Minoston MS10Z Smart On-Off Switch Instruction Manual
- June 5, 2024
- Minoston
Table of Contents
Minoston MS10Z Smart On-Off Switch
Package Content
- Switch x1
- Wiring x1
- Screws x2
- Faceplate x1
Specifications
Model: MS10Z
Power: 120VAC, 60Hz
Frequency: 908.42 MHz
Maximum Load: 960W Incandescent, ½ HP Motor or 1800W (15A) Resistive
Temperature Range: 32° F~104° F
Indoor use in dry location
FCC / IC
This device complies with part 15 of the FCC and Industry Canada license- exempt RSS standard(s). Operation is subjected to the following two conditions:
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAUTION – PLEASE READ!
This device (MS10Z) is intended for installation in accordance with the
National Electric Code and local regulations in the United States, or the
Canadian Electrical Code and local regulations in Canada. If you are unsure or
uncomfortable about performing this installation consult a qualified
electrician.
CONTROLLING APPLIANCES
Please exercise EXTREME CAUTION when using Z-Wave devices to control
appliances. Reason being is because the appliance you want to control may be
in a separate room and if unintentional behavior occurs (such as a device
turning on or off – either intentionally via schedules, or unintentionally via
network error) this event may lead to a hazardous condition. For these
reasons, please note the following suggestions:
- Do not include Z-Wave devices in Groups or Scenes if they control appliances.
- Do not use Z-Wave devices to control electric heaters or any other appliances which may present a hazardous condition due to unattended, unintentional, or automatic power control
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Important note: To comply with the FCC RF exposure compliance
requirements, no change to the antenna or the device is permitted. Any change
to the antenna or the device could result in the device exceeding the RF
exposure requirements and void user’s authority to operate the device.
WARNING – SHOCK HAZARD
TURN OFF THE POWER to the circuit for the switch and lighting fixture at the
service panel (circuit breaker) prior to installation.
ALL WIRING CONNECTIONS MUST BE MADE WITH THE POWER OFF to avoid personal
injury and/or damage to the switch.
OTHER WARNINGS
Risk of Fire
Risk of Electrical Shock
Risk of Burns
MEDICAL EQUIPMENT
Please DO NOT use this switch to control Medical or Life Support equipment.
Z-Wave devices should never be used to control the On/Off status of Medical
and/or Life Support equipment.
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with other
Z-Wave certified devices from other manufacturers and/or other applications.
All non-battery operated nodes within the network will act as repeaters
regardless of vendor to increase the reliability of the network.
This Device supports Lifeline (association group 1) supporting 1 node for
lifeline communication.
Group 1 must be assigned the Node ID of the primary controller where
unsolicited notifications will be sent. The Z-Wave controller should set this
association automatically after inclusion.
Lieline association only supports the “Device Reset Locally” function. Refer
to the instructions of your controller for any available details on how this
can be set.
Part 1. Installation
Wiring Instructions – A Few Quick Reminders
A quick note before we give out the wiring schematics. Please do not try
installing this device if you are unsure of how electrical circuits operate
within your home. As exciting as it is to have a smart switch installed, it
can be dangerous and even life-threatening if you do not install this
correctly. Please consult a qualified electrician if necessary. With that
said, here are a few other warnings we’d like to point out for your safety:
IMPORTANT!
The fixture controlled by the Z-Wave In-wall Smart Switch must not exceed 960
watts (Incandescent); 1800W (15A) Resistive or ½ HP Motor. The switch is
designed only for using with permanently installed fixtures.
Pre-installation preparation
- Please prepare a flat head screwdriver, a wire stripper, and a voltmeter. Just in case you might need them.
- Before installation makes sure the voltage supply is disconnected. And carefully remove the switch from the switch box.
- The wall box required: 1-gang U.S. wall box. 3½ in deep recommended, 2¼ in deep minimum.
- Wire gauge requirements: use 9 AWG or larger wires suitable for at least 80° C for supplying Line (HOT), Load, Neutral, Ground and Traveler connections.
Installation
-
Turn off circuit breaker
Find your light control in your circuit breaker and turn it off. Make sure the power is off by flipping your switch several times. -
Detach old switch
Unscrew the top and bottom screws of the switch to detach it from the wall.
IMPORTANT! Verify power is OFF to switch box before continuing. -
INSTALL THE WIRES (Refer to the step above the wiring diagram.)
-
Fix the shell (Please use our screws.)
-
Turn on the circuit breaker
Turn on your switch’s power from the circuit breaker. Press the switch several times to check whether it works
PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE!
We will serve you with the most friendly customer services and best product tech support. Contact us: ask@minoston.com now.
IMPORTANT! Please Read.
Line and load must be in the same box for this schematic to work.
if yours is not, please reach out for a custom schematic.
(3-WAY SWITCH WIRING)
For 3-Way setups, please only use an On/Off, 3-Way slave switch (non-dimming).
Note: The Traveler terminal is only used for 3-way wiring .
Please check
which option is best for your 3-way installation.
Part 2. Switch Setup
Operation | LED Status(Blue) | Switch |
---|---|---|
press down | ON ( Default ) | power OFF ( Default ) |
press up | OFF ( Default ) | power ON ( Default ) |
press 2x quickly | / | send scene 1 / scene 2 |
press 3x quickly (see below) | flash quickly | inclusion /exclusion |
press 6x quickly | flash two times | change LED status |
press 7x quickly | flash two times | change locally button function |
press 8x quickly | flash two times | restores state after power failure |
parameter change | flash two times | configuration succeed |
tap-tap and hold 10 seconds | flash quickly | factory default |
Adding your device to a Z-Wave network
Make your controller/hub into the “inclusion” mode, triple press the Up/Down push button quickly to include it in the network.
To exclude and reset the device
Make your controller/hub into the “exclusion” mode, triple press the Up/Down push button quickly to exclude it from the network.
To return your switch to factory defaults
- Tap-tap and hold the upper paddle for at least 10 seconds.
Note: This should only be used in the event your network’s primary controller is missing or otherwise inoperable.
Scene:
Scene 1: Tap-Down-2
Scene 2: Tap-Up-2
Works with Alexa & Google Assistant
It must be connected to a supported hub in order to interact with the Amazon Alexa / Google Home services.
|
FEATURES
- 2 ways of control: Manual & wireless control switch on/off.
- Support 3-way control with regular/ dummy switch(non-dimming switch)–neutral wire required.
- Support 2 customized scene functions.
- Built-in Z-Wave Plus signal repeater /range extender.
- S2 security protocol + the latest 500 series Z-Wave chip.
- OTA for firmware updates.
- Support customized parameter settings.
- Restores the same status after power failure.
---|---
**** WARRANTY
Our Products warrants this product to be free from manufacturing defects for a
period of one year from the original date of consumer purchase. This warranty
is limited to the repair or replacement of this product only and does not
extend to consequential or incidental damage to other products that may be
used with this product. This warranty is in lieu of all other warranties,
expressed or implied. Some states do not allow limitations on how long an
implied warranty lasts or permit the exclusion or limitation of incidental or
consequential damage, so the above limitations may not apply to you. This
warranty gives you specific rights, and you may also have other rights which
vary from state to state.
We are always here for you: ask@minoston.com
The indicator will flashes 2 times after each parameter set successfully.
Parameter| Available settings| Operation
Parameter 1:
Button Function Setting
This parameter can access you to set the up button to turn the light
on/off.| Size=1
Value=0 (Default)
The up button turn the light on and down button turn lights off.
Value=1
The up button turn the light off and down button turn lights on.
Value=2
The up/down button both can changes the state of the light.| Quick press
the switch button 7 times
Please note: the switching of each value is in order, a quick press on
button 7 times will switch once. eg: Switching from value 0 to value 2 needs 2
switching.
Parameter 2:
LED Indicator Status Setting-
This parameter can access you to choose the led indicator to be on when the
switch(light) is on/off, or LED indicator remains on/off all times.| Size=1
Value=0 (default)LED is On when the switch(light) Off and LED is Off when the
switch (light) On.
Value=1
LED is On when switch(light) On and LED is Off when the switch(light) Off.
Value=2
LED is always Off. Value=3
LED is always On.| Quick press the switch button 6 times Please note: the
switching of each value is in order, a quick press on button 6 times will
switch once. eg: Switching from value 0 to value 3 needs 3 switching.
Parameter 4:
Auto Turn-Off Timer.
This parameter can access you to set a timer to make the switch turn off
automatically after the switch turned on.The numberentered as value
corresponds to number of minutes.| Size=4
Values: 0 – 65535 (minutes); Value=0 (minutes) – default setting| Set up on
the hub
Parameter 6:
Auto Turn-On Timer.
This parameter can access you to set a timer to make the switch turn on
automatically after the switch turned off.The numberentered as value
corresponds to number of minutes.| Size=4
Values: 0 – 65535 (minutes); Value=0 (minutes) – default setting| Set up on
the hub
Parameter=7
Association Setting| Size=1 Default = 1
Value=00 – none Value=01 – local Value=02 – 3way Value=03 – 3way & local
Value=04 – z-wave hub
Value= Value=05 – z-wave hub & local Value=06 – z-wave hub & 3-way Value=07 –
z-wave hub & local & 3way Value=08 – timer
Value=09 – timer & local Value=10 – timer & 3-way Value=11 – timer & 3-way &
local Value=12 – timer & z-wave hub
Value=13 – timer & z-wave hub & local
Value=14 – timer & z-wave hub & 3-way| Set up on the hub
Parameter 8:
Restores State after Power Failure
This parameter can access you to set the switch to be on/off after power
failure.
| Size=1 Value=1
The switch is off regardless of the state prior to power failure.
Value=2(default) memory state before power failure
This switch will be return to state prior to the power failure after power is
restored.| Quick press the switch button 8 times Please note: the
switching of each value is in order, a quick press on button 8 times will
switch once. eg: Switching from value 0 to value 2 needs 2 switching.
Association Group: Linking devices:
direct control of other devices within the Z-Wave system network.| Group 1
supports 1 node ID,
Group 2 Supports maximum of 5 node ID’s Association group_1:Z-Wave Plus
Lifeline Association Group 2:Send Basic Set ON / Off| Set up on the hub
Locally Button function:
1: press 1x: turn output ON or OFF
2: quickly press 2x: send scne1/scene2
3: quickly press 3x: inclusion or exclusion
4: quickly press 6x: change Parameter 2
5: quickly press 7x: change Parameter 1
6: quickly press 8x: change Parameter 8
7: Factory reset:click Z-Wave button 2 times quickly, and hold for at least 10
seconds.
Generic Device Class:
0x10 – GENERIC_TYPE_SWITCH_BINARY
Specific Device Class:
0x01 – SPECIFIC_TYPE_POWER_SWITCH_BINAR
Command Classes:
0x5E – COMMAND_CLASS_ZWAVEPLUS_INFO
0x25 – COMMAND_CLASS_SWITCH_BINARY
0x85 – COMMAND_CLASS_ASSOCIATION
0x8E – COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
0x59 – COMMAND_CLASS_ASSOCIATION_GRP_INFO
0x55 – COMMAND_CLASS_TRANSPORT_SERVICE
0x86 – COMMAND_CLASS_VERSION
0x72 – COMMAND_CLASS_MANUFACTURER_SPECIFIC
0x5A – COMMAND_CLASS_DEVICE_RESET_LOCALLY
0x73 – COMMAND_CLASS_POWERLEVEL
0x70 – COMMAND_CLASS_CONFIGURATION
0x5B- COMMAND_CLASS_CENTRAL_SCENE
0x6C – COMMAND_CLASS_SUPERVISION
0x9F – COMMAND_CLASS_SECURITY_2
0x7A – COMMAND_CLASS_FIRMWARE_UPDATE_MD