Safety instructions
- Read the safety instructions and also this manual carefully.
- Keep the manual.
- Observe all red flags.
- Observe the manual.
- To prevent fire or electric shocks, protect the device against rain and humidity
- Pull the plug before opening the housing.
- To prevent an electric shock you should not remove the cover.
- Do not operate the device in the near of water.
- Use only a dry cloth for cleaning.
FOR SAFE AND EFFICIENT OPERATION
Be careful with heat and extreme temperature
Avoid exposing it to direct rays of the sun or near a heating appliance. Not
put it in a temperature bellow 41°F /5°C, or exceeding 95°F /35°C.
To avoid placing on un-stable location
Select a level and stable location to avoid vibration.
Do not use chemicals or volatile liquids for cleaning
Use a clean dry cloth to wipe off the dust, or a wet soft cloth for stubborn
dirt. Pull the plug before cleaning.
If out of work, contact sales agency immediately
Any troubles arose, remove the power plug soon, and contact with an engineer
for repairing, do not open the cabinet by yourself, it might result a danger
of electric shock.
Take care with the power cable
Never pull the power cable to remove the plug from the receptacle, be sure to
hold the plug. When not using the device for an extended period of time, be
sure to disconnect the plug from the receptacle.
Ventilation
It is not allowed cover fans and air in and outlets.
Safety
Do not remove the grounding. It is for your safety. If you remove the
grounding it can cause electric shocks.
Accessory
Please use only the accessory which is set by the manufacturer.
Important
Damages caused by the disregard of this user manual are not subject to
warranty. The dealer will not accept liability for any resulting defects or
problems. Make sure the electrical connection is carried out by qualified
personnel. All electrical and mechanical connections have to be carried out
according to the European safety standards.
Overview
Front view
-
LCD Display
-
Channel LED 1-6
-
DMX LED
This LED lights up if a DMX signal is present. -
Channel buttons 1-6
These buttons are used to change the intensity of corresponding channel. -
MENU
With this button you can enter the menu. -
UP/DOWN buttons
With this buttons you can scroll to the required point of menu or increase/decrease values. -
ESC Taste
Tap this button to leave menu setting or save setting parameter. In the beginning menu, this button is used to reverse the change direction of channel setting. -
Circuit Breakers (20 A per channel)
Rear view
-
Power input
AC 230 V, 50/60 Hz, 120 A max. -
Terminal
Phase (single): 20 A/channel, Total: 120 A Three phases: 20 A/channel, Total: 40 A/Phase -
DMX OUT
3pol XLR output female. -
DMX IN
3pol XLR input male. -
Analogue input
DC 0-10 V pulse signal
Wiring Diagram
Control
Apply power to this unit, firstly the LCD reads the revision of software. Then
the display shows a row of dynamic images and a row of characters, the first
row represents the intensity value, and the second row indicates the channel.
Adjust channel intensity
Tap the channel button to select the desired channel intensity, each tap will change intensity once. If you press and hold the button the channel intensity will change quickly. If you tap the ESC button the direction of channel intensity will be reserved.
Adjust whole intensity
Tap the UP/DOWN buttons to increase/decrease the channel intensity. Each tap will change intensity once. If you press and hold the button the channel intensity will change quickly.
Structure of the menu
Tap MENU to enter the menu. . There are 5 points of menu: Patching, DMX Fail, Max Level, Min Level and Curve. You can use UP/DOWN buttons to scroll through the menu. Tap ESC button to exit the menu.
Patching
-
Tap UP/DOWN button to scroll to Patching.
-
Tap MENU button to enter the submenu. You can use UP/DOWN buttons to select between Start and Independent.
Start: The DMX addresses of the individual channels, starting from the selected starting address, are sequentially. Independent: The DMX address of each channel can be independently selected, so also all channels the same DMX address can be assigned.
-
Tap UP/DOWN button to scroll to Start/Independent. Tap the MENU button to choose the accordingly menu.
-
In Start-mode, you can use the UP/DOWN buttons to select the starting address of the 6 channels.
-
In Independent-mode you can choose with the UP/DOWN buttons between All and Single. Confirm by pressing the MENU button.
-
In All-mode you can set the DMX address with the UP/DOWN buttons In All-mode all channels have the same DMX address.
-
In Single-mode tap the MENU button, to select between channel and address. In Single-mode the DMX address of each channel can be selected separately.
-
If channel is activated, tap the UP/DOWN buttons to choose between the channels 1-6. If address is activated, tap the UP/DOWN buttons to choose the DMX address 1-512.
-
Tap ESC button to save in memory and get back to step 1.
DMX Fail
-
Tap UP/DOWN button to scroll to DMX Fail.
-
Tap MENU button to enter the submenu. You can use UP/DOWN buttons to select between Last Hold, Analog and Progrm01-12.
Last Hold: The DMX signal which was received at last is hold. Analog: The analogue input (0-10 V) is activated.
Porgr:01-12: Starts built-in programs 1-12 automatically.
-
If you have select Last Hold or Analog, you can tap the ESC button to conform your settings.
-
If you have select Progr:01-12-mode the Velocity menu is activated.
-
With the UP/DOWN buttons you can select the chasing velocity between 00.005s and 30.00.
-
Tap ESC button to save in memory and get back to step 1.
Max Level
-
Tap UP/DOWN button to scroll to Max Level.
-
Tap MENU button to enter the submenu.
-
You can use UP/Down buttons to select between All and Single. Tap the MENU button to choose the accordingly menu.
-
In All mode you can tap the UP/DOWN buttons between Max Level 70-100% for all channels.
-
Tap the MENU button in Single-mode, to choose between the channel and Max Level.
-
If channel is activated, tap the UP/DOWN buttons to choose between the channels 1-6. If level is activated, tap the UP/DOWN buttons to choose the Max Levels 70-100%.
-
Tap ESC button to save in memory and get back to step 1.
Min Level
-
Tap UP/DOWN button to scroll to Min Level.
-
Tap MENU button to enter the submenu.
-
You can use UP/Down buttons to select between All and Single. Tap the MENU button to choose the accordingly menu.
-
In All mode you can tap the UP/DOWN buttons to choose between Min Level von 0-30% for all channels.
-
Tap the MENU button in Single-mode, to choose between the channel and Min Level.
-
If channel is activated, tap the UP/DOWN buttons to choose between the channels 1-6. If level is activated, tap the UP/DOWN buttons to choose the Min Levels 0-30%.
-
Tap ESC button to save in memory and get back to step 1
Curve
-
Tap UP/DOWN button to scroll to Curve.
-
Tap MENU button to enter the submenu.
-
You can use UP/Down buttons to select between All and Single. Tap the MENU button to choose the accordingly menu.
-
In All mode you can tap the UP/DOWN buttons to choose between Linear, S-Curve, Non Dim und Square for all channels.
-
Tap the MENU button in Single-mode, to choose between the channel and Linear, S-Curve, Non Dim und Square.
-
If channel is activated, tap the UP/DOWN buttons to choose between the channels 1-6. If curve is activated, tap the UP/DOWN buttons to choose the Linear, S-Curve, Non Dim und Square.
-
Tap ESC button to save in memory and get back to the main menu.
Technical Dato
Power supply
Channel Output (3 phases)| 20 A/CH; 3x 32 A
Channel Output| 20 A/CH; Total 120A
Voltage| 32 A, 400 V AC
Connections
Strom in| Terminal
Strom out| Terminal
XLR in/out| 3pol XLR
Controlling
Dimming curve| Linear
Switch| Switch/Square
Automatic| Yes
DMX512| Yes
Number of canals| 6
Dimensions (L/B/H)| 482 x 325 x 88 mm
Weight| 8 kg
IMPORTER
B&K LUMITEC 2 rue Alfred Kastler Zone Industrially 67850 Herrlisheim – France
+33 (0) 3.88.96.80.90 +33 (0) 3.88.96.48.46