Marshall 51457 52 Inch Indoor Ceiling Fan Owner’s Manual

June 5, 2024
Marshall

Marshall-logo

Marshall 51457 52 Inch Indoor Ceiling Fan

PACKAGE CONTENTS

Unpack your fan and check the contents. You should have the following items:

  1. Canopy
  2. Canopy Cover
  3.  Mounting Bracket Screw (x4)
  4. Mounting Bracket
  5. Downward
  6. Downward Clip
  7. Downward Pin
  8. Yoke Cover
  9. Set Screw (x2)
  10.  Closemount Screw (x3)
  11. Motor Assembly
  12. Fitter Plate
  13. Fitter Plate Screw (x3)
  14. Light Pan
  15. Light Pan Screw (x3)
  16. Light Kit
  17. Finial
  18. Finial Cap
  19. Light Cage
  20. Owner’s Manual
  21. Hardware Kit
  22. Medallion (x5)
  23. Blade Arm (x5)
  24. Blade (x5)
  25. E26-base LED Bulb (x2)
  26. Motor Screw (x10)
HARDWARE CONTENTS
  1.  Blade Screw (x15)
  2. Blade Washer (x15)
  3. Wire Connector (x3)
  4. Pull Chain Extension (x2)
  5. Secondary Support Screw
  6. Support Washer
  7. Secondary Spring Washer
  8. Blade Balancing Kit

Note: Some extra hardware has been included. The quantity listed above is the number required for installation.
Marshall-51457-52-Inch-Indoor-Ceiling-Fan-02

TOOLS REQUIRED (not included)

Marshall-51457-52-Inch-Indoor-Ceiling-Fan-03

Tools required for assembly: Electrical tape, Phillips Screwdriver, Pliers, Safety Glasses, Step Ladder, Wire Cutters and Wire Strippers
Helpful Tools: AC Tester Light, Tape Measure, and Wiring Handbook

DIMENSION REFERENCE
  • A. 16.98 in. B. 11.04 in. C. 7.17 in. D. 5.13 in.

MOUNTING OPTIONS

Three Mounting Options

Marshall-51457-52-Inch-Indoor-Ceiling-Fan-05Choose one of the following mounting options:

  • Closemount Installation is best suited for ceilings lower than 8 feet. It does not utilize the downward. downward Mount is best suited for ceilings 8 ft. or higher.
  • For taller ceilings you may want to use a longer downward(not included).
  • Angled Ceiling Mount is best suited for angled or vaulted ceilings. A longer downward is sometimes necessary to ensure proper blade clearance from the ceiling.
  • If using the angle mount, check to ensure the ceiling angle is not steeper than 16°.

SAFETY INSTRUCTIONS

READ ALL SAFETY INFORMATION AND INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN INSTALLING THE FAN AND SAVE INSTRUCTIONS.
CAUTION:

  • All set screws of the fan must be checked and retightened where necessary before installation.
  • To reduce the risk of personal injury, do not bend the blade brackets when installing the brackets, balancing the blades or cleaning fan. Do not insert foreign objects in between rotating fan blades.
  • Before changing the fan direction, turn off the fan and wait for the fan blades to stop completely.
  • The safeguards provided by these safety instructions and by the separate installation instructions are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and care are factors which can not be built into this product. These factors must be supplied by the person(s) installing, caring for and operating the fan.
  • The fan weight is Net Weight: 17.71 lbs (8,03 kg). Be sure the outlet box (not included) is securely attached to the building structure and is marked “Acceptable For Fan Support”. Failure to do so can result in serious injury.
  • This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device (if applicable).
  • CAN ICES-005 (B) / NMB-005 (B)

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver
  • Connect the equipment into and outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Please note changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
HKC-US
3350 Player’s Club Parkway, #225
Memphis, TN 38125
1-877-706-3267

WARNING:

  • To avoid risk of electric shock, be sure to shut off power at the main fuse or circuit breaker box before installing or servicing this fixture. Turning off the electrical power by using the light switch is not sufficient to prevent electrical shock.
  • To reduce the risk of injury, install the fan so that the blades are at least 7 feet (2.1 Meters) above the floor and at least 18 inches (0.5 Meters) from the tip of the blades to the wall.
  • To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “acceptable for fan support” and use mounting screws provided with the outlet box.
  • The installation has to be in accordance with the national electrical code, ansi/nfpa 70-1999 and local codes. If you are unfamiliar with the methods of installing electrical wiring, seek the services of a qualified licensed electrician.
  • Using a full-range dimmer switch to control fan speed will cause a loud humming noise from the fan. To reduce the risk of fire or electric shock, do NOT use a full-range dimmer switch to control the fan speed.

ASSEMBLY INSTRUCTIONS

  1. Turn OFF the electrical power at the main fuse or circuit breaker.
    DANGER: Failure to disconnect the power supply prior to installation may result in serious injury or death.

  2. Remove the mounting bracket by removing the two mounting bracket screws from the round holes in the canopy. Then loosen the other two mounting bracket screws from the J-slots. Retain the mounting bracket screws for later. Install the mounting bracket to the outlet box (not included) using the screws and washers provided with the outlet box.
    Warning: To reduce the risk of fire electric shock, or personal injury, mount to the outlet box marked “acceptable for fan support” and use the mounting screws and washers provided with the outlet box.

  3.  Remove the ten motor screws from the underside of the motor and save for blade arm installation.

  4. CLOSEMOUNT INSTALLATION (Optional) –

    • Remove the three Phillips-head closemount screws from the top of the motor assembly.
    • Remove the canopy cover from the bottom of the canopy.
    • Align the holes in the bottom of the canopy with the screw holes in the top of the motor assembly. The larger holes in the canopy will encompass the three pre-installed screws.
    • Secure the canopy to the top of the motor assembly with the three closemount screws.
    • Hang the fan on the hook of the mounting bracket. Proceed to Step 9.
  5. DOWNROD MOUNT – Remove the downward clip and downward pin from the downward. Then, loosen but do not remove the two set screws at the top of the yoke.

  6. Feed the wires and braided cable coming from the yoke through the yoke cover, canopy and downward.

  7. Insert the downward into the yoke and reinstall the downward pin and downward clip. Then retighten the two set screws.
    Note: With wiring extending out of the downward, measure 8 inches of lead wire and cut the excess wire with wire cutters (not included). Then strip 1/2” of insulation from the end of each wire.
    WARNING: Do not cut braided cable.

  8. Lift the downward into the mounting bracket. Rotate the downward until the tab in the mounting bracket is seated in the slot in the downward ball.
    WARNING: The fan and/or downward should not rotate in the mounting bracket, if installed correctly. Failure to align the slot in the downward ball with the tab on the mounting bracket may result in fan falling causing serious injury or death.
    SECONDARY HANGING SYSTEM
    For installation in the United States: Building codes in the U.S.A. do not require installation of a Secondary Hanging System. If desired, the braided cable can be cut and removed using wire cutters (sold separately). Skip to Step 12.
    For installation in Canada: In compliance with building codes in Canada, installation of the Secondary Hanging System is required.

  9. Feed the loop of the braided cable, preassembled to the motor assembly, up through the outlet box mounted in the ceiling.

  10. Install secondary support screw, secondary spring washer, and support washer partly into the side of the brace installed in the ceiling. Then lift the braided cable up and over the ceiling brace and place the open loop of the braided cable around the secondary support screw. Note: The ceiling support brace may not be accessible from below. If not, it must be accessed from above. Important: The braided cable must make a complete circle around the support brace to secure the fan.

  11. Tighten the secondary support screw securing the braided cable.

  12. Use wire connectors to connect the fan wires to the power supply wires according to the wiring diagram and the following instructions:
    Connect the white wire from the fan to the white (neutral) supply wire.

    • Connect the black and blue wires from the fan to the black (hot) supply wire.
    • Connect the green wire from the downward and mounting bracket to the bare/green (ground) supply wire. Note: The downrod is not used for closemount installation, so there will only be two green wires to connect.
      Note: If a second hot/power wire is available from the outlet box, connect it to the blue (light power) fan wire for separate fan and light switches.
      Important: After the connections have been made, the wires should be turned upward and pushed carefully
      up into the outlet box. Place the black and white wire connections on opposite sides of the outlet box.
  13. Align the canopy over the loosened mounting bracket screws. Place the J-slots of the canopy onto the mounting bracket screws and rotate clockwise. Secure the canopy with the two previously removed mounting bracket screws. Tighten all the mounting bracket screws securely.

  14. Partially insert three blade screws along with blade washers through the blade, blade arm, and into the medallion. Tighten each blade screw starting with the one in the middle. Repeat this step for the remaining blades.

  15. Insert blade arm through slot in the motor assembly. Align the holes of blade arm with the two motor screw holes in the underside of the motor assembly. Secure with previously removed motor screws. Repeat this step for the remaining blades.

  16. Remove one of the three fitter plate screws preassembled to the fitter plate from the round hole and loosen the other two but do not remove. Align the slotted holes in the light pan with the loosened screws in the fitter plate. Turn light kit clockwise and replace the previously removed fitter plate screw. Tighten all screws.

  17. Remove the three light pan screws from the top edge of the light pan. Then, connect the 9-pin connectors from the light pan to the 9-pin connectors from the light kit. Then, use the three previously removed light pan screws to secure the light kit to the light pan.

  18. Install the E26-base LED bulbs into the sockets of the light kit.

  19. Remove the finial and finial cap from the threaded rod at the bottom of the light kit. Lift the light cage over the threaded rod and secure with the finial cap and finial.

  20. Attach pull chain extensions to the pull chains.
    Note: The pull chain in the center of the light kit controls the light.
    Installation is complete. Turn ON the electrical power at the main fuse or circuit breaker.

OPERATING INSTRUCTIONS

  1. Using a ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort.
    In warmer weather, push the reverse switch left which will result in downward airflow creating a wind chill effect.
    In cooler weather, push the reverse switch right which will result in upward airflow that can help move stagnant, hot air off the ceiling area.
    Important: Wait for the fan to stop before moving the reverse switch. The reverse switch must be set either completely left or right in order for the fan to function correctly. If the reverse switch is set in the middle position, the fan will not operate.

  2. The fan pull chain has four positions to control fan speed. One pull is HIGH, two is MEDIUM, three is LOW and four turns the fan OFF. The light pull chain turns the light ON and OFF.

TROUBLESHOOTING

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check the Troubleshooting section below. If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-706-3267, 8 a.m.-5 p.m. Central, Monday-Friday.
WARNING: To reduce the risk of fire, electrical shock or personal injury, shut off the power supply to fan before you begin any maintenance tasks.

  • PROBLEM 1:
    • Fan does not start:
    • SUGGESTED REMEDY
      • Make sure that the wall switch is turned ON.
      • Check main and branch circuit fuses or circuit breakers.
      • Check all wire connections from household supply wires to the fan.
    • Make sure forward/reverse switch pushed completely up or down. Fan will not operate when switch is in the middle.
  • PROBLEM 2:
    • Fan is noisy:
    • SUGGESTED REMEDY
      • Make sure all screws in motor assembly are snug, but not overtightened.
      • Make sure the screws that attach the blade arms to the motor are tight.
      • Make sure wire connectors are not rattling against each other or against the interior wall of the switch housing.
      • Make sure wire connectors are not rattling against each other or against the interior wall of the canopy.
      • Some fan motors are sensitive to signals from Solid State variable speed controls. DO NOT USE a Solid State variable speed control.
      • Ensure fan does not wobble excessively (see Fan wobbles solutions below).
  • PROBLEM 3:
    • Fan wobbles:
    • SUGGESTED REMEDY
      • Ensure the mounting bracket is tightened securely to outlet box and outlet box is mounted firmly to ceiling joist.
      • Ensure all blades are screwed firmly into blade arms.
      • Ensure all blade arms are tightened securely to motor.
      • Switch one blade with a blade from the opposite side. Or balance the fan using the blade balancing kit.
      • If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute the weight and possibly result in smoother operation.
  • PROBLEM 4:
    • Light does not work:
    • SUGGESTED REMEDY
      • Check for loose or disconnected 9-pin and/or single-pin connectors in switch housing or light kit.
      • Ensure the blue wire from fan is connected to hot power supply wire.
      • Check for faulty light bulbs.
      • Ensure total wattage of bulbs does not exceed 180 watts (for incandescent bulbs only).

LIMITED LIFETIME WARRANTY

To obtain Service, please contact the Service Department:
1-877-706-3267, 8 a.m.-5 p.m. Central, Monday-Friday.

  • Model Name: 52” Ceiling Fan
  • Model No: 51457 – Matte Black 51458 – Pewter

Set forth below, the manufacturer, Hong Kong China Electric appliance Company (HKC) warrants the fan motor for this ceiling fan to be free from defects in workmanship and material for the life of the product. Also, subject to the limitations below, HKC warrants all ceiling fan parts (“ceiling fan parts” excludes the motor and parts made in whole or in part with glass) to be free from defects in workmanship and material for a period of one year after the date of purchase by the original purchaser at retail. All claims must be made by the original purchaser, whether such purchaser purchased the product through a store or contractor. Ceiling fan part defects must be reported within the first year from the date of purchase. Parts made in whole or in part with glass and the finishes of metal and other surfaces are not warranted. Purchasers are responsible for all costs of removing and reinstalling the product. Any damage to any part caused by ordinary wear and tear, accident, misuse, or improper installation, is not covered by this warranty. HKC assumes no responsibility whatsoever for fan installation. Any service performed by a non-licensed electrician will render the warranty invalid.
HKC’s sole responsibility shall be to repair or replace the motor, parts, or product within the terms stated above. HKC shall not be liable for any loss or damage of any kind, including any incidental or consequential damages resulting directly or indirectly, from any breach of warranty, express or implied, or any other failure of this product. Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you.
If the original purchaser ceases to own the fan, this warranty is voided.
Should the purchaser encounter a problem with your fan related to defects in workmanship or materials within the warranty period associated with the defective part, HKC agrees to replace the defective part without charge, or at its option, to replace the ceiling fan with a comparable or superior model.
HKC’s warranties are limited to the written warranties set out in this HKC ceiling fan limited lifetime warranty. All other express and implied warranties, including, without limitation, the implied warranty of fitness for a particular purpose and the implied warranty of merchantability are disclaimed. Some states do not allow the disclaimer of implied warranties, so this disclaimer may not apply to you.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals