Mr GARDENER GP 4600 VFI 1100 Watt Motor Power Garden Pump Instructions
- June 3, 2024
- Mr GARDENER
Table of Contents
GP 4600 VFI 1100 Watt Motor Power Garden Pump
Instructions
GP 4600 VFI 1100 Watt Motor Power Garden Pump
**** Translation of the original instructions ……..Pump seriesPlease read the instructions carefully before starting the machine.
Starting-up the device
Operation
Maintenance & Cleaning
Transport & Storage
Technical Data
Garden pump | GP 4600 VFI |
---|---|
Art. No | 5112 |
Rated voltage | 230 V |
Frequency | 50 Hz |
Motor power P1 | 1100 W |
Insulation class | F |
Degree of protection | IP X4 |
Qmax Max. delivered quantity | 4.600 l/h |
Human min. Head height | 2 m |
Max Max. head of delivery | 46 m |
Max. suction head | 8 m |
Max. Water temperature | 35 °C |
Service connection | IG 1 “ |
Dry run protection | Nein |
Net/gross weight | 11 / 12,5 kg |
Dimensions L x W x H | 505 x 245 x 335 cm |
The domestic water supply unit | HWW 4600 TL |
--- | --- |
Art. No | 5114 |
Rated voltage | 230 V |
Frequency | 50 Hz |
Motor power P1 | 1100 W |
Insulation class | F |
Degree of protection | IP X4 |
Qmax Max. delivered quantity | 4.600 l/h |
Human min. Head height | 2 m |
Max Max. head of delivery | 46 m |
Max. suction head | 8 m |
Max. Water temperature | 35 °C |
Service connection | IG 1 “ |
Tank capacity | 24 l |
Dry run protection | Ja |
Net/gross weight | 18,5 kg / 18,9 kg |
Dimensions L x W x H | 550 x 350 x 690 cm |
Read and understand the operating instructions before using the appliance.
Abide by all the safety measures stated in the service manual. Act responsibly
toward third parties.
In case of any doubts about connection and operation refer please to our
customer center|
Specified Conditions of Use
The pump is designed for pumping clean water only to supply the home with
water and to use it at home, in the garden, courtyard, and in fields.
Respecting technical data and safety precautions.
Do not use this product in any other way than stated for normal use. Not
observing general regulations in force and instructions from this manual does
not make the manufacturer liable for damages.
The pump is not suitable for long-term operation (e.g. as a circulating
pump in ponds or for brooks). If this type of operation is carried out, the
service life will be reduced accordingly.
Do not leave the pump unattended while in operation in order to prevent
subsequent damages caused by eventual malfunctions. Make sure to disconnect
the device from the grid if you do not plan on using it.
Do not use the pump for drinking water!
The pump must not be connected to the existing water-supply network as a
pressure-boosting device.
**Never use the pump as a pool circulation pump.
Safety Warnings
WARNING! Electric shock! There is a risk of an injury caused by electric
shock!
This appliance is not intended for use by persons (including children) with
limited physical, sensory or mental capabilities or insufficient experience
and/or knowledge unless they are supervised by a person who is responsible for
their safety or has been instructed by them in the safe use of the appliance.
**Children should be supervised in order to ensure that they do not play
with the tool. Always keep children and unauthorized persons out of reach of
the appliance. Operation is only allowed with a safety switch against stray
current (RCD max. stray current of 30mA).
Before putting it into operation, a qualified electrician must check whether
the electric safety measures required are in place. Any national regulations
in this regard must be complied with.
Electric connection to a socket.
Do not expose tools to rain. Do not use tools in damp or wet locations.
It is necessary to make sure the connecting socket was not near water and
humidity and that the plug was protected against humidity.
Avoid installing the appliance in wet shafts (risk of short circuit, corrosion
effects)!
Check the voltage. Technical data given on the type label must correspond with
the electric network voltage.
Only use splash-proof extension cables approved for outdoor purposes.
Do not grab the feeder cable, plunge the pump, lift or carry it while it is
connected to the grid!
Check the cable and/or socket for damages before the appliance putting into
operation.
To avoid danger, a damaged mains supply pipe must be replaced by the
manufacturer. Do not under any circumstances attempt any repair yourself.
Protect the feeder cable from excessive temperatures, oil, and sharp edges.
If the pump is in operation, neither people nor animals can be present or
plunged in the pumped liquid (e.g. pools, cellars, etc.).
The pump must not in any case run without fillings Do not leave the pump
unattended while in operation in order to prevent subsequent damages caused by
eventual malfunctions. Make sure to disconnect the device from the grid if you
do not plan on using it.
The temperature of the drained liquid must not exceed +35 °C.
When using the pump for domestic water supply, always observe the local
regulations of water management authorities and wastewater drainage.
If the pump is used in ponds, wells, etc., and appropriate pumping stations,
standards valid for pumps in the given country must unconditionally be
observed.
Do not use the pump at outside temperatures over 40 °C or under 0 °C
In cold weather, the pumping body motor should not be wrapped in a blanket or
another piece of textile with the intent to prevent the water from freezing.
The user is responsible to third parties if a pump (dumping stations, etc.) is
used.
Water escapes between the motor and pump, and mechanical seal leaks (approx.
35 drops of water per day is considered insignificant, this leakage is
functional with a mechanical seal).
Requirements for operating staff
The operating staff must carefully read the Operating Instructions before
using the appliance.
Qualification: Apart from the detailed instructions by a professional, no
special qualification is necessary for appliance using.
Minimum age: Persons over 16 years of age can only work on the appliance.
An exception includes youngsters trained in order to reach knowledge under the
supervision of the trainer during occupational education.
Training:
Using the appliance only requires corresponding training by a professional or
the Operating Instructions. No special training is necessary.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified
medical attendance as quickly as possible. Protect the injured person from
further harm and calm them down. For the sake of an eventual accident, in
accordance with DIN 13164, a workplace has to be fitted with a first-aid kit.
It is essential to replace any used material in the first-aid kit immediately
after it has been used. If you seek help, state the following pieces of
information
- Accident site
- Accident type
- Number of injured persons
- Injury type(s)
Maintenance
Before any adjustment, cleaning, and maintenance work, switch off the device
and disconnect it from the power supply. Prior to every use, visually check
the machine to rule out any defects, in particular on the power cable and the
plug. The appliance must not be used if damaged or if safety equipment is
defective. Replace any worn-out and damaged parts.
Repairs and works specified in these Instructions may only be performed by
qualified authorized staff. Use only original accessories and original spare
parts.
Caution! Depending on the design, water that is left standing for a longer
period of time may cause corrosion in the pump housing! (Brown coloration)
For winter storage, ensure that there is no water in the device. Otherwise,
frost exposure may cause irreparable damage to the device. The pump must be
stored in a completely empty and frost-proof state. You can reduce the chance
of the mechanical seals sticking by flushing out the pump with suitable oil
(e.g. vegetable oil). Only a regularly maintained and treated appliance can
serve as a satisfactory aid. Insufficient maintenance and care can lead to
unforeseen accidents and injuries.
Guarantee
The warranty period of 12 months applies to commercial use and 24 months
applies to private use and commences on the day of purchase of the device.
The guarantee solely covers inadequacies caused by material defects or
manufacturing defects.
An original payment voucher with the date of the sale needs to be submitted
for any claim in the guarantee period.
The guarantee does not cover any unauthorized use such as appliance
overloading, use of violence, or damage as a result of any unauthorized
interference or caused by foreign items. Failing to follow the operating and
assembly instructions and common wear are also not included in the guarantee.
Just in Time cannot be held responsible for damages incurred in a consequence
of unqualified installation or unskilled handling of the pump.
The device has to be checked on a regular basis to ensure perfect functioning.
Let us refer to the fact we do not assume any responsibility – according to
standards in force – for damage eventually caused by our appliances in the
below-mentioned cases:
Unprofessional repairs executed by unauthorized service centers;
Use in conflict with the designed purpose, or failure to observe the use as
designed;
Pump overload with a continuous run; Damage as a result of icing or any other
fault caused by climatic influences;
Identical regulations apply for accessory parts.
To prevent damage (such as flooded rooms, etc.) as a result of faulty pump
operation (failure or fault) the owner (user) is obliged to take reasonable
safety measures (alarm assembly, spare pump, etc.).
Service
Do you have any technical questions? Any claim? Do you need any spare parts or
operating instructions? We will quickly help you without needles bureaucracy
at our web pages at www.guede.com in the Servicing
part. Please help us be able to help you. In order to identify your device in
case of claim we need the serial No., product No. and year of production. All
this data can be found on the type label.
Serial No.:………………………………
Art. No:………………………………..
Year of production:……………………
SYMBOLS
| Read the operating instructions to reduce the risk of injury.
---|---
| The machine to be always unplugged before any adjustment and servicing work
on it.
| Insert the mains plug
| Staying in the transportation medium prohibited
| Warning against dangerous voltage
| Warning about automatic start-up
| Any damaged or disposed of electric or electronic devices must be delivered
to appropriate collection centers.
| CE marking
| TÜV / GS conformity mark
Inspection and maintenance plan
Time interval| Description|
Any other details
---|---|---
As needed| Clean the check valve and the prefilter.| Check the check valve
function.
As required| Check the pressure pipe and intake pipe for leakage and seal if
necessary| Check for any leaks
As required| Check and correct tank pressure| See page 16; Tank pressure 1,5 –
1,8 Bar
Failure removal
Failures | Causes | Removal |
---|---|---|
The engine does not start | No power supply. Blocked pump wheel | Turn the |
engine shaft with a screwdriver through the fan cover (to release
friction circles sealing that may be stuck together).
The pump does not suck| Missing, loose, or blocked check valve is not in
water.
No water in the pump shell. Too high suction head.
Air bubbles in the suction pipeline. Connections are not sealed, the pump
sucks air, and the pump is not deaerated. Prefilter clogged| Fix or clean the
check valve. Immerse the check valve in water. Fill the pump shell with water.
Check the suction head.
Check the tightening of the suction pipeline. Carefully repeat the connection
according to the chapter„Connection“!
Clean the prefilter. →17
Thermal detector switching the pump off →4| The pump is overheated and
switched off by the thermal overloading protection.
No electric power supply.
Impurity particles (e.g. pebbles) have settled down in the suction hole.| Let
the device get cool!
Check the power supply.
Disassemble and clean the suction hose, preventing the suction of foreign
substances.
Insufficient amount of water pumped| Too high suction head.| Check the suction
head.
| The strainer of the check valve is dirty| Clean the strainer., Position the
check valve lower.
| The water level quickly drops down| Check water level
Reduced switching intervals| Air pressure in the receiver is too low| Control
air pressure.→ 16
Water is coming out of the tank valve| Membrane defective| Replace/repair
(specialist workshop)
Translation of the EC-Declaration of Conformity
We, hereby declare the conception and construction of the below-mentioned
appliances correspond – at the type of construction being launched – to the
appropriate basic safety and hygienic requirements of EC Directives.
In case of any change to the appliance not discussed with us, the Declaration
expires.
Garden pump
05112 GP 4600 VPI
Appropriate EU Directives
2014/35/EU
1935/2004/EC
2011/65/EU&2015/863/EU
2016/425/EU (PPE)
2006/42/EC| 2014/30/EU
1907/2006/EC
2016/426/EU
2014/29/EU
2015/1188/EU
---|---
Annex IV
Notified Body
Name:……………..
Address:………………..
No:…………………………
Type Ex. Cert.-No.:………………..
2016/1628/EU
Emission No.:…………………
2000/14/EC_2005/88/EC
Method of compliance assessment
Annex VI
Wolpertshausen, 27.08.2020
Harmonized standards used
EN 60335-2-41:2003/A2:2010
EN 60335-1:2012/A2:2019
EN 62233:2008 AfPS GS 2019:01 PAK
EN 55014-1:2017
EN 55014-2:2015
EN IEC 61000-3-2:2019
EN 61000-3-3:2013/A1:2019
Guaranteed sound power level….. L82dB (A)
Measured sound power level…… LWA79.3 dB (A)
Managing Director
Joachim Bürkle
Just in Time GmbH, Birkichstraße 6, 74549 Wolpertshausen, Germany
Authorized to compile the technical file
The domestic water supply unit
05114 HW 4600 TL
2014/35/EU
1935/2004/EC
2011/65/EU&2015/863/EU
2016/425/EU (PPE)
2006/42/EC| 2014/30/EU
1907/2006/EC
2016/426/EU
2014/29/EU
2015/1188/EU
---|---
Annex IV
Notified Body
Name:……………..
Address:………………..
No:…………………………
Type Ex. Cert.-No.:………………..
2016/1628/EU 2018/989/EU
Emission No.:…………………
2016/1628/EC_2018/88/EC
Method of compliance assessment
Annex VI
Wolpertshausen, 27.08.2020
Harmonized standards used
EN 60335-2-41:2003/A2:2010
EN 60335-1:2012/A2:2019
EN 62233:2008 AfPS GS 2019:01 PAK
EN 55014-1:2017
EN 55014-2:2015
EN IEC 61000-3-2:2019
EN 61000-3-3:2013/A1:2019
Guaranteed sound power level….. LWA82 dB (A)
Measured sound power level…… LWA 79.3 dB (A)
Managing Director
Joachim Bürkle
Just in Time GmbH, Birkichstraße 6, 74549 Wolpertshausen, Germany
Authorized to compile the technical file
The domestic water supply unit
05114 HW 4600 TL
Joachim Bürkle
Just in Time GmbH, Birkichstraße 6, 74549 Wolpertshausen, Germany
Hersteller:
Just in Time GmbH, Birkichstraße 6, D-74549 Wolpertshausen
References
- Güde | Maschinen & Werkzeuge für den Hand- & Heimwerker
- Güde | Maschinen & Werkzeuge für den Hand- & Heimwerker
- hagebau.de – Dein online Baumarktshop
Read User Manual Online (PDF format)