RAKO RLED150CV1 150w Dimming LED Driver Instruction Manual
- June 5, 2024
- rako
Table of Contents
- General
- Mounting
- Connections
- Initial Checks
- Set-Up and Addressing
- Manual Addressing from Wall plate or Handheld
- Notes on address switches
- Notes on Addressing
- Power-Up Mode
- Manual Operation
- Multiple Control Panels
- LED functions
- Care and Maintenance
- Initial Addressing of a Rako Receiver Module
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
**RAKO RLED150CV1 150w Dimming LED Driver Instruction Manual
**
Rako RLED150CV1 Installation, Programming and Operating Instructions
General
Rako RLED150CV1 modules are dimmer units designed for use with constant voltage LED devices (usually flexible tape lighting). They are designed to accept a 12V or 24V DC supply from a power supply (normally the power supply that would power the LED device if it were not to be dimmed) and give a PWM (Pulse Width Modulation) output for smooth flicker free dimming.
RLED150CV1modules can be controlled by any Rako device that transmits wireless RAKOM messages.
Before commencing installation of a Rako module please read this instruction manual carefully. Rako Controls Ltd accepts no responsibility for damage or injury caused by incorrect installation of a Rako product.
Installation should only be carried out by a competent electrician.
Never attempt to connect a Rako module or remove the terminal cover without first isolating the circuit at the fuse/MCB board. The circuit supplying a Rako module should always be protected by either a 5A fuse or 6A MCB.
Mounting
Rako modules should be mounted in areas that are adequately ventilated, dry and outside of any enclosed metal casings that may interfere with the wireless signal.
Wherever possible the mounting bracket should be used. Modules should be mounted vertically, with the terminals at the bottom, or horizontally with the ventilation slots at the top.
Whilst Rako modules are designed to be completely maintenance free the units should be mounted in an accessible location should there be a fault or re- addressing of the unit be necessary (see ‘Set-up and Addressing’).
Connections
Connect the RLED150CV1 module according to the wiring diagram overleaf. Note the unit is designed to be fed from a 12V or 24V DC power supply. The power supply should be of an adequate rating for the connected load. For example, if dimming 4m of LED tape light with a rating of 12V and 9.6W/m the power supply needs to be rated to give at least 38.4W. If more than 5m of tape lighting is to be connected it is generally recommended to parallel the connections at the RLED150CV1 module rather than connecting the start of the second strip to the end of the first. This avoids excessive voltage drop issues.
Do not use loop In/Out connections within the module. A junction box should be used if required.
Ensure the cable clamp bar securely clamps the cables and that the terminal cover is fitted before switching the supply on.
Initial Checks
When power is initially connected to the module the unit should switch the
load ON. The load can then be manually switched using the clear button on top
of the module. The factory set address for both modules and transmitters is
House 1 Room 4 (See Fig 1 for further information). A
Rako wireless wallpanel set as address House 1 Room 4 will control and dim the
module.
Should the module not respond as above then further investigation should be
made before proceeding further.
Fig.1
Set-Up and Addressing
RLED150CV1 modules can be programmed manually or by using RASOFT programming software. For software programming refer to the appropriate programming guide supplied as a PDF with the programming interface (RA or
RTC-Bridge etc.) or download from our website: www.rakocontrols.com.
Manual Addressing from Wall plate or Handheld
Before any lighting scenes can be programmed (see the wall-panel or hand-held manual) the RLED150CV1 module needs to be addressed.
To avoid interference between neigh bouring installations choose a House address other than the factory default of House 1 and set this on the transmitters using the House address switches. Keep the House address the same throughout the project (for master functions).
Choose a Room address for each separate room or area to be controlled independently and set this on the appropriate transmitters using the Room address switches. Note: Any control panels set with the same address will act as two or multi-way controls for the same Room.
The module now needs to be sent its new House and Room address from the appropriate keypad. For rooms with multiple modules each module needs to be also assigned a separate Channel number from 1-15 within each Room.
The House and Room addresses are set using the switches on the back of a Rako transmitter (see Fig 1) and the Channel addresses are selected by putting a transmitter in programming mode and ‘stepping’ through the channel numbers (see Step 3 overleaf). This number is then ‘sent’ (along with the House and Room address) to a receiver (Step 5).
Notes on address switches
The address numbers are set using the switches on the back of a Rako transmitter. Binary coding is used and a diagrammatic explanation is given in Fig 1. It is not however necessary to understand binary just set the House switches to a different setting than the factory default and use a different combination of Room switch settings for each room or area to be controlled separately.
Notes on Addressing
A dimmer cannot be set to an address of House 0 (All switches set to off)
A dimmer will respond to, but not receive an address of Room 0 (All switches
set to off). This Room 0 address is used for ‘Master House’ control A dimmer
cannot be set to channel 0.
To program a lighting scene see Wall panel or Hand held manual.
Power-Up Mode
With the factory address setting of House 1 an RLED150CV1 will turn ON when
power is applied.
When the House address is changed the Power-Up mode becomes ‘OFF’ which is
generally preferred, for instance if there is a power cut during a holiday.
Manual Operation
The clear button can be used as a manual On/Off switch.
Multiple Control Panels
If the module is to be controlled by two wall or handheld transmitters it is only necessary to address the module to one of these transmitters. Set the other transmitters to the same House and Room address and they will transmit exactly the same message as the first transmitter and the module will respond accordingly.
LED functions
The internal LED behind the clear button will flicker when the module receives ANY Rako wireless message and is a useful diagnostic indicator. This function becomes inactive after 20 minutes to avoid nuisance light spill but can be re- activated by pressing the clear button.
If an RLED150CV1 module has already been addressed to a wall-panel the internal LED will start to pulse as soon as that transmitter (or any other transmitter with the same address) is put into programming mode. The module can still be re-addressed in the normal way, for example when changing its Channel address within the same Room.
Care and Maintenance
A Rako module contains no user serviceable parts. Should for any reason you need to contact us please contact us via our website www.rakocontrols.com or by phoning our customer help line on 01634 226666.
Initial Addressing of a Rako Receiver Module
In the following procedure both the controllers (wall panels and hand held
remotes) and the receivers have an automatic time out after approximately 3
minutes when in programming or set-up mode. This feature avoids the
possibility of either being left permanently in programming or set-up mode.
This may cause confusion if either the controller or receiver times out before
the procedure is complete. It is worth becoming familiar with the procedures
before starting the addressing procedure. If at any time it is necessary to
start again the controllers can be returned to normal mode by pressing the
‘Off button and the receivers by resetting the electrical supply.
Step 1
Set address switches on controller.
Pick a House address from 1-255 (keep same address for all panels in house) Select Room addresses from 1-255 for each room (Room 0 is master house control) .
Step 2
Put controller into programming mode by pressing and holding a scene button
and both raise and lower buttons together. After 5 seconds the LED on the
panel starts to flash. The panel is now in programming mode. Release the
buttons
TIP
Press the scene button first.
Note: A Rako panel will always enter programming mode at Channel 0. It is not possible to give a receiver an address of Channel 0 but this gives a consistent starting point.
Note. When in programming mode the buttons have functions as detailed in table 1.
Step 3
Press button 1 once to step up one channel. If this is the desired channel
i.e. Channel 1 (for the 1st receiver) then go to Step 4. If not, press button
1 again to step up to channel 2 (for the 2nd receiver), again to step to
channel 3 etc, until the desired channel number is reached (maximum = 15). It
is this channel number (along with the House and Room address) that is sent to
the receiver in Step 5. If at any point it is necessary to step down a
chanrliel, press button 2 once.
Step 4
Press the set-up button until the internal LED illuminates and keep the
button pressed with the LED on until it starts to flash. Release the button.
The module is now in set-up mode.
Note:
If a receiver is already addressed to a controller (for example a receiver is
addressed to the controller but with the wrong channel number) then the
internal LED will be flashing as soon as the panel is put into programming
mode. It will still be possible to re-address this receiver as normal.
Step 5
Press button 3 to send the ident of the channel selected in step 3. Receiver
automatically returns to normal mode (blue LED goes out) while controller
remains in programming mode (red LED keeps flashing).
Step 6
Press Off button to exit controller from programming mode.
If some receivers are already addressed to a the wall panel then they will ‘flash’ their connected lamps as their channel number is reached during the stepping procedure, this allows the user to ‘identify’ which channel numbers are already taken. To add a new receiver to an existing installation step up through the channels until a channel number is reached where no receiver flashes a load, this is then an available channel. If at any point there is uncertainty as to whether a receiver actually flashed its load then button 3 will flash the load but without stepping up or down a channel. If all of the loads flash then this indicates that the current address is Channel 0.
Note. If it is not possible to see the connected lamps flashing when
stepping through the channels it is possible to tell from the LEDs in the
receivers which will momentarily go solid when their channel address is
reached.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>