immedia IM99836GT PediTurn Soft and Hard Swivel Cushion for the Floor User Manual

June 5, 2024
immedia

Instruction for use
IMM1047_IFU.Version10.2022-05-17

PediTurn Soft and Hard
by Etac

See www.etac.com 

http://q.etac.com/0038 

Illustrations

General

Thank you for choosing an Etac product.
To avoid accidents and injury when moving and handling the products, please read this manual carefully.
The person described as “the user” in this “Instruction for Use” is the person who is lying or sitting on the product. The carers are the people who manoeuvre the product.
This symbol appears alongside the text in the manual. It draws the reader’s attention to points at which there may be a risk to the health and safety **of the user or carer.
These products comply with the standards applicable for Class 1 products in the Medical Device Regulation (EU) 2017/745 on medical devices.
At Etac we strive to continually improve our products and therefore we reserve the right to make changes to products without prior warning. All measurements given on illustrations and similar material are for guidance only and Etac cannot be held liable for errors and defects.
The information given in this manual, including recommendations, combinations, and sizing, does not apply to special orders and modifications. If the customer makes adjustments, repairs or uses combinations not predetermined by Etac, the Etac CE certification and Etac warranty will not be
valid. If in doubt, please contact Etac.
Warranty:** Two-year warranty on material and manufacturing defects, provided that the product is used correctly. Expected lifetime: The device has an expected service life of 1 to 2 years under normal use. The service life of the device varies depending on usage frequency, loads, and how often, and how it is washed.
For further information on the Etac Patient handling, see www.etac.com.
In case of an adverse event occurred in relation to the device, incidents should be reported to your local dealer and the national competent authority in a timely manner. The local dealer will forward information to manufacturer.

Symbols in general

| Washing| | Disinfect / Wipe off| | Warning| | Manufacturer
---|---|---|---|---|---|---|---
| Do not bleach| | Never leave on the floor| | Production year, month and day| | CE -certification
| Tumbledry| | Risk of sliding down| | Batch no./Lot no.| | Keep dry
| Iron| | Keep out of the sun| | User mass limit =
maximum rated load| | Non sterile
| Do not dryclean| | Read the user manual| | The product can be
scrapped according to
national regulations| | Article number
| Medical device| | | | | |

Intended use
PediTurn is a slim, lightweight turnplate for floor use in connection with manual handling in the seated position, where the user must rotate but is not capable of moving his/her legs without assistance.

Intended environment
Acute care, Long-term care, Home care

Practical handling

Positioning
Place PediTurn on the floor. Position the user’s feet on the middle of PediTurn so that the user’s legs are perpendicular to the device.

Use
When manually handling a user in the seated position, the user’s legs will now follow the user, thus avoiding strain on the user’s foot, knee and hip joints (Illustration 1).
It is often beneficial to use SupportBelt, Sling or SmartMove with PediTurn.

Notice

Special features
Always check the product before use and after washing.
Never use a defective product. If the product shows signs of wear-and-tear, it must be scrapped.
Read these instructions carefully.
It is important that carers receive instruction in manual handling. Etac offers advice and training for carers. For further information, contact Etac.
Always use the correct manual handling techniques.
Encourage the user to assist where possible.
To ensure that the user feels safe and that every manual handling is smooth, always plan the manual handling in advance.
Never leave the product on the floor after use.
Always conduct a risk assessment, and ensure that the assistive product can be used for the individual user and, in combination with other devices, that it is safe for the user and carers.
Extra care is advised when using PediTurn with spastic users.
Do not take PediTurn apart – For safety reasons, if the components are taken apart, they may not be put together again. In such cases, the product must be scrapped.
If in any doubt – please contact Etac.

Material and cleaning

Material:
PediTurn Soft
Top side: Polyester, TPE
Inner surface: Nylon
Back side: Polyester, TPE
Connector disc: Polyamide.

PediTurn Hard
Top and back side: ABS/TPU
Inside: HDPE
Assembling: Brass, Steel.

The product should be checked regularly, preferably each time it is used, and especially after washing.

Check that there is no damage to seams or fabric.

Never try to repair a product yourself.
Never use a defective product.

Washing instructions:
Can be cleaned with a solvent-free cleaning agent with a pH level between 5-9, or a 70% disinfection solution.

Products and accessories

Article no. Product Description Size (mm)
IM99836GT PediTurn Soft Ø400
IM99700 PediTurn Hard Ø380

Combinations

Article no. Product Description Size (mm)
IM401 Butterfly board W320xL660
IM403 3B-Board W230xL770
IM404 E-Board L W330xL600xH5
IM405 E-Board XL W330xL750xH6
IM408 E-Board M W250xL600xH5
IM410 E-Board S W200xL450xH5
IM409 Dolphin ToiletBoard L690
IM426 SmartMove w/4 handles W210xL600
IM428 Sling – long W160xL1900
IM428K Sling – short W160xL1200
IM460PU OneManSling W75xL3000
IM8017015 SupportBelt XL 1300-1700
IM8015013 SupportBelt L 1200-1500
IM8013013 SupportBelt M 900-1300
IM8010513 SupportBelt S 650-1050
IM8010509 SupportBelt XS 650-1050
IM8009009 SupportBelt XXS 450-900

Service information

Inspection

First inspection:

  • Is the packaging intact?
  • Read the label on the packaging and check the article no. and product description
  • Check that Short Instruction is enclosed – updated User Manual/Instruction for use can be downloaded from www.etac.com or contact your Etac Customer Service or the local dealer.
  • Check the label on the product – does it include article no., product description, lot/batch no., cleaning instructions and supplier name?

Periodic Inspection:

  • Make sure that your Manual transfer system always is in a perfect condition.
  • After wash – always check materials, stitching, handles, buckles.
  • If the product shows signs of wear and tear, it must be removed from service immediately.

Visual inspection/Check the product:
Ensure that the materials, seams, stitching, handles, buckles are intact/faultless.

Mechanical load or stress/Test handles:
Draw hard in the handles in opposite directions and control the material, seams and stitching. Test buckles:
Lock the buckle and draw in opposite directions, control the buckle and the stitching.

Stability test:
Try to bend the product verify that it feels firm, stable and solid.

Test low/high friction:
Place the product on a firm surface or a bed, place your hands on the material and test the friction by pushing your hands down into the product.
Low friction – slides effortlessly High friction – no sliding/moving

Check:
Manual transfer aids with handles, straps and buckles:

Manual transfer aids with for sitting and lying transfer and with high or low friction:

| Production year, month
and day| | The product can be
scrapped in accordance with national regulations| | Read the user manual
---|---|---|---|---|---

Etac Immedia A/S
Parallelvej 3
DK-8751 Gedved
www.etac.com

UK Responsible Person.
“Etac Ltd. Unit D4A, Coombswood Business Park East,
Coombswood Way Halesowen, West Midlands B62 8BH”
E-mail: [email protected]
Website: www.etac.com/uk
Phone: +44 0121 561 222

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

immedia User Manuals

Related Manuals