** For model #: 24PAR38HO8/xxxyyyyy/277V/SD
Where xxx means 824-965 which indicates CRI and color temperature and yyyy
means SP15, NF25, or FL40 which indicates beam angle
Pour les produits suivants: 24PAR38HO8/xxxyyyyy/277V/SD
LED PAR LAMP INSTALLATION GUIDE – WARNING
CAUTION – IF THE LAMP OR LUMINAIRE EXHIBITS UNDESIRABLE OPERATION
(BUZZING, FLICKERING, ETC.), IMMEDIATELY TURN OFF POWER, REMOVE THE LAMP FROM
THE LUMINAIRE AND CONTACT THE MANUFACTURER.
WARNING – Risk of fire or electric shock. LED Retrofit Kit installation
requires knowledge of luminaire electrical systems. If not qualified, do not
attempt installation. Contact a qualified electrician. Installation should be
performed only by a qualified electrician in accordance with the National
Electrical Code and relevant local code.
WARNING – Risk of fire or electric shock. Install this kit only in the
luminaires that have the construction features and dimensions shown in the
photographs and/or drawings and where the input rating of the retrofit kit
does not exceed the input rating of the luminaire.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to
the edges of sheet metal or other sharp objects.
-
Disconnect power at the source before installation, inspection, or removal. Do not simply switch off the fixture.
-
Not intended for use with emergency exit fixtures or emergency exit lights.
-
Not for use with luminaire ballast.
-
Do not use it if the product is damaged.
-
This lamp is non-dimmable. Not for use with dimmers.
-
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
-
“This luminaire has been modified to operate LED lamps” shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance including
re-lamping. -
Risk of fire or electric shock. Do not open or modify. No user-serviceable parts inside.
-
This item is rated at 120-277V. The installer must determine whether line voltage 120-277V is available at the luminaire before installation.
-
Before retrofitting, the installer must confirm the voltage of the branch circuit is 120V. If the voltage of the branch circuit exceeds 120V, the lamp cannot be installed.
-
Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead, installers should cut existing lamp
holder leads away from the lamp holder and makes new electrical connections to lamp holder lead wires by employing applicable connectors. -
SUITABLE FOR DAMP LOCATIONS. The units covered in this report are intended to retrofit a maximum of one lamp, Type IC or Type non-IC recessed luminaires without a diffuser.
Not for use where directly exposed to the weather or water. -
Complies with Part 15 of FCC. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received including interference that may cause undesired operation.
-
No external weight or mechanical force should be applied to the lamp or components.
-
THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY UL OR AUTHORITIES HAVING JURISDICTION.
LED PAR LAMP INSTALLATION GUIDE – INSTALLATION STEPS / GUIDE INSTALLATION
– ETAPES INSTALLATION
- Read all WARNINGS before continuing this section.
- Ensure the fixture is 120-277V.
- Make sure the POWER IS TURNED OFF AT THE SOURCE.
- Remove the lens if applicable, and remove the cover and lamp.
- Before rewiring, check the ballast type and refer to the relevant diagram.
- Before rewiring, please check the number of lamps per fixture and refer to the relevant diagram.
- Adjust the side dimming knob to the target dimming position. (factory default is 100% lumen output). Diagram 1.
- If the fixture is new without ballast, please refer to Cf. Diagram 3.
- If the fixture ballast type is electronic, please refer to Cf. Diagram 4.
- If the fixture ballast type is magnetic please refer to Cf. Diagram 5.
- Install the lamp into the wired lampholder.
- Visibly affix the “Modification Sticker” and reinstall the housing cover and lens if applicable.
- Return power back to source and installation is now complete.
Diagram 1-Slide switch dimming adjust
Switch position | Wattage range |
---|---|
H | 100% |
M | 70% |
L | 45% |
Diagram 2 – Minimum lamp compartment dimensions (for enclosed fixtures)
Diagram 3 – New fixture without ballast wiring
Diagram 4 – Electronic ballast fixture wiring modification
Diagram 5 – Magnetic ballast fixture wiring modification
www.greencreative.com
–info@greencreative.com
– Tel / Fax:866-774-5433
– / GREENCREATIVELED
/ GClightingLED
/ GREEN-CREATIVE
Documents / Resources
|
GREENCREATIVE 24PAR38HO8 LED PAR
Lamp
[pdf] Installation Guide
24PAR38HO8, LED PAR Lamp, 24PAR38HO8 LED PAR Lamp, PAR Lamp, Lamp
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>