JBC B·IRON 115T Nano Tweezers B·iRON Station Instruction Manual

June 5, 2024
JBC

www.jbctools.com

Nano Tweezers B·iRON Station
B·IRON 115T

This manual corresponds to the following references:

Console included:
BI115TUA 120 V – N. America, Taiwan
BI115TIA 230 V – India
BI115TA 230 V – Europe
BI115TKA 230 V – United Kingdom
BI115THA 230 V – China
BI115TJA 100 V – Japan| Console not included
:
BI115TUQA 120 V – N. America, Taiwan
BI115TIQA 230 V – India
BI115TQA 230 V – Europe
BI115TKQA 230 V – United Kingdom
BI115THQA 230 V – China
BI115TJQA 100 V – Japan
---|---

Packing List

The following items are included:

| Stand for B 115T Nano
B·iRON Tweezers ……… 1 unitRef. B210-SA
---|---
| B 115T Nano B·iRON
Tweezers …………………… 1 unit Ref. B210-A
| B·iRON Console 7”…… 1 unit
included according to purchased reference
| Cable USB ………………….. 1 unit
Ref. 0028092
| Brass Wool ………………… 1 unit Ref. CL0300
already assembled in the stand
| Manual ………………………… 1 unit
Ref. 0028298
| Power Cord ……………… 1 unit*
Ref. 0027380 120V – N. America, Taiwan
0027381 230V – India
0027382 230V – Europe| 0027378 230V – United Kingdom
0027379 230V – China
0028103 100V – Japan
---|---

Features and Connections

B·iRON Console 7”
Note: for references without console blue tooth devices like PC or mobile can be connected.

Quick Start

  1. Connection

Connect the stand to the mains (100 – 240 V).

  1. Cartridge Insertion and Charging

Insert a cartridge into the tool (1) and place it into the charger on the stand (2).
Note: Charge the tool completely (30 min) before using for the first time.

The status indicator light indicates as follows the tool status:

green working/soldering
green blinking charging
alternating red/green blinking low battery, less than 20%
red blinking: no cartridge
no color: power OFF

3. Switching on Console/Device

Turn on the console/device and open the B·iRON Application:

4. Selecting Tool

Select the tool from the detection list.

Console Work Screen

The work screen shows the graph of the current tip temperature and the power supplied to the tip by moving the graph permanently to the left.

Operation

The JBC Most Efficient Soldering System
This revolutionary technology is able to recover tip temperature extremely quickly. This allows the user to work at a lower temperature.

Work

When the tool is lifted from the stand the tip will heat up to the selected temperature.

Charging and Hibernation

When the tool is in the stand enters into Hibernation Mode and cools down to room temperature. While the tool remains on the stand, it charges.
Note: When the tool is lifted from the stand the Soldering System acts as follows:

When the tool is outside of the stand and remains inactive (no movement), the tool enters into Hibernation mode and cools down to room temperature.| To turn the tool on, put it back into the stand.| If the tool has been inactive for a longer period of time, it is turned off.

Note: If desired, the tool can be switched off/on. Tab the Tool Power button at the tablet screen (bottom right) to switch it off/on.

Grafics

The work screen shows the automatic recording of the temperature and power graphics.
The automatic recording can be paused by tapping the screen in the graphic area. The automatic recording stops also when the tool stops working.
While the automatic recording is stopped, you can get the temperature/power value at a certain point by tapping the graph on the tablet screen.

The graphic can be moved to the left and right by swiping the touch screen sideways with one finger.
The recording starts automatically as soon as the tool is removed from the stand and the graphic automatically jumps to the end of the last recording and continues with the recording.
Note: When the tool is placed on the stand and is not in use, the temperature/power recording stops. A gap can then be seen in the curve grafics.

Tip Cleaner

Select the option to suit your needs and improve the tip thermal transfer.

The antisplash membrane prevents splashing and keeps the work area clean.
Includes a temperature-resistant wiper for removing excess solder by gently tapping or wiping the cartridge tip.
If the tip is very dirty, JBC recommends first cleaning it with the wiper to remove excess solder and then with the brass wool.

Wiper

Replacing Brass Wool

  1. **Lifting

Lift and remove the antisplash membrane.
**

  1. Replacing
    Replace the brass wool with a new one. Make sure that the brass wool is on the far left and that there is space for the wiper on the right.

  2. Assembling

Assemble the antisplash membrane in vertical direction onto the stand.

  1. Pressing on

Press the antisplash membrane down. Make sure that the membrane is correctly inserted all around.
Note: The brass wool and the wiper position can be reversed by rotating the antisplash membrane 180 degrees

Quick Tip Changer

Save time and change cartridges safely without switching the station off.

Place the tweezers with the cartridge in the extractor slot and pull to remove it.| Place the tweezers on top of the new cartridge and gently push the tweezers down.| Place the tweezers with the cartridge in the slot, so that its reference ring rests in the slot, and gently press the cartridge
into the tweezers*.

*Important: Push the cartridge in as far as it will go, until the reference ring rests against the tweezers. The charging indicator light changes from red to green when the cartridge is properly inserted.

Cartridge Tip Alignment

Nano B·iRON Tweezers offers an intuitive cartrige tip alignment function. Cartridge tips can be rotationally and vertically aligned.

Rotationally Tip Alignment

Rotate the bushings slightly (1) to rotationally align the tips (2).

Vertically Tip Alignment
Rotate the wheel slightly (1) to vertically align the cartridge tips (2).

Compatible Cartridges

B 115T Nano B·iRON Tweezers works with C115 Cartridges.
Find the model that best suits your soldering needs in www.jbctools.com

The B·iRON Console offers an intuitive user interface that provides quick access to station parameters.

Parameters

Parameter|

Description

---|---
Tool ID| Allows to change the tool identifier.
PIN| Allows to change the PIN
Hibernation Delay| Set hibernation delay from 5 to 15 sec. Countdown starts when no movement is detected.
Sleep Mode /Sleep Temperature| Set sleep mode ON/OFF. The tip temperature will drop to the selected sleep temperature.
Maximum Temperature| Allows selection of the maximum temperature that can be set for the work mode
Tool Status| The tool status light indicates as follows the tool status:
– Green: working/soldering
– Green blinking: charging
– Alternating red/green blinking: low battery, less than 20%
– Red blinking: no cartridge
– No color: power OFF

B·iRON Update

  • Download the JBC update file from: https://www.jbctools.com/jbcsoftware.html
  • Connect the console/device via USB connection to the PC. – On the console/device notification bar at the top, open “USB Connection Settings” and select “MTP”.
  • On the PC copy the downloaded file to “IT706/internal share storage/JBC”.
  • Once copying is finished, disconnect the console/device from the PC.
  • On the console/device open the Application (1) and then select “update” (2) on the Application Menu.

  •  Use the update button of the version to be downloaded.

Maintenance

Before carrying out maintenance, always extract the cartridge and disconnect de B·iRON from the mains. Allow the equipment to cool down.

  • Use a damp cloth to clean the casing and the tool. Alcohol can only be used to clean the metal parts.
  • Periodically check that the metal parts of the tool and stand are clean so that the charging works properly.
  • Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation. Rusty and dirty surfaces reduce heat transfer to the solder joint.
  • Do not use liquid such as alcohol, thinner, or benzene to clean the console.
  • Repairs should only be performed by a JBC authorized technical service.

Safety

**** It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.

  • Do not use the units for any purpose other than soldering or rework. Incorrect use may cause a fire.

  • The power cord must be plugged into approved bases. When unplugging it, hold the plug, not the wire.

  • Do not work on electrically live parts.

  • The tool should be placed in the stand when not in use in order to charge the batteries.

  • The soldering tip or nozzle, the metal part of the tool, and the stand may still be hot even when the station is turned off.

  • Do not leave the appliance unattended when it is on.

  • Avoid flux coming into contact with skin or eyes to prevent irritation.

  • Be careful with the fumes produced when soldering.

  • Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm.

  • Utmost care must be taken with liquid tin waste which can cause burns.

  • This appliance can be used by children over the age of eight and also persons with reduced physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning the use of the appliance and understand the hazards involved.
    Children must not play with the appliance.

  • Maintenance must not be carried out by children unless supervised.

  • Do not expose the console to high temperatures, humidity, or dust. Avoid direct sunlight.

  • Do not drop the console as it may cause damage or malfunction.

  • Do not disconnect your device when it is in fi le transfer mode.

  • Do not use the console in places where electronic devices are restricted.

Notes
………………………………………………

Specifications

B·iRON 115T
Nano Tweezers B·iRON Station 

With Console:
Ref. BI115TUA 120 V – N. America, TaiwanRef. BI115TIA 230 V – India
Ref. BI115TA 230 V – Europe
Ref. BI115TKA 230 V – United Kingdom
Ref. BI115THA 230 V – China
Ref. BI115TJA 100 V – Japan| Without Console:
BI115TUQA 120 V – N. America, Taiwan
BI115TIQA 230 V – India
BI115TQA 230 V – Europe
BI115TKQA 230 V – United Kingdom
BI115THQA 230 V – China
BI115TJQA 100 V – Japan
---|---

Stand:

– Input:
-Power:
– Tool output:
– USB output:| 100 V – 240 V 50/60 H
15 W
12 V / 350 mA
5 V / 1000 mA
---|---

Tool:

– Output Peak Power:
– Battery:
– Charge Time:
– Temperature Range:
– Idle Temp. Stability (still air):
– Temp. Accuracy:
– Connections:
– Ambient Operating Temp:
– Tool Weight:| 5 W
Li-Ion 7.4 V / 180 mAh
40 minutes
200 – 450 °C / 390 – 840 °F
±1.5 °C / ±3 °F
±3% (Using reference cartridge)
Bluetooth Low Energy (BLE)
10 – 50 °C / 50 – 122 °F
55 g / 0.12 lb
---|---

With Console

– Total Net Weight:
– Total Package Dimensions/Weight:
(L x W x H)| 1462 g / 3.22 lb
265 x 223 x 160 mm / 2020 g
10.43 x 8.78 x 6.30 in / 4.45 lb
---|---

Without Console

– Total Net Weight:
– Total Package Dimensions/Weight:
(L x W x H)| 998 g / 2.20 lb
225 x 223 x 160 mm / 1556 g
8.86 x 8.78 x 6.30 in / 2.34 lb
---|---

Complies with CE standards ESD safe
Not grounded device. No ESD discharge feature.

Warranty
JBC’s 2-year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour. Warranty does not cover product wear or misuse. In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased. Get 1 extra year of JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase.
**** This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility.

         www.jbctools.com
0028298-080722

Documents / Resources

| JBC B·IRON 115T Nano Tweezers B·iRON Station [pdf] Instruction Manual
B IRON 115T, Nano Tweezers B iRON Station, B IRON 115T Nano Tweezers B iRON Station
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals