General
Auxiliary relay HR 10 is a junction box containing a contactor and a rotary
switch. It is used to control external1 to 3 phase loads such as oil burners,
immersion heaters and pumps.
HR 10 can be set to three positions via the rotary switch:
- In ”Off” the load is disconnected.
- In ”On” the load is connected.
- In ”Auto” the load is controlled via external control signal.
Connection
NOTE
All electrical connections behind covers secured by screws must be carried out
by an authorised electrician.
Electrical n out in accordance with the stipulations in force.Use suitable
screwdriver
Install the enclosed unions in suitable positions. If the outer diameter of
the cable is not 10–13 mm, replace the enclosed unions with others that are
suitable for the outer diameter of the cable.
FUSE
Recommended max fuse 16A.
Fuse 10 A entails a short-circuit current Type “1”, which means that no
measures need to be performed on HR10.
Fuse over 10 A entails a short-circuit current Type “2”, which means that
contactor in HR10 must be replaced.
CONNECT THE POWER SUPPLY TO CONTACTOR -K1 AS FOLLOWS:
At 3 phase load:
L1 to -K1:1, L2 to -K1:3, L3 to -K1:5
and N to -K1:13.
At 1 phase load:
L1 to -K1:1 and N to -K1:13. (Voltage between -K1:1 and -K1:13 must be 230
VAC.)
CONNECT THE LOAD TO CONTACTOR -K1 AS FOLLOW
At 3 phase load:
L1 to -K1:2, L2 to -K1:4, L3 to -K1:6
and N to -K1:14.
At 1 phase load: L1 to -K1:2 and N to -K1:14.
EXTERNAL CONTROL SIGNAL MUST BE CONNECTED AT 230 VAC TO TERMINAL BLOCK
-X1:1 (PHASE) AND -X1:2 (N).
The electrical circuit diagram is at the end of this Installer handbook
Technical
specifications
Load | Resistive | Inductive |
---|---|---|
400V 3N ~ 50Hz | 10 A | 5 A |
230V ~ 50Hz
230V 2 ~ 50Hz
| 13.5 A| 6.5 A
| |
---|---|---
Width| mm| 125
Height| mm| 125
Depth| mm| 75
Read More About This Manual & Download PDF:
References
- Polski producent podgrzewaczy wody i kotłów CO | Producent zasobników pionowych C.W.U | Biawar
- Wärmepumpen und effiziente Energiesysteme von KNV
- Nibe-evan.ru
- Vølund Varmeteknik - varmeløsninger og varmepumper
- Polski producent podgrzewaczy wody i kotłów CO | Producent zasobników pionowych C.W.U | Biawar
- Wärmepumpen und effiziente Energiesysteme von KNV
- Nibe-evan.ru
- Vølund Varmeteknik - varmeløsninger og varmepumper
- Värmepumpar för en enkel och hållbar vardag | NIBE
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>