NONLINEAR LABS C15 Digital Keyboard User Manual
- June 5, 2024
- NONLINEAR LABS
Table of Contents
- NONLINEAR LABS C15 Digital Keyboard
- Power Supply
- Things to avoid doing
- Package Contents
- Device Overview
- Setting up the C15
- Connecting Pedals and mapping Hardware Sources
- Start and Shutdown
- Setting up a Device for the Graphical User Interface Concept
- Wi-Fi Settings
- Introduction to the User Interface
- Updates and Downloads
- C15 Synth Engine Overview
- C15 Synth Engine Detailed
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NONLINEAR LABS C15 Digital Keyboard
Power Supply
Please use only the included power adapter. If this is not possible, obtain a power adapter with the following specifications
- 18 – 20 V DC
- 2.5 A or higher
- Plug: inner contact 2.5 mm (+)
- Plug outer contact 5.5 mm (–)
Do not use a power adapter with different or unknown specifications, as this may electri-cally damage the device! You use a non-original power adapter at your own risk. Nonlin-ear Labs is not liable for damage caused by use of non- original power adapters.
Things to avoid doing
Do not place the C15 on a soft surface (pillow, mattress, etc.) as this can block the circula-tion of air to the device while it is being used. The C15 is an electrical (and electronic) device: do not allow water to come into contact with it. Do not open the C15. The inner parts of the instrument compose an intricate network which is easily damaged and potentially hazardous for inexperienced users. Do not use the C15 in extreme ambient temperatures. Stable performance cannot be guaranteed in very hot or cold conditions. Also avoid high humidity and other difficult conditions. Always wait for the device to shut down completely before you disconnect its power supply. Do not disconnect the power supply during performance. Doing so can cause data to be lost.
Package Contents
C15 Base Unit
C15 Panel Unit
Power Supply adapter and cable
2 Mounting Brackets with Mounting Screws
Printed C15 Quickstart Manual
Unit Connector Cable
USB Flash Drive containing
- The Factory Preset Collection the complete C15 User Reference The flash drive is specially formatted for installing updates. Do not format it and keep it safe.
Device Overview
- Base Unit
- Panel Unit
- Parameter Panel
- Parameter Group
- Parameter Selection Button
- Parameter Selection Indicator
- Multiple Parameter Indicator
- Edit Panel
- Panel Unit Display
- Encoder
- Soft Buttons
- Base Unit Display
- Base Unit Control Panel
- Bende
- Ribbon
- Ribbon 2
- Headphones Connector
- Headphones Volume
- Output Volum
- Panel Unit Fixation Screw
- Mounting Bracket for Panel Unit
- Audio Outputs
- Connectors for Pedal
- USB Connector
- Power Supply Connector
- Powaer Switch
- Unit Connector Cable
Setting up the C15
Mounting the Panel Unit
Ensure the C15 is switched off before following the next four steps
Attach the Mounting Brackets to the Base Unit by hooking and snapping them into place.
Place the Panel Unit onto the installed Mounting Brackets. The two Mounting Screws on the bottom of the Panel Unit fit into the holes at the top of each Mounting Bracket.
Tighten down the Mounting Screws to lock the Panel Unit into place.
Connect Base Unit and Panel Unit with the Unit Connector Cable.
Now the C15 is ready to use and can be switched on. In order to disassemble the paired configuration, undo above four steps in reverse order. The C15’s Base Unit can also be used without the Panel Unit.
Connections
The following external connections are provided by the Base Unit.
The headphone output provides a 6.3 mm stereo headphone socket with separate, preset-independent adjustable headphone level. The headphone socket is suitable for all kinds ofheadphones but we strongly recommend to turn down the level when connecting low-impendance ear plugs. The headphone level is independent from the main output level.
The line output level is adjustable by the potentiometer at the right end of the front bar. The audio output provides two parallel line-level stereo pairs of audio sockets 6.3mm TRS and XLR). Both pairs of sockets provide identical signals. The signals are transformer-balanced and ground-free, therefore in most cases a DI-box is not necessary. Unbalanced and balanced plugs can be connected. When connecting to unbalanced inputs please use unbalanced cables and plugs. Four 6.3 mm pedal sockets are provided for external pedal control. In general, any keyboard controller pedal can be con-nected. However, we recommend continu-ous pedals as they allow for the most nuanced performance.
Connecting Pedals and mapping Hardware Sources
Most factory presets use a mapping as shown below. For more information on Hardware Sources and especially modulation aspects.
he USB connection is used for plugging in the USB flash drive included with the C15. The drive is used for transferring preset Banks and installing Updates. The C15 comes with its own external power adapter, which connects to the power inlet. A small LED next to the inlet indicates the power, boot and shut-down status of the C15.
Start and Shutdown
To turn on the C15, press the power button for around one second. It will take several seconds for the device to boot up and be ready to use. The most recent settings are loaded on startup. To shut down the C15, press the power button again for around a second. The shutdown process takes several seconds, during which it stores the current settings for the next startup, before the device turns off. A small LED next to the power inlet indicates the C15’s status as follows
steady lit | on/normal operation |
---|---|
s lo w blinking | booting |
fast blinking | shutting down |
flashing every 2 seconds | Standby mode |
A flickering LED indicates an irregular operation mode. It means for example the supply voltage is too low. Make sure not to disconnect the power supply while you are using the C15 booting up, performance, shutdown, otherwise its data may be lost.
Setting up a Device for the Graphical User Interface Concept
The C15 is designed for flexible operation and interaction, with the Base Unit
being neces-sary for connections and performance. In addition, the Panel Unit
provides the Hardware User Interface, with access to all parameters, presets
and settings. Finally, the Base Unit also provides a Wi-Fi hotspot for
connection to external devices like smartphones, tablets, laptops and desktop
computers. When connected, the Graphical User Interface can be accessed with a
browser running on the external device. Multiple external devices can be
connected simultaneously, and each can display different fea-tures. However,
only one parameter can be focussed on at a time, which synchronises the
Hardware User Interface with each externally connected device.
Furthermore, the Wi-Fi connection can be used for preset interchange, and
hence the option to back up preset banks to the external device. The C15
Reference is also accessi-ble in the
Graphical User Interface System Requirements
Due to the browser-based implementation of the Graphical User Interface, there are almost no limitations concerning compatibility with operating systems and browsers. Basically, the only system requirements are that the device must be Wi-Fi capable and have a browser installed. However, given the vast variety of devices, operating systems and browsers, optimal per-formance cannot be guaranteed in all cases. Differences between browsers, fast changes in technologies and frequent updates contribute to a complex situation which makes it very hard to say what works best. Nevertheless, our experience in the development of the system enables us to make some recommendations and state some minimal requirements
- The device should have at least a 1 GHz processor and 2 GB RAM.
- The device’s display should support multi touch, or a mouse should be connected. A connected or integrated keyboard is useful for using the Graphical User Interface.
- The device should have at least a 7 diagonal display.
- Although the choice of browser is completely up to the user, currently the best performance is given by Google Chrome.
- If you encounter problems with your setup, try to restart your device or change to another browser or device. If not, or if the problem won’t go away, please contact us directly for help. We appreciate feedback and user reports and will do our best to solve your problem as soon as possible.
Wi-Fi Settings
To set up a well defined Wi-Fi connection, enter the Setup Menu on the Hardware User Interface (Setup Button) and navigate to System Info. Here, all relevant aspects of the Wi-Fi connection are listed:
Device Name
You can name your C15 instrument by focussing on the Device Name entry and pressing Enter to access the Rename Screen. Once the name is set, an SSID will be generated. The SSID is composed of a prefix NL-C15 and the name you just gave to the instrument.
SSID
A Wi-Fi network with the same name as the SSID will be displayed when you scan for available networks on your external device. Changing the name of your C15 instrument will immediately generate a new SSID, meaning you will likely need to reconnect your external device to the C15 network.
Passphrase
The network connection is secure, so a passphrase (WPA2 key) is needed to establish a connection. To connect to the network with your external device, use the displayed passphrase to confirm. The pass phrase can be randomly generated or edited manually. To do this, please select the “Passphrase” entry, press Enter and select the appro- priate command. If you suspect that the passphrase is no longer secure because it has been shared with someone, a new passphrase should be generated.
Website Address 192.168.8.2
Once the connection is established, please enter this address into your
browser’s address bar and the Graphical User Interface should appear in your
browser.The Wi-Fi connection can also be disabled to provide a more secure
setup and prevent anyone else controlling the device remotely. This may be
especially useful when perform-ing live. Enter the Setup Menu (Setup Button)
and navigate to Device Settings. Find Enable/Disable WiFi entry and change the
setting.
Introduction to the User Interface
Edit Panel
Base Unit Control Panel
Loading a Preset
Open the Preset screen by pressing Preset 2. Select a preset by the Encoder 20 or Dec/ Inc 15, 16 When Direct Load is on, the preset will be loaded instantly, otherwise Enter 12 will load the preset. Toggle “Direct Load” mode by pressing Soft Button 7. Other preset banks can be selected by the two Soft Buttons 5,6 . Pressing the “Bank” Soft Button 4 redi-rects to the Preset screen in Bank mode, where banks can be selected by the Encoder20.or Dec/Inc 15, 16 and presets can be selected by the Soft Buttons 5,6.
Storing a Preset
Pressing Store 8 opens the Preset screen in Store mode. With the Soft Button 7 you can choose Append, Overwrite or Insert, creating a new preset at the end of the list (append), behind the selected preset (insert), or overwriting the data of the selected preset (overwrite).The store location can be changed by the Encoder 20 or Dec/Inc 15, 16. Other preset banks can be selected by the two Soft Buttons 5,6 .To finish the store process press Enter 11. Pressing Store 8 will cancel the process. When storing a new preset the Rename screen will open, so you can edit the label.
Edit
Certain elements include additional functions which will be provided when pressing Edit 12. Examples of additional functions are Rename, Edit Info (for presets, banks and Macro Controls) as well as Copy Paste, or Delete for presets and banks.
Init Sound
Pressing Sound 3 will invoke the Sound screen, providing options to further manipulate the current sound. Press Soft Button 4 to select and then the Enter 11 button to recall the Init sound. Every parameter will load its default value.
Note that the factory default values for Output Mixer component levels are zero, meaning that the initial sound is silent.
Adjusting a Parameter
The parameters of the synth engine can be accessed by the 96 selection
buttons. The LED of the pressed button will light up. Dots below the LED
indicate if additional parameters can be selected by pressing the button
multiple times. The stack of selectable parameters is also shown at the right
side of the display 19. You can step through it by using the Soft Button as
well.
The selected parameter can be adjusted by the Encoder 20 and Dec/Inc 15, 16.
Pressing Default 14 recalls the default value. The resolution can be toggled
between coarse and fine mode by pressing Fine10 .
Macro Controls
Up to six Macro Controls (MC) can be assigned to modify the sound of a preset. You can access them by their Selection Buttons. Their labels and info can be defined per preset. For the selected MC the LEDs of the target parameters will blink. The MC can be adjusted like a parameter. It can be influenced by Hardware Sources as well, as shown by the eight small bar graphs at the right end of the display 19.
Assigning a Macro Control to a Hardware Source
Macro Controls can follow movements of multiple Hardware Sources. There are eight Hardware Sources provided by the C15: four connectors for external pedals, two Ribbons, the Bender and monophonic Aftertouch. In order to assign a Hardware Source to a selected Macro Control, use the “HW Sel” Soft Button 5 and select the desired Hard ware Source by using the Encoder 20 or Dec/Inc 15, 16. The Soft Button 7 can also be used to select a Hardware Source. For the selected Hardware Source use the HW Amt Soft Button 6 to adjust its influ-ence on the MC.
Assigning a Parameter to a Macro Control
The most significant parameters can follow movements of a Macro Control. In order to assign the selected parameter to a Macro Control, use the MC Sel Soft Button 5 and select the desired Macro Control by using the Encoder 20 or Dec/Inc 15, 16. When a Macro Control has been chosen, use the MC Amt Soft Button 6 to focus on the modulation amount and adjust the amount like a parameter. The modulation amount of a parameter specifies intensity and direction of its movement, following the assigned Macro Control. Info Press Info 9 to get information about a parameter, Macro Control, preset or bank. The infos of Macro Controls, presets and banks are user definable.
Undo / Redo
For un-doing and re-doing editing steps use Undo/Redo 17,18. Pressing both of them at the same time will open the undo history in the display19.
Base Unit Functionality
The Base Unit provides four operational modes which can be selected with Mode.
In Play mode, the display shows the labels of the Macro Controls to which the Ribbons are assigned or not assigned. The letter a or r indicates if the touch strip works as an absolute or relative input device. The last touched Ribbon is indicated by < and its input mode can be switched with Funct With -/+ you can shift the keyboard range up and down by octaves. Holding one button while pressing the second will shift the pitch by semitones.
In Edit mode, Ribbon 1 will be assigned to the currently selected parameter as additional editing tool, while Ribbon 2 remains in play mode. In Bank mode, banks can be navigated with -/+ while Funct serves as Direct Load (DL) switch when held for a second.In Preset mode, presets can be navigated with -/+ . When “Direct Load” is off and an arrow is shown, Funct will load/reload the selected preset. Direct Load (DL) can be toggled by holding Funct for a second.
Updates and Downloads
Please save your preset banks before installing the update. The most convenient way is to use the menu entry Save all Banks as Backup File in the graphical user interface or with Backup and Save all Banks in the Setup menu in the Panel Unit display. Do not ower off the C15 ring the update inst lation! An i rruption of the power in this phase can cause irreversible damage.
Steps to proceed
-
The latest installer is offered on: www.nonlinear-labs.de/support/updates/updates.html
-
By clicking its button you download the file “nonlinear-c15-update.tar” to your com-puter. You will also find a PDF file Whats New? on the website to inform you about the latest feature updates and bug fixes.
-
Your computer might offer to unpack this type of file. Please make sure that the file is NOT unpacked or changed in any way.
-
Copy the file nonlinear c15-update tar to the root folder of the USB memory stick that was delivered with the C15.
-
Other memory sticks will only work if they have the FAT32 format.
-
Switch off the C15 and plug the memory stick into the USB connector at the backside of the C15.
-
Switch on the C15. During the update process the small display will show Updating messages.
-
When the update is finished, the display will show
- Updating C15 DONE
- Please restart
- Please switch off the instrument, remove the memory stick and switch it on again.
-
If you update from version 21-02 you might get the error message Updating C15 FAILED during the installation. In this case the installer needs to be run a second time. Please restart the C15 without removing the USB stick. Now the update should be successful
-
After a successful update the file on the memory stick is automatically renamed to nonlinear-c15- update.tar-copied. Please delete this file before using the stick for another update.
All downloaded update files have identical names nonlinear c15 update ar. -
This is the file name required by the C15 to detect an update on the memory stick. If there is an earlier update file with this name in the download folder of your browser, the name of the new update will be modified e.g. by adding -1.
-
Therefore please check if the file has been renamed and restore the original name.
-
It is recommended to remove all C15 update files from the download folder.
-
If you want to store different updates on your computer, please keep them in separate folders or rename them, so that you can identify them later.
-
You can check the current software versions in the System Info section of the Setup.
-
For this press the Setup button on the Edit Panel or the Setup entry in the view menu of the graphical user interface and select “System Info”. Here you find the Software Version.
-
It shows the release date as year and week in the format YY-WW e.g. 20-40 – week 40 in year 2020.
-
If a FAILED message appears in the display, the update was not successful. In this case please repeat the installation.
-
Rename the installer file to the original name nonlinear-c15-update.tar, plug in the USB stick and start the C15 again.
-
If this is without success please contact us. On the USB stick you will find a log file nonlinear-c15-update log txt which you can send us to help us analyzing the problem.
C15 Synth Engine Overview
C15 Synth Engine Detailed
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>