Caple CCH601SS Wall Chimney Hood Stainless Steel Instruction Manual
- June 5, 2024
- caple
Table of Contents
Caple CCH601SS Wall Chimney Hood Stainless Steel
INTRODUCTION
Thank you for choosing this Caple extractor hood.
To ensure that you get the best results from your new extractor, we strongly
suggest that you read this instruction manual thoroughly before use. If
treated with care, your Caple extractor should give you years of trouble-free
use.
To register ownership, please ensure you complete and return the guarantee
card supplied with the appliance or visit www.caple.co.uk and register here.
This instruction manual is designed to provide you with all the required
information related to the installation, use and maintenance of the appliance.
This hood is designed to extract unpleasant odours from the kitchen; it is not
intended to extract steam. In order to operate the unit correctly and safely,
please read this instruction manual carefully before installation and use.
The cooker hood uses high quality materials and is made with a streamlined
design. Equipped with an electric motor and centrifugal fan, it provides
strong extraction with low noise. It also features non-stick grease filters and
an easy installation.
IMPORTANT
- This appliance must only be used for the purpose it is intended. Other types of use are not permitted and may prove dangerous. Caple will not be held liable for any damage caused by the incorrect use of the appliance.
- Do not use any accessories or attachments not recommended by Caple as this may result in fire, electric shock or injury.
- To protect against fire, electrical shock and injury to persons, do not immerse cords or plugs in water or any other liquid.
- Never touch the appliance with wet or damp hands.
- Never pull the power cable as you could damage it.
- If the appliance is faulty, do not attempt to repair it. Isolate it from the mains electric supply and contact Caple Service either by phone 0117 938 7420 or email service@caple.co.uk
- Keep all packaging (including plastic bags, polystyrene foam etc) out of the reach and away from children.
- Do not rest large or unstable objects on any part of the appliance.
IMPORTANT
Caple cannot be held responsible for injuries or losses caused by incorrect
use or installation of this product. Please note that Caple reserve the right
to invalidate the guarantee supplied with this product following incorrect
installation or misuse of the appliance. Under no circumstances should any
external covers be removed for servicing or maintenance except by suitably
qualified personnel.
SAFETY INSTRUCTIONS
-
Never let children operate the machine.
-
The cooker hood is for home use only, not suitable for barbecuing, restaurants or other commercial purposes.
-
The cooker hood and its filter should be cleaned regularly in order to keep in good working condition.
-
Clean the cooker hood according to the instruction manual to reduce the risk of fire.
-
When using a gas hob, do not leave naked flames under the extractor.
-
Before connecting this appliance check that the power supply cord is not damaged.
-
If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the sealed or balanced flue type. If other types of flue or appliances are fitted ensure that there is an adequate supply of air to the room.
-
The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels.
-
Regulations concerning the discharge of air have to be conformed to.
-
Do not flambé under the cooker hood.
-
Never leave frying pans unattended during use as over-heated fats and oils may catch fire.
-
To ensure the best performance, we recommend switching on the extractor 15 minutes before cooking and leave it running 15 minutes after. This will ensure that the air in the kitchen is being circulated before cooking commences and the air is being cleaned after cooking has finished.
-
The performance of your extractor will vary depending on a number of factors. These include type of extraction, room volume, length of ducting, ventilation available and the cleanliness of the filters.
-
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. -
Children should be supervised to ensure that they do not play with the appliance.
-
Cleaning and user maintenance must not be made by children without supervision.
-
Never immerse the appliance in water.
-
This appliance is intended to be used in household and similar applications such as:
- Staff kitchen areas in shops, offices and other working environments.
- Farm Houses.
- By clients in hotels, motels and other residential type environments.
- Bed and breakfast type environments.
-
To avoid all risk, if the power cable is damaged, it must only be replaced by a Caple appointed engineer.
-
Appliances can be used by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
-
Children must not play with this appliance.
-
When not in use and before cleaning, always isolate the appliance from the electrical supply.
ELECTRICAL SHOCK HAZARD
- Only plug this unit into a properly earthed outlet. If in doubt seek advice from a suitably qualified engineer.
- Failure to follow these instructions can result in death, fire, or electrical shock.
- This appliance must be connected to the mains by a competent person. We recommend that the appliance is connected by a qualified electrician who is a member of the N.I.C.E.I.C who will comply with the I.E.E and local regulations. Electrical information can be found on the rating plate.
ENVIRONMENTAL PROTECTION
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your Local Authority or
retailer for recycling advice. This appliance is marked according to the
European directive on Waste Electrical and Electronic Equipment (WEEE).
By ensuring this product is disposed of correctly, you will help prevent
potential negative consequences for the environment and human health, which
could otherwise be caused by inappropriate waste handling of this product. The
symbol on the product indicates that this product may not be treated as
household waste. Instead it shall be handed over to the applicable collection
point for the recycling of electrical and electronic equipment. Disposal must
be carried out in accordance with local environmental regulations for waste
disposal.
For more detailed information about treatment, recovery and recycling of this
product, please contact your local council, your household waste disposal
service or the retailer where you purchased the product
WARRANTY
Your new appliance is covered by warranty. The warranty card is enclosed – if
it is missing, you must provide the following information to your retailer in
order to receive a replacement: date of purchase, model and serial number.
Registration can also be completed online by visiting
www.caple.co.uk.
Ensure you keep your warranty card safe, you may need to show it to Caple
Service together with proof of purchase. If you fail to show your warranty
card you will incur all repair charges.
Spare parts are only available from Caple Service and spare parts authorized
centres.
CE DECLARATIONS OF CONFORMITY
This appliance has been manufactured to the strictest standards and complies
with all applicable legislation, Low Voltage Directive (LVD) and
Electromagnetic Compatibility (EMC).
UKCA DECLARATIONS OF CONFORMITY
This appliance has been manufactured to the strictest standards and complies
with all applicable legislation.
TECHNICAL FICHE
This appliance conforms to all current and applicable energy regulations. To
view the Technical Fiche that supports the energy labelling data, please visit
the product page on our
website www.caple.co.uk
INSTALLATION
PREPARE FOR THE INSTALLATION:
If you have an outlet to the outside, your cooker hood can be connected as per the below picture by means of an extraction duct with an interior diameter of 150mm.
Before installation, turn the unit off and unplug it from the outlet.
The cooker hood should be placed at a minimum distance of 65~76cm above the
hob. It is the manufacturer of the hob who determines the clearance required
and the clearance quoted by the hob manufacturer must be followed. In the
absence of any instructions supplied with a gas hob the minimum distance
between the hob and the hood must be at least 760mm.
The width of the extractor hood must correspond with at least the width of the
hob fitted below.
When installed above a gas hob or range cooker, do not use all the gas burners
simultaneously for prolonged periods of time at the maximum setting (max.
15mins). There can be a risk of burns if the housing or extractor surfaces
become hot, and there is also a risk that the extractor can become damaged due
to excessive heat. If 3 or more burners are used simultaneously.
Never operate the gas hob without pans situated on the burners as the excess
heat can damage the extractor.
INSTALLATION – DUCTED
WARNING:
- Observe the warning concerning the operation of the appliance when air is discharged from the room.
- When the cooker hood and appliance supplied with energy other than electricity are simultaneously in operation, the negative pressure in the room must not exceed 4 Pa (4×10-5 Bar).
- Drill 3 x 8mm holes to accommodate the bracket. Screw and tighten the bracket onto the wall with the screws and screw plugs provided.
Level up the cooker hood and hang onto the wall bracket hook.
After hanging the hood on the bracket, remove the grease filters, mark 2 holes inside the hood for safety screws. After marking, remove the hood, drill two holes and insert 2 wall plugs and finally fix the safety screws with 2 screws (ST4x30mm).
Fix the one-way-valve to the air outlet of the cooker hood. Then, attach the exhaust pipe onto the one-way-valve as shown below.
CHIMNEY INSTALLATION
Place the upper chimney into lower chimney, use 2 pcs ST4x8mm screws to attach lower and upper chimney together.
Before attaching the bracket to the chimney, decide the location of lower
chimney bracket fixing holes for fixing the lower chimney bracket in the later
steps.
NOTE: Do not fasten screws too much, make sure upper chimney can be
telescopically adjusted after assembled.
Drill 2×8mm holes to accommodate the plate II. Screw and tighten the plate II onto the wall with two screws and wall plugs provided. Slide up the upper chimney and fix the upper chimney with plate II with 2 screws ST4x8mm.
Fix the lower chimney with the hood with 2 screws ST4x8mm.
INSTALLATION – RECIRCULATION MODE
If you do not have an outlet to the outside, the exhaust pipe is not required
(as shown in the section “Installation – ducted”), and charcoal filters must be
installed.
INSTALLING THE CHARCOAL FILTER (CAP60CF)
An activated charcoal filter can be used to trap odours. In order to install
the charcoal filter, the grease filter should be detached first. Press the
release button and pull it downward as shown below.
Fit the activated charcoal filter onto the side of the motor and turn it in a clockwise direction to lock into place. Repeat the same on the other side.
Scan the QR Code to access the ‘How To’ video.
NOTE:
Make sure the filter is securely locked. Otherwise, it may loosen and be
dangerous.
When using a charcoal filter, the extraction power may be slightly reduced.
We recommend replacing these filters every 6 months. Replacement filters
(CAP60CF) can be purchased directly from www.caple.co.uk.
OPERATION
-
OFF BUTTON
Switches the extraction fan off. -
LOW SPEED BUTTON
Is suitable for simmering and cooking which does not produce much odour. -
MEDIUM SPEED BUTTON
Airflow speed is ideal for extracting with standard cooking. -
HIGH SPEED BUTTON
When a high amount of smoke or odour is produced, press the high speed button for the most effective extraction. -
LIGHT BUTTON
Switches the light on and off.
CARE AND MAINTENANCE
IMPORTANT:
Before cleaning or maintenance please switch off the electricity supply and remove the plug from the wall.
REGULAR CLEANING
Use a soft damp cloth with lukewarm mildly soapy water or household cleaning detergent. Never use metal pads, chemicals, abrasive material, abrasive cleaning creams or stiff brushes to clean the appliance.
CLEANING THE GREASE FILTER
Clean the filter every month to help minimise the risk of fire. The filter collects grease, smoke and dust, therefore the filter is directly affecting the efficiency of the cooker hood. If not cleaned, the grease residue (which is potentially flammable) will saturate the filter. It can be easily cleaned with warm water and washing up liquid, alternatively the filters can be cleaned in your dishwasher. Please ensure no other items are washed with the filters, they must be washed separately to prevent food becoming trapped in the gauze. Cleaning the grease filters in the dishwasher may lead to discolouration, this is normal and is a not a fault with the product.
REPLACING YOUR CHARCOAL FILTER
This only applies if you are using the hood in recirculation mode (not vented
to the outside). The charcoal filter traps your cooking odours and they need to
be replaced, this can vary depending on how frequently the cooker hood is
used. We recommend replacing them at least every 6 months.
This extractor uses CAP60CF charcoal filters. Filters can be purchased directly
from
www.caple.co.uk.
REPLACING THE BULB
NOTE:
The lights must be replaced by a qualified person.
- Switch off and unplug the extractor
- Remove the aluminium grease filter
- Remove the LED light by squeezing the metal clips.
- Remove the clip cover by removing the lid (see image a.)
- Unclip the light fixing (b.) and remove.
- Replace the light with the same rated LED fitting by following these instructions in reverse.
LIGHT SOURCE ENERGY CLASS
This product contains a light source of energy efficiency class G.
TROUBLESHOOTING
FAU LT | CAUSE | SOLUTION |
---|
The lights on, but the fan does not work
| The fan blade is jammed.|
Switch off the unit and contact Caple Service. To be repaired by qualified service personnel only.
The motor is damaged.
The lights and fan do not work
| A blown fuse.| Replace the fuse.
The power cord is loose.
|
Plug in to the power supply again.
Serious vibration of the unit
|
The fan blade is damaged.
| Switch off the unit and contact Caple Service. To be repaired by qualified
service personnel only.
The fan motor is not fixed tightly.| Switch off the unit and contact Caple
Service. To be repaired by qualified service personnel only.
The unit is not hung correctly on the bracket.| Take down the unit and check
whether the bracket is in the correct location.
The extraction performance is not good
|
The filter requires cleaning.
| Clean the grease filter as directed in the ‘Care and maintenance’ section. Replace the charcoal filter (if in recirculation mode).
If the above table has not solved the problem please contact Caple Service by phone on 0117 938 7420 or by email service@caple.co.uk
PRODUCT DIMENSIONS
CCH101
CCH901BK
CCH901SS
CCH701
CCH601BK
CCH601SS
Caple Service
Fourth Way
Avonmouth
Bristol
BS11 8DW
T: 0117 938 1900
E: service@caple.co.uk
www.caple.co.uk
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>