SEALEVEL SeaLINK+485 USB Serial Interface Adapter User Manual
- June 5, 2024
- SEALEVEL
Table of Contents
- SEALEVEL SeaLINK+485 USB Serial Interface Adapter
- Introduction
- Before You Get Started
- Installation & Configuration
- Linux Installation
- Hardware Installation
- Configuration
- Switch Examples
- Technical Description
- Specifications
- Appendix A – Troubleshooting
- Appendix B – How To Get Assistance
- Appendix C – Electrical Interface
- Appendix D – Asynchronous Communications
- Appendix E – Compliance Notices
- Warranty
- Trademarks
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SEALEVEL SeaLINK+485 USB Serial Interface Adapter
Introduction
Overview
The Sealevel Systems SeaLINK+485 equips the PC with 1 USB to RS-530/422/485
Asynchronous serial port providing a versatile interface for common
RS-530/422/485 needs. The advantage of this product over more traditional
approaches is that it doesn’t require opening the computer case, nor does it
require resources such as I/O ports or IRQ’s. It does require a system that
supports USB both in terms of hardware and operating system.
Before You Get Started
What’s Included
The SeaLINK+485 is shipped with the following items. If any of these items is
missing or damaged, contact the supplier.
Advisory Conventions
- Warning: The highest level of importance used to stress a condition where damage could result to the product, or the user could suffer serious injury.
- Important: The middle level of importance used to highlight information that might not seem obvious or a situation that could cause the product to fail.
- Note: The lowest level of importance used to provide background information, additional tips, or other non-critical facts that will not affect the use of the product.
Installation & Configuration
Software Installation
Windows Installation
Do not install the Adapter in the machine until the software has been fully
installed.
Only users running Windows 7 or newer should utilize these instructions for
accessing and installing the appropriate driver via Sealevel’s website. If you
are utilizing an operating system prior to Windows 7, please contact Sealevel
by calling 864.843.4343 or emailing
support@sealevel.com to receive access to the
proper driver download and installation instructions.
- Begin by locating, selecting, and installing the correct software from the Sealevel software driver database.
- Type in or select the part number (#2102) for the adapter from the listing.
- Select “Download Now” for SeaCOM for Windows.
- The setup files will automatically detect the operating environment and install the proper components. Follow the information presented on the screens that follow.
- A screen may appear with text similar to: “The publisher cannot be determined due to the problems below: Authenticode signature not found.” Please click the ‘Yes’ button and proceed with the installation. This declaration simply means that the operating system is not aware of the driver being loaded. It will not cause any harm to your system.
- During setup, the user may specify installation directories and other preferred configurations. This program also adds entries to the system registry that are necessary for specifying the operating parameters for each driver. An uninstall option is also included to remove all registry/INI file entries from the system.
- The software is now installed, and you can proceed with the hardware installation.
To confirm that the SeaCOM driver has been successfully installed, click on
the ‘Start’ button, and then select ‘All Programs’. You should see the
‘SeaCOM’ program folder listed.
You are now ready to proceed with connecting the 2102 to your system. Refer to
the Hardware Installation section for details.
Note: Windows NT is not USB aware and thus cannot support this device.
Linux Installation
Note: You MUST have “root” privileges to install the software and
drivers.
Warning: The syntax is case sensitive.
SeaCOM for Linux can be downloaded here: https://www.sealevel.com/support
/software-seacom-linux/. It includes the README and the Serial-HOWTO help
files (located at seacom/dox/howto). This series of files both explains
typical Linux serial implementations and informs the user about Linux syntax
and preferred practices.
Note: User can use a program such as 7-Zip to extract the tar.gz file.
In addition, the software selectable interface settings can be accessed by
referencing seacom/utilities/2102mode.
For additional software support, including QNX, please call Sealevel Systems’
Technical Support, 864-843-4343. Our
technical support is free and available from 8:00 AM – 5:00 PM Eastern Time,
Monday through Friday. For email support contact:
support@sealevel.com.
Hardware Installation
The screen captures below are taken from a Windows 98 installation. Your
particular operating system may differ slightly from what is shown based on
your version of windows.
The SeaLINK+485: can be connected to any Upstream Type “A” port either at the
PC host or an Upstream Hub. The SeaLINK+485 is hot-pluggable, meaning there is
no need to power down your computer prior to installation. The SeaLINK+485:
requires no user hardware configuration since there are no jumpers present on
the card.
- Connect SeaLINK+485 to an Upstream Host or Hub.
Since you have already installed the software by running “Setup”, simply click
“Next” to proceed. The drivers that were installed during setup will
automatically be used to configure the adapter for use.
Windows has now located a driver and installed the software. After the driver
has been located click “Finish”. You should see one more “New Hardware Found”,
indicating the actual port being created. If you view your systems Device
Manager at this point, you should have a new “COM” port in the Port (COM &
LPT) Device Class. It should look similar to the screen shot on the following
page.
You can access your new COM: port by using the assigned COM: identifier shown above. In this case, it is COM5: but this assignment will vary from system to system. At this point, the hardware is recognized. To verify operation, use Sealevel Systems supplied WinSSD diagnostic utility. WinSSD can be found in the Start, Programs group.
Configuration
Electrical Interface Selection
The port on the SeaLINK+485 has the ability to be used as RS-530/422/485,
RS-422 or 2 wire RS-485. This is selectable via the DIP-switch SW1. The chart
below describes each of the switch position’s function. Please refer to the
following page for switch setting examples. Switch SW1 ON enables, adds, and
connects. SW1 position OFF disables, removes, and disconnects.
SW1 | Function |
---|---|
1 | RS-485 Two Wire Auto Enable/Disable |
2 | Echo Enable/Disable |
3 | Adds or removes the 120-ohm termination |
4
| Adds or removes the 1K ohm pull-up resistor in the RS-422/RS-485 receiver circuit (Receive data only)
5
| Adds or removes the 1K ohm pull-down resistor in the RS-422/RS-485 receiver
circuit (Receive data only)
6| Connects the TX+ to RX+ for RS-485 two wire operation
7| Connects the TX- to RX- for RS-485 two wire operation
8| Not Used
Switch Examples
Please use the following examples to configure your adapter.
Technical Description
The SeaLINK+485: utilizes a USB UART. This chip features programmable baud rate, data format, 128-byte Dual Port TX Buffer, and 384-byte Dual Port RX Buffer. The RS-530/422/485 transceiver supports data rates up to 921.6K baud.
Features
- Hot-Pluggable device that doesn’t require opening the case
- No system resources are required (i.e., I/O ports or IRQ’s)
- LED status indicators for “USB Enabled”, “TD”, and “RD”
Connector Pin Assignments (DB25 Male)
The SeaLINK+485 complies with the EIA-530 pin out with the following signals supported
Signal | Name | Pin # | Mode | |
---|---|---|---|---|
GND | Ground | 7 | ||
RDB | RX+ | Receive Positive | 16 | Input |
RDA | RX- | Receive Negative | 3 | Input |
CTSB | CTS+ | Clear To Send Positive | 13 | Input |
CTSA | CTS- | Clear To Send Negative | 5 | Input |
DSRB | DSR+ | Data Set Ready Positive | 22 | Input |
DSRA | DSR- | Data Set Ready Negative | 6 | Input |
DCDB | DCD+ | Data Carrier Detect Positive | 10 | Input |
DCDA | DCD- | Data Carrier Detect Negative | 8 | Input |
TDB | TX+ | Transmit Positive | 14 | Output |
TDA | TX- | Transmit Negative | 2 | Output |
RTSB | RTS+ | Request To Send Positive | 19 | Output |
RTSA | RTS- | Request To Send Negative | 4 | Output |
DTRB | DTR+ | Data Terminal. Ready Positive | 23 | Output |
DTRA | DTR- | Data Terminal Ready Negative | 20 | Output |
Specifications
Environmental Specifications
Specification | Operating | Storage |
---|---|---|
Temperature Range | 0º to 50º C (32º to 122º F) | -20º to 70º C (-4º |
to 158º F)
Humidity Range| 10 to 90% R.H. Non-Condensing| 10 to 90% R.H. Non-
Condensing
Manufacturing
All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and
are 100% electrically tested. These printed circuit boards are solder mask
over bare copper or solder mask over tin nickel.
Power Consumption
Supply line | +5 VDC |
---|---|
Rating | 50 mA |
Mean Time Between Failures (MTBF)
Greater than 150,000 hours. (Calculated)
Physical Dimensions
Package Length | 3.8 inches (9.66 cm) |
---|---|
Package Width | 2.3 inches (5.84 cm) |
Package Height | 1.0 inches (2.54 cm) |
Appendix A – Troubleshooting
The adapter should provide years of trouble-free service. However, in the event that device appears to not be functioning incorrectly, the following tips can eliminate most common problems without the need to call Technical Support.
- If your adapter isn’t working, first check to make sure that USB support is enabled in the System BIOS and it is functioning properly in the operating system. This can be done by using either the Windows 98/ME or Windows 2000 Device Manager.
- Ensure that the Sealevel Systems software has been installed on the machine so that the necessary files are in place to complete the installation.
- When the SeaLINK+485 is configured properly, the USB Enabled LED (EN) will be lit. This should allow you to use Sealevel’s WinSSD utility and the supplied loopback plug to check communications. The supplied loopback plug connects TD to RD. If you decide to test the Modem Control Signals, a full pin loopback plug will be required. Details on loopback plugs are included on WinSSD. Contact Sealevel Systems if you need further assistance.
- When testing the SeaLINK+485 in loopback mode, you should see both the TD and RD LED”s flashing as well as seeing echoed data on the screen. The loopback test first transmits a HEX pattern, 55AA, and then an ASCII string of data. If this test passes, then the SeaLINK+485 is ready for use in your application.
- Please note that if the card is configured for 2 wire RS-485 with no echo a loopback test is not possible. The receiver in this case will be turned off and the test will fail. If you plan on using this device in two wire mode test the adapter in RS-422 mode first. Then configure the adapter for your application.
If these steps do not solve your problem, please call Sealevel Systems’ Technical Support, 864-843-4343. Our technical support is free and available from 8:00 A.M. – 5:00 P.M. Eastern Time, Monday through Friday. For email support contact support@sealevel.com.
Appendix B – How To Get Assistance
Please refer to: Appendix A — Troubleshooting Guide prior to calling Technical Support.
- Begin by reading through the Troubleshooting Guide in Appendix A. If assistance is still needed, please see below.
- When calling for technical assistance, please have your user manual and current adapter settings. If possible, please have the adapter installed in a computer ready to run diagnostics.
- Sealevel Systems provides an FAQ section on its website. Please refer to this to answer many common questions. This section can be found at http://www.sealevel.com/faq.asp.
- Sealevel Systems maintains a web page on the Internet. Our home page address is www.sealevel.com. The latest software updates, and newest manuals are available via our website.
- Technical support is available Monday to Friday from 8:00 AM to 5:00 PM Eastern Time. Technical support can be reached at 864-843-4343.
RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE WILL BE ACCEPTED. AUTHORIZATION CAN BE OBTAINED BY CALLING SEALEVEL SYSTEMS AND REQUESTING A RETURN MERCHANDISE AUTHORIZATION (RMA) NUMBER.
Appendix C – Electrical Interface
RS-530
RS-530 (a.k.a. EIA-530) compatibility means that RS-422 signal levels are met,
and the pin-out for the DB-25 connector is specified. The EIA (Electronic
Industry Association) created the RS-530 specification to detail the pin-out
and define a full set of modem control signals that can be used for regulating
flow control and line status. The RS-530 specification defines two types of
interface circuits, Data Terminal Equipment (DTE) and Data Circuit-Terminating
Equipment (DCE). The Sealevel Systems adapter is a DTE interface.
RS-422
The RS-422 specification defines the electrical characteristics of balanced
voltage digital interface circuits. RS-422 is a differential interface that
defines voltage levels and driver/receiver electrical specifications. On a
differential interface, logic levels are defined by the difference in voltage
between a pair of outputs or inputs. In contrast, a single ended interface,
for example RS-232, defines the logic levels as the difference in voltage
between a single signal and a common ground connection. Differential
interfaces are typically more immune to noise or voltage spikes that may occur
on the communication lines. Differential interfaces also have greater drive
capabilities that allow for longer cable lengths. RS-422 is rated up to 10
Megabits per second and can have cabling 4000 feet long. RS-422 also defines
driver and receiver electrical characteristics that will allow 1 driver and up
to 32 receivers on the line at once. RS-422 signal levels range from 0 to +5
volts. RS-422 does not define a physical connector.
RS-485
RS-485 is backwardly compatible with RS-422; however, it is optimized for
party line or multi-drop applications. The output of the RS-422/485 driver is
capable of being Active (enabled) or Tri-State (disabled). This capability
allows multiple ports to be connected in a multi-drop bus and selectively
polled. RS-485 allows cable lengths up to 4000 feet and data rates up to 10
Megabits per second. The signal levels for RS-485 are the same as those
defined by RS-422. RS-485 has electrical characteristics that allow for 32
drivers and 32 receivers to be connected to one line. This interface is ideal
for multi-drop or network environments. RS-485 tri-state driver (not dual-
state) will allow the electrical presence of the driver to be removed from the
line. Only one driver may be active at a time and the other driver(s) must be
tri-stated. RS-485 can be cabled in two ways, two wire and four wire mode. Two
wire mode does not allow for full duplex communication and requires that data
be transferred in only one direction at a time. For half-duplex operation, the
two transmit pins should be connected to the two receive pins (Tx+ to Rx+ and
Tx- to Rx-). Four wire mode allows full duplex data transfers. RS-485 does not
define a connector pin-out or a set of modem control signals. RS-485 does not
define a physical connector.
Appendix D – Asynchronous Communications
Serial data communications implies that individual bits of a character are
transmitted consecutively to a receiver that assembles the bits back into a
character. Data rate, error checking, handshaking, and character framing
(start/stop bits) are pre-defined and must correspond at both the transmitting
and receiving ends.
Asynchronous communications are the standard means of serial data
communication for PC compatibles and PS/2 computers. The original PC was
equipped with a communication or COM: port that was designed around an 8250
Universal Asynchronous Receiver Transmitter (UART). This device allows
asynchronous serial data to be transferred through a simple and
straightforward programming interface. A start bit, followed by a pre-defined
number of data bits (5, 6, 7, or 8) defines character boundaries for
asynchronous communications. The end of the character is defined by the
transmission of a pre-defined number of stop bits (usually 1, 1.5 or 2). An
extra bit used for error detection is often appended before the stop bits.
This special bit is called the parity bit. Parity is a simple method of determining if a data bit has been lost or corrupted during transmission. There are several methods for implementing a parity check to guard against data corruption. Common methods are called (E)ven Parity or (O)dd Parity. Sometimes parity is not used to detect errors on the data stream. This is referred to as (N)o parity. Because each bit in asynchronous communications is sent consecutively, it is easy to generalize asynchronous communications by stating that each character is wrapped (framed) by pre-defined bits to mark the beginning and end of the serial transmission of the character. The data rate and communication parameters for asynchronous communications must be the same at both the transmitting and receiving ends. The communication parameters are baud rate, parity, number of data bits per character, and stop bits (i.e., 9600, N, 8, 1).
Appendix E – Compliance Notices
Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in such case the user
will be required to correct the interference at the user’s expense.
This is a Class A Product. In a domestic environment, this product may cause
radio interference in which case the user may be required to take adequate
measures to prevent or correct the interference.
Always use cabling provided with this product if possible. If no cable is
provided or if an alternate cable is required, use high quality shielded
cabling to maintain compliance with FCC/EMC directives.
Warranty
Sealevel’s commitment to providing the best I/O solutions is reflected in the Lifetime Warranty that is standard on all Sealevel manufactured I/O products. We are able to offer this warranty due to our control of manufacturing quality and the historically high reliability of our products in the field. Sealevel products are designed and manufactured at its Liberty, South Carolina facility, allowing direct control over product development, production, burn- in and testing. Sealevel achieved ISO-9001:2015 certification in 2018.
Warranty Policy
Sealevel Systems, Inc. (hereafter “Sealevel”) warrants that the Product shall
conform to and perform in accordance with published technical specifications
and shall be free of defects in materials and workmanship for the warranty
period. In the event of failure, Sealevel will repair or replace the product
at Sealevel’s sole discretion. Failures resulting from misapplication or
misuse of the Product, failure to adhere to any specifications or
instructions, or failure resulting from neglect, abuse, accidents, or acts of
nature are not covered under this warranty.
Warranty service may be obtained by delivering the Product to Sealevel and
providing proof of purchase. Customer agrees to ensure the Product or assume
the risk of loss or damage in transit, to prepay shipping charges to Sealevel,
and to use the original shipping container or equivalent. Warranty is valid
only for original purchaser and is not transferable.
This warranty applies to Sealevel manufactured Product. Product purchased
through Sealevel but manufactured by a third party will retain the original
manufacturer’s warranty.
Non-Warranty Repair/Retest
Products returned due to damage or misuse and Products retested with no
problem found are subject to repair/retest charges. A purchase order or credit
card number and authorization must be provided in order to obtain an RMA
(Return Merchandise Authorization) number prior to returning Product.
How to obtain an RMA (Return Merchandise Authorization)
If you need to return a product for warranty or non-warranty repair, you must
first obtain an RMA number. Please contact Sealevel Systems, Inc. Technical
Support for assistance:
- Available: Monday – Friday, 8:00AM to 5:00PM EST
- Phone: 864-843-4343
- Email: support@sealevel.com
Trademarks
Sealevel Systems, Incorporated acknowledges that all trademarks referenced in this manual are the service mark, trademark, or registered trademark of the respective company.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>