greencreative 34888 12W 3Ft LED T8 Tube User Guide

June 5, 2024
GREENCREATIVE

greencreative 34888 12W 3Ft LED T8 Tube

greencreative-34888-12W-3Ft-LED-T8-Tube-PRODUCT

INSTALLATION GUIDE – NOT

NOTE:

  • This product is suitable for use with existing ballasts or with directly on line voltage 120-277V power.
  • Not intended for use with emergency exit fixtures or emergency exit lights.
  • LAMPS MUST BE OPERATED WITHIN AN AMBIENT FIXTURE TEMPERATURE OF -4ºF (-20ºC) AND 95ºF (35ºC).
  • SUITABLE FOR DAMP LOCATIONS. Suitable for use in wet locations when used in an outdoor-rated fixture. Not for use where directly exposed to the weather or water.
  • Complies with Part 15 of FCC. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received including interference that may cause undesired operation.

LED TUBE DIRECT INSTALLATION GUIDE – WARNING

CAUTION:

• Suitable for use with existing ballasts,for a complete list visit www.greencreative.com.
• This lamp is not compatible with luminaires that use a remote starter.
• Suitable to replace T8 fluorescent lamps as specified on the product label.

CAUTION – RISK OF FIRE. IF THE LAMP OR LUMINAIRE EXHIBITS UNDESIRABLE OPERATION (BUZZING, FLICKERING, ETC.), IMMEDIATELY TURN OFF
POWER, REMOVE LAMP FROM LUMINAIRE AND CONTACT MANUFACTURER.
CAUTION – RISK OF FIRE. DO NOT INSTALL THIS LAMP IN A PRE-HEAT LUMINAIRE.
WARNING – RISK OF FIRE. USE ONLY IN PLACE OF FLUORESCENT LAMPS SPECIFIED ON LABEL. SEE INSTRUCTIONS.
THIS LAMP ONLY OPERATES ON ELECTRONIC BALLASTS. IF LAMP DOES NOT LIGHT WHEN THE LUMINAIRE IS ENERGIZED, REMOVE LAMP FROM
LUMINAIRE AND CONTACT LAMP MANUFACTURER OR QUALIFIED ELECTRICIAN.
The minimum lamp compartment dimensions are described below:

Model Number

| 12T8/4F/xxx/HYB

15T8/4F/xxx/HYB

---|---

Minimum Compartment Dimensions

| Length| 47-13/16″
Width| 23-13/16“
Height| 2-15/16”
Maximum Lamps in Luminaire| 4

Where xxx means 824-965 which indicates CRI and color temperature

INSTALLATION INSTRUCTIONS:

greencreative-34888-12W-3Ft-LED-T8-Tube-FIG1

LED TUBE BYPASS SINGLE ENDED WIRING INSTALLATION GUIDE – WARNING

WARNING – Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire
WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
WARNING – Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components.

  • Disconnect power at the source before installation, inspection or removal. Do not simply switch off fixture.

  • This item is rated at 120-277V. Installer must determine whether line voltage 120-277V is available at the luminaire before installation.

  • Not intended for use with emergency exit fixtures or emergency exit lights.

  • Not for use with luminaire ballast.

  • Suitable for use with non-shunted lamp holders only for single ended wiring.

  • Connect hot wire only to end cap with the L and N markings. See Diagram 2. Opposite end cap is dead, do not wire.

  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

  • For single-ended wiring, to avoid potential fire or shock hazard, do not use this retrofit kit in luminaires employing shunted bi-pin lamp holders. Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-Start ballasts can be identified by the words “Instant Start” or “I.S.” marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example, F40T12/IS. For more information, contact the LED luminaire retrofit kit manufacturer.

  • “This luminaire has been modified to operate LED lamps” shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance including
    re-lamping.

  • Risk of fire or electric shock. Do not open or modify. No user serviceable parts inside.

  • Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead installers should cut existing lamp
    holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors.

  • SUITABLE FOR “TYPE IC” OR “TYPE NON-IC” LUMINAIRES.

  • THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. greencreative-34888-12W-3Ft-LED-T8-Tube-FIG2

LED TUBE BYPASS SINGLE ENDED WIRING INSTALLATION GUIDE – INSTALLATION

STEPSgreencreative-34888-12W-3Ft-LED-T8-Tube-FIG3

  1.  Read all WARNINGS before continuing this section.
  2.  Ensure fixture is 120-277V.
  3.  Make sure POWER IS TURNED OFF AT THE SOURCE.
  4.  Remove lens if applicable, remove cover and fluorescent tubes.
  5.  Cut all wires that connect ballast (Cf. Diagram 1). Properly discard ballast or cap off wires. Cut wire away from lamp holders.
  6.  If applicable, replace lamp holders at power end with non-shunted lamp holders.
  7.  Connect Live (L) from power source into non-Shunted lamp holder “L In”.
  8.  Connect neutral (N) wire from power source into non-Shunted lamp holder “N In”.
  9.  If installing a single tube refer to Diagram 3 and go to section 13. If connecting multiple lamps, continue reading.
  10. Connect separate hot wire into “Hot Out” from primary source lamp holder and connect that wire into “Hot In” on the adjacent tube.
  11.  Connect separate neutral wire into “Neutral Out” from primary source lamp holder and connect that wire into “Neutral In” on the adjacent tube. See Diagram 4 below.
  12.  Continue this process for additional lamps.
  13.  This device is powered on one end only; the end with L and N markings (Cf. Diagram 2). Do not wire opposite end of lamp holder.
  14.  Install lamp with the L and N markings into the wired lamp holder end.
  15.  Visibly affix “Modification Sticker” and reinstall housing cover and lens if applicable.
  16.  Return power back to source and installation is now completed.

LED TUBE BYPASS DOUBLE ENDED WIRING INSTALLATION GUIDE – WARNING

WARNING – Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
WARNING – Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components.

  • Disconnect power at the source before installation, inspection or removal. Do not simply switch off fixture.
  • This item is rated at 120-277V. Installer must determine whether line voltage 120-277V is available at the luminaire before installation.
  • Not intended for use with emergency exit fixtures or emergency exit lights.
  • Not for use with luminaire ballast.
  • Do not use if product is damaged.
  • Suitable for use with non-shunted and shunted lamp holders.
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
  • “This luminaire has been modified to operate LED lamps” shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance including re-lamping.
  • Risk of fire or electric shock. Do not open or modify. No user serviceable parts inside.
  • Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors.
  • SUITABLE FOR DAMP LOCATIONS. Suitable for use in wet locations when used in an outdoor-rated fixture. Not for use where directly exposed to the weather or water.
  • SUITABLE FOR “TYPE IC” OR “TYPE NON-IC” LUMINAIRES.
  • THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION.

LED TUBE BYPASS DOUBLE ENDED WIRING INSTALLATION GUIDE – INSTALLATION

STEPS

greencreative-34888-12W-3Ft-LED-T8-Tube-FIG5 greencreative-34888-12W-3Ft-LED-T8-Tube-FIG6

  1.  Read all WARNINGS before continuing this section.
  2.  Make sure POWER IS TURNED OFF at the source to the location at which you are installing the product.
  3.  Remove lens, cover and fluorescent tubes. Cut away all wires connecting the ballast. (fig. 1)
  4.  It is not needed to change socket (if in good condition) to operate double ended lamps, regardless the type of sockets. Please make sure one side of fixture is connected to Live (L) and the other side to Neutral (N)
  5. Follow wiring diagrams for number of lamps and original ballast type (instant start, programmed start or rapid start). (fig.2-7)
  6. Visibly affix the “Modification Sticker” to the fixture and reinstall housing cover and lens if applicable.
  7. Return power back to the source and installation is complete.

www.greencreative.cominfo@greencreative.com – Tel / Fax: 866-774-5433
/ GREENCREATIVELED

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals