ENCELIUM 56364 SSU System Support Unit
INSTALLATION INSTRUCTIONS
PRODUCT SAFETY
When using electrical equipment, basic safety precautions should always be
followed, including the following:
READ THESE INSTRUCTIONS BEFORE USING THIS PRODUCT.
- Do not let power supply cords touch hot surfaces.
- Do not mount near gas or electric heaters.
- Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
- The use of accessory equipment is not recommended by Encelium as it may cause an unsafe condition.
- Do not use this equipment for other than the intended use.
SAVE THESE INSTRUCTIONS.
GETTING STARTED
Overview
The System Support Unit (SSU) serves as the database server for all data and
stores all system settings and parameters, including attributes for zones,
fixtures, sensors, and controllers. In addition, the SSU maintains multiple
set-points for light levels, time schedules, occupancy sensor timeouts, and
demand response or load shedding. Each Encelium X Lighting Control System
requires one SSU, typically located in a building’s electrical room.
WIRED SYSTEM OVERVIEW
GreenBus technology makes wiring fast and error-free, since it’s intuitive to install. With Encelium X, you can control DALI devices exclusively or a mixture of GreenBus and DALI.
Green Bus
DALI
WIRELESS SYSTEM OVERVIEW
This illustration shows how each component is easily integrated into the Encelium X Lighting Control System.
INSTALLATION
The SSU requires power from a 100 to 240 VAC, 50/60 Hz, 300 W Emergency Circuit (Preferred), Non-Emergency Circuit (Acceptable), and one or two CAT-5 data connections.
MOUNTING OPTION
-
Install the mounting brackets ~1.03 m (3.37 ft) from the floor. Space the left and right brackets 465 mm (18.3 inches) apart from the top hole centers or 449.5 mm (17.7 inches) from the inside edges.
-
The SSU shall be installed in dry, indoor locations ONLY. The SSU shall be installed into a Pollution Degree 2 (or better) environment. The SSU may be installed into a standard 483 mm (19 inches) rack mount.
ELECTRICAL CONNECTIONS
SSU Wiring
Encelium X Ethernet connections to Wired or Wireless Managers, SSU, Ethernet
Switch, and Tenant LAN.
Green Bus
DALI
TROUBLESHOOTING
There are no user-serviceable parts inside. For detailed information about how to set-up, install, use, and maintain Encelium hardware and software, please visit: help.encelium.com
Copyright © 2022 Digital Lumens, Incorporated. All rights reserved. Digital
Lumens, the Digital Lumens logo, We Generate Facility Wellness, SiteWorx,
LightRules, Lightelligence, Encelium, the Encelium logo, Polaris, GreenBus and
any other trademark, service mark, or tradename (collectively “the Marks”) are
either trademarks or registered trademarks of Digital Lumens, Inc. in the
United States and/or other countries, or remain the property of their
respective owners that have granted Digital Lumens, Inc. the right and license
to use such Marks and/or are used herein as nominative fair use. Due to
continuous improvements and innovations, specifications may change without
notice.
DOC-000444-00 Rev C 02-22
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>