GLT MWR-17WUV50KP LED Wall Mount Installation Guide
- June 3, 2024
- GLT
Table of Contents
GLT MWR-17WUV50KP LED Wall Mount I
WARNING
- To avoid electric shock, disconnect power at source prior to installation.
- The installation should be performed by qualified electricians or lighting technicians.
- Before conducting any installation, maintenance, or removal, disable all power to the luminaries and wait until he fixture cool down.
- Do not touch the fixture while it is in service.
- If there is any problem with the fixture, DO turn off power and DO NOT attempt repair unless you are a qualified technician or the Customer service member.
- Please read the label information carefuly to get proper input voltage for this product.
- This luminaire is designed to operate in ambient temperatures ranging from-40°c to 40°c.
- This product is not available for several special environments, such as places with corrosive gas liquids or high pressure water vapor.
J-box Mounting
- Loosen two set screws and remove metal template.
- Install EVA gasket on the back of the metal template (Note the direction of the arrow).
- Pull house supply wires through hole in housing back and secure housing to junction box with two mounting screws( by others).
- Connect Black for line, White for Neutral and bare wire for Ground to complete the wiring.
- Secure the fixture on the metal template with set screws.
1/2″ Conduit Mounting
- Loosen two set screws and remove metal template.
- Install EVA gasket on the back of the metal template (Note the direction of the arrow).
- Pull house supply wires through hole in housing back and secure housing to junction box with two mounting screws( by others).
- Thread 1/2″ conduit into the 1/2″ hole.
- Connect Black for line, White for Neutral and bare wire for Ground to complete the wiring
- Secure the fixture on the metal template with set screws.
Note: To ensure waterproof seal, apply weatherproof silicone sealantaround the edge of the wall mounting box and /or junction box. This is especially important with an uneven wall surface. Silicone all plugs and unused conduit entries.
PHOTOCELL INSTALLATION
- Install photocell and wire as per diagram.
- Use photocell rated for your supply voltage.
TROUBLESHOOTING
- Check that the line voltage at the fixture is correct. Refer to wiring directions.
- ls the fixture grounded properly.
- Be sure the photocell, if used, is functioning properly.