Hanna HI8633 Multi-range EC Meters User Manual
- June 5, 2024
- HANNA
Table of Contents
HI8633 · HI8733
Multi-range EC
Meters
HI8633 Multi-range EC Meters
- Automatic temperature compensation (ATC) (HI8733)
- Help feature
- On-screen user guides
- One-point calibration
- One-point calibration
- Waterproof
The HI8633 and HI8733 conductivity meters have been designed for use in areas
of production and quality control.
These meters utilize four-ring potentiometric probes that offer greater
versatility over typical amperometric designs. These rugged probes are made of
PVC and are ideal for indoor as well as outdoor measurements. HI8733’s
conductivity measurements can be automatically temperature compensated by
using the HI76302W probe with built-in temperature sensor.
Temperature compensation for HI8633 is performed by manual adjustment.
Specifications | H18633 | F H18733 |
---|---|---|
Range | .o to 199.9 pS/cm; 0 to 1999 pS/cm 0.00 to 19.99 mS/cm; 0.0 to 199.9 | |
mS/cm | 0.0 to 199.9 pS/cm; 0 to 1999 pS/cm 0.00 to 19.99 mS/cm; 0.0 to 199.9 |
mS/cm
Resolution| 0.1 pS/cm; 1 pS/cm 0.01 mS/cm; 0.1 mS/cm| 0.1 pS/cm; 1 pS/cm 0.01
mS/cm; 01 m5/cm
Accuracy (025°C/77°F)| ±1% F.S. (excluding probe error)| ±1% ES. (excluding
probe error)
Calibration| manual, one-point through EC knob| manual, one-point through EC
knob
Temperature Compensation| manual, 0 to 50°C (32 to 122°F) with = 2913/°C|
automatic, 0 to 50°C (32 to 122°F) with adjustable from 0 to 2.5%/°C
Probe| HI76301D four-ring conductivity probe with DIN connector and 1 m (3.3′)
cable (included)| I76302W four-ring conductivity H
probe with internal temperature sensor, DIN connector, and 1 m (3.3′) cable
(included)
Battery Type / Life| 9V / approximately 100 hours of continuous use| 9V /
approximately 100 hours of continuous use
Environment| 0 to 50°C (32 to 122°F); RH max 100%| 0 to 50°C (32 to 122°F); RH
max 100%
Dimensions| 145 x BO x 36 mm (5.7 x 3.1 x 1.41| 145 xI30 x 36 mm (5.7 x 3.1 x
1.41
Weight| 230 g (5.1 oz.)| 230 g (5.1 oz.)
Ordering Information| HI8633 is supplied with HI76301D conductivity solution
sachet, battery, instructions and rugged
HI8733 is supplied with HI76302W conductivity
calibration solution sachet, battery, instructions| probe,121380 pS/cm HI70030
calibration carrying case.
probe, 12E30 pS/cm HI70030, and rugged carrying case.
Accessories| HI710007 blue shockproof rubber boot
HI710008 orange shockproof rubber boot
www.hannainst.com
EC solutions begin on page 5.34
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>