JBC PHNK Nano Preheater Set Instruction Manual

June 5, 2024
JBC

JBC PHNK Nano Preheater Set-logo

JBC PHNK Nano Preheater Set

JBC PHNK Nano Preheater Set-prod

This manual corresponds to the following references:

  • PHONE-1KA (120V)
  • PHONE-2KA (230V)
  • PHONE-9KA (100V)

Packing List

JBC PHNK Nano Preheater Set-fig1

The following items are included:

Features and Connections

Preheater UnitJBC PHNK Nano Preheater Set-fig2

ConsoleJBC PHNK Nano Preheater Set-fig3

SupportJBC PHNK Nano Preheater Set-fig4

Height Adjustment

Nano PCB Support allows adjustment for 3 heights between the PCB and the Heating Area of the Preheater unitJBC PHNK Nano Preheater Set-
fig5

To change the height to the highest level, proceed as follows:JBC PHNK Nano
Preheater Set-fig6

  1. Remove the 4 clamp knobs and the 4 black rubber caps.
  2. After removing both guides, turn 180° the guide supports.
  3. Place the guides, the rubber cups and adjust the Sliding clamp knobs again.

Fast PCB Replacement

Nano PCB Support lets you replace PCBs of the same batch fast and easily. Use the sliding guides to change the PCBS.
Removing PCBJBC PHNK Nano Preheater Set-fig7
Loosen one sliding guide, pull back and ift out the PCB.

Placing another PCBJBC PHNK Nano Preheater Set-fig8
Position it and tighten the sliding guide knobs.

Work Screen

JBC PHNK Nano Preheater Set-fig9

The Console offers an intuitive user interface that provides quick access to station parameters.

Available languages: English, Spanish, German, French, Italian, Portuguese, Japanese, Chinese, Russian, and Korean.
Troubleshooting
Station troubleshooting is available on the product page at www.jbctools.com

System notifications (Status Bar)

  • USB flash drive is connected.

  • The station is controlled by a PC.

  • The station is controlled by a robot.

  • Station software update.
    Press INFO to start the process.

  • Warning.
    Press INFO for failure description.

  • error. Press INFO for failure description, the type of error and how to proceed.

Setting Thermocouples Function
Select Thermocouples from the Work mode menu to set them up. The thermocouples (TC) can work in three different ways depending on what is needed.

  • Control: the unit maintains the selected temperature.
  • Protection: the Heater Unit stops if the TC reaches the selected temperature.
  • Info: the IC temperature is shown on the work screen.

The TC1 is always working in Control mode for the Temperature mode as well as for Profiles mode. The temperature of each TC can also be selected from the work screen.

Recommended Guidelines

  1. Place the control thermocouple as near as possible to the component being worked on.
  2. If there are any sensitive components, use a thermocouple as protection. You can select the protection temperature in the thermocouples menu. If the selected temperature IS reached, the Heater Unit will stop the process and a warning message will be shown.JBC PHNK Nano Preheater Set-fig11.
  3. IPC does not recommend exceeding ramp-up rates over 3 – 4C/ Sec (5 – F/ sec) So as to reduce the risk .of thermal stress on the PCB.

Work Mode

Temperature Mode:
Select Temp. mode from the Work mode menu. In this mode the heater unit maintains the selected temperature for the TC1 thermocouple as long as the other TC’s do not reach the control/protection temperature limit.JBC PHNK
Nano Preheater Set-fig13

Working within the Temperature Mode the maximum heating rate value (Max Rate) can be defined (1).

This Function allows you to set a maximum value Tor the temperature increase per second when heating The maximum heating rate value can be set between 0.1°C/s and 2.0°C/s (2) or “None” if this function is not desired.

Power Mode:
Select Power mode from the Work mode menu. In this mode the heater unit maintains the selected power as long as the thermocouples do not reach the control/protection temperature limit. JBC PHNK Nano Preheater Set-
fig16

Profile Modes
Select Profile Mode from the Work Mode Menu. In this mode the heater unit regulates the temperature of the TC1 thermocouple according to the selected profile as long as the other TCs do not reach the control/protection temperature limit.

Teach Profile
For repetitive jobs you running profiles without the thermocouple (TC). In order to do so, the Teach profile mode has to be executed before running any profile. It can be executed from the Work mode menu if the Profiles mode is selected. Once the profile has been run to the end, the system has all the process data which you can save.  Once it is saved, you can run this profile without connecting the thermocouple (TC). The heating process will be the same as long as the same working conditions are respected. The profiles which already have the data from the Teach profile are marked with this symbol These profiles can be run either with or without the Thermocouples. It can be chosen from the Profiles mode work screen:

Profile Editor
The Profile editor can be opened from the main menu or from the Profíles mode work Screen by pressing the OR’ button. In this mode you can edit as many as 25 profiles of temperature. JBC PHNK Nano Preheater Set-
fig18

JBC Set Profiles
Their are3 profiles predefined by JBC: A, Band C. The difference between them is the number of steps: 2,3 or 4. The thicker your PCB is and the more layers it contains, the more steps are needed to obtain gradual warming. These profiles are not modifiable but can be used as a template to create your own profiles.JBC PHNK Nano Preheater Set-fig19

Process Analysis
By pressing Graphics in the main MENU, the temperature of TC1 thermocouple and power figures in real time are displayed.JBC PHNK Nano Preheater Set-
fig20

System Notifications

The following icons will be displayed on the screen’s status bar.

  • USB flash drive is connected.

  • The station is controlled by a PC.

  • The station is controlled by a robot.

  • Station software update.
    Press INFO to start the process.

  • Warning.
    Press INFO for failure description.

  • Error.
    Press INFO for failure description, the type of error and how to proceed.

Files

Export Graphics
Insert a USB flash drive into the USB-A connector tO save your soldering process in csv format.
Export/ Import Profiles
Insert a USB flash drive into the USB-A connector to export/ import profiles.

Update the Station SoftwareJBC PHNK Nano Preheater Set-
fig22

  1. Download the JBC Update File from www.jbctools.com/software.html and save it on a USB flash drive. (Preferably one with no other files).
  2. Insert the USB flash drive to the console. The icon is diplayed while updating.

Working with Pedal
Press the pedal to start heating and press again to stop as if it was the button on the console. Once the Work Mode is set, the Heater Unit can work without the console using the pedal.JBC PHNK Nano Preheater Set-
fig23

Maintenance

Before carrying out maintenance or storage, always allow the equipment and the support to cool down.

  • Check periodically that the Pre Heater and the Support are clean.
  • Use a damp cloth when cleaning. Alcohol can only be used to clean the metal parts.
  • Only if it is absolutely necessary and if cleaning with isopropyl alcohol (IPA) is not enough, it is recommended to use a scraper to remove dirt in the glass area.
  • Replace any defective or damaged parts. Use original JBC spare parts only.

Safety

It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.

  • Do not use the units for any purpose other than PCB preheating. Incorrect use may cause fire.
  • The main cable must be plugged into approved bases. Make sure that it is properly grounded before use. when unplugging it, hold the plug, not the wire.
  • The temperature of accessible surfaces may remain high after the unit is turned off. Handle with care.
  • Do not leave the appliance unattended when it is on. Do not cover the ventilation grills. Heat can cause inflammable products to ignite.
  • Heat can cause inflammable products to ignite even when out of sight.
  • Be careful with the remains of liquid tin. In contact with skin, ít can cause burns.
  • Avoid flux coming into contact with skin or eyes to prevent irritation.
  • Be careful with the smoke produced when soldering.
  • Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm.
  • The appliance can be used by children over the age of eight as well as persons with reduced physical, sensory or mental capabilities or lacking experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved. Children must not play with the appliance
  • Maintenance must not be carried out by children unless supervised.

Specifications

PINK
Nano Preheater Set

  • Ref.: PHNE-9KA 100V. Input 100V 50/60Hz Fuse 4A
  • Ref.: PHNE-1KA 120V. Input 120V 50/60Hz Fuse 4A
  • Ref.: PHNE-2KA 230V. Input 23OV 50/60Hz Fuse 2A

Nano Preheater Unit

  • Maximum Power: 300 W
  • Heating Area (L x W): 108 x 70 mm / 4.25 x 2.75 in (1 zone)
  • Ambient Operating Temperature: 10 – 50 ºC / 50 – 122 ºF
  • Temperature Range: 50 – 250 °C / 120 – 482 ºF
  • Temperature Measurement: Thermocouple type K
  • JBC Set Temperature Profiles: 3 profiles (2, 3 or 4 steps)
  • User Profiles: 20 (up to 6 steps for each)
  •  Maximum Work Time: 600 min or indefinite
  • Dimensions / Weight: 179 x 165 x 41.5 mm / 1.2 kg (L x W x H) 7.04 x 6.5 x 1.63 in / 2.6 lb

Nano PCB Support

  • Weight: 1.9 kg / 4.2 lb
  • Dimensions (Low Position): 238 x 237 x 75 mm (L x W x H) 9.4 x 9.3 x 3 in
  • Dimensions (High Position): 238 x 237 x 96 mm (L x W x H) 9.4 x 9.3 x 3.8 in

Nano Preheater Set

  • Total Net Weight: 3.1 kg / 6.83 lb
  • Total Package Dimensions / Weight: 280 x 280 x 164 mm / 4.2 kg (L x W x H) 11.02 x 11.02 x 6.45 in / 9.3 lb

Warranty

JBC’s 2-year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labor.  The warranty does not cover product wear or misuse.  In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it waspurchased.Get 1 extra year of JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase. This product should not be thrown in the garbage. In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals