireless charging receiving area of the phone is generally in the middle of the back of the phone).
- When the wireless charging module detects the phone normally, it will give a “deep” prompt, indicating that the phone is placed correctly. After waiting for about 1 to 2 seconds, the phone will display a charging prompt on the screen and the phone will start charging. If you don’t hear the beep, try moving the phone to make sure the wireless charging receiving area of the phone is aligned with the charging sign on the top cover
- If the phone is picked up during the charging process, the charging will be terminated; Wireless charging and degerming functions can work at the same time.
Matters needing attention
- Do not disassemble the product by yourself.
- Do not use this product in high temperature or humid environment, please keep away from fire and water.
- This product is only suitable for mobile phone charging which supports wireless charging function.
- If the phone does not have built-in wireless reception function, please purchase a wireless charging receiver separately for use.
- If the mobile phone does not support the wireless quick charge function, it will automatically adjust to the charging efficiency of the mobile phone itself.
- The charging contact surface on the back of the mobile phone shall not contain metal substances, such as iron sheet, ring and metal protective case.
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
FCC RF exposure statement:
The equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. During the operation of device a distance of 15 cm
surrounding the device and 20 cm above the top surface of the device must be
respected.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>