GREENCREATIVE LED Par Lamp Installation Guide
- June 4, 2024
- GREENCREATIVE
Table of Contents
GREENCREATIVE LED Par Lamp
CAUTION – IF THE LAMP OR LUMINAIRE EXHIBITS UNDESIRABLE OPERATION
(BUZZING, FLICKERING, ETC.), IMMEDIATELY TURN OFF POWER, REMOVE LAMP FROM THE
LUMINAIRE AND CONTACT THE MANUFACTURER.
WARNING – Risk of fire or electric shock. LED Retrofit Kit installation
requires knowledge of luminaire electrical systems. If not qualified, do not
attempt installation. Contact a
qualified electrician. Installation should be performed only by a qualified
electrician in accordance with the National Electrical Code and relevant local
code.
WARNING – Risk of fire or electric shock. Install this kit only in the
luminaires that have the construction features and dimensions shown in the
photographs and/or drawings and
where the input rating of the retrofit kit does not exceed the input rating of
the luminaire.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to
edges of sheet metal or other sharp objects.
- Disconnect power at the source before installation, inspection or removal. Do not simply switch off the fixture.
- Not intended for use with emergency exit fixtures or emergency exit lights.
- Not for use with luminaire ballast.
- Do not use if the product is damaged.
- This lamp is non-dimmable. Not for use with dimmers.
- Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
- “This luminaire has been modified to operate LED lamps” shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance including re-lamping.
- Risk of fire or electric shock. Do not open or modify. No user-serviceable parts inside.
- This item is rated at 120-277V. The installer must determine whether line voltage 120-277V is available at the luminaire before installation.
- Before retrofitting, the installer must confirm the voltage of the branch circuit is 120V. If the voltage of the branch circuit exceeds 120V, the lamp cannot be installed.
- Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead, installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors.
- SUITABLE FOR DAMP LOCATIONS. The units covered in this report are intended to retrofit a maximum one lamp, Type IC or Type non-IC recessed luminaires without a diffuser. Not for use where directly exposed to the weather or water.
- Complies with Part 15 of FCC. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received including interference that may cause undesired operation.
- No external weight or mechanical force should be applied to the lamp or components.
- THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY UL
OR AUTHORITIES HAVING JURISDICTION.
INSTALLATION
- Read all WARNINGS before continuing this section.
- Ensure the fixture is 120-277V.
- Make sure POWER IS TURNED OFF AT THE SOURCE.
- Remove lens if applicable, and remove cover and lamp.
- Before rewiring, check the ballast type and refer to the relevant diagram.
- Before rewiring, please check the number of lamps per fixture and refer to the relevant diagram.
- If the fixture is new without ballast, please refer to Cf. Diagram 2.
- If the fixture ballast type is electronic, please refer to Cf. Diagram 3.
- If the fixture ballast type is magnetic please refer to Cf. Diagram 4.
- Install the lamp into the wired lamp holder.
- Visibly affix “Modification Sticker” and reinstall housing cover and lens if applicable.
- Return power back to source and installation is now complete.
Diagram 1 – Minimum lamp compartment dimensions
Diagram 2 – New fixture without ballast wiring
Diagram 3 – Electronic ballast fixture wiring modification
Diagram 4 – Magnetic ballast fixture wiring modification
www.greencreative.com – info@greencreative.com – Tel / Fax: 866-774-5433 – / GREENCREATIVELED / GClightingLED / GREEN-CREATIVE