SEALEVEL SeaLINK PIO-96 USB to 96 Channel TTL Digital Interface Adapter User Manual
- June 5, 2024
- SEALEVEL
Table of Contents
- SEALEVEL SeaLINK PIO-96 USB to 96 Channel TTL Digital Interface Adapter
- Introduction
- What’s Included
- Advisory Conventions
- Optional Items
- For High-Current, High-Voltage Applications
- Software Installation
- Physical Installation
- Digital I/O Interface
- Programming the SeaLINK PIO-96
- Electrical Characteristics
- Specifications
- Example Circuits
- Appendix A – Troubleshooting
- Appendix B – How To Get Assistance
- Appendix C – Silk Screen – 8205 PCB
- Appendix D – Compliance Notices
- Warranty
- Trademarks
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SEALEVEL SeaLINK PIO-96 USB to 96 Channel TTL Digital Interface Adapter
Introduction
The SeaLINK PIO-96, part number 8205, provides an easy method for interfacing
common digital I/O circuitry via any computer’s USB port. Typical applications
include control/monitoring of TTL devices (e.g., LEDs, small solenoids, small
relays) and interfacing to solid-state relay racks (SSRs) for high-power AC or
DC loads.
The SeaLINK PIO-96’s 96 digital I/O channels are accessed via four 50-pin
header connectors with industry-standard pinout. Each header provides 24 bits
of digital I/O divided into three eight-bit groups. Each eight-bit group may
be individually configured via software command as input or output to best
match your particular application requirements.
The SeaLINK PIO-96 is designed to be used under Windows 98/ME/2000/XP. The
SeaI/O API (Application Programmer Interface) included in Sealevel’s software
provides a variety of useful high-level function calls implemented in a
Windows dynamic link library (DLL). This API gives access to the SeaLINK
PIO-96’s I/O from Windows-based platforms such as Visual C++. In addition to
the API, SeaI/O includes an ActiveX control along with sample code and
utilities to simplify software development.
Other Sealevel SeaLINK USB to Digital I/O Products
Model No. | Part No. | Description |
---|---|---|
SeaLINK PIO-48 | (P/N 8203) | – 48 TTL Inputs/Outputs |
SeaLINK PLC-16 | (P/N 8206) | – 8 Form C Outputs/ 8 Opto-isolated Inputs |
SeaLINK REL-16 | (P/N 8207) | – 16 Reed Relay Outputs |
SeaLINK ISO-16 | (P/N 8208) | – 16 Opto-isolated Inputs |
SeaLINK DIO-16 | (P/N 8209) | – 8 Reed Outputs/8 Opto-isolated Inputs |
What’s Included
The Sealink PIO-96 is shipped with the following items. If any of these items are missing or damaged, please contact Sealevel for replacement.
- Sealink PIO-96 Module
- 5V Power Supply
- USB Cable for Connecting Sealink PIO-96 to Host
Advisory Conventions
-
Warning
The highest level of importance used to stress a condition where damage could result to the product, or the user could suffer serious injury. -
Important
The middle level of importance used to highlight information that might not seem obvious or a situation that could cause the product to fail. -
Note
The lowest level of importance used to provide background information, additional tips, or other non-critical facts that will not affect the use of the product.
Optional Items
Depending upon your application, you are likely to find one or more of the following items useful for interfacing the SeaLINK PIO-96 to real-world signals. All items can be purchased from our website (www.sealevel.com) or by calling 864-843-4343.
For TTL Applications
-
Terminal Block Kit – (Part Number KT107)
Kit includes the TB07 screw terminal block and CA167 ribbon cable for connecting one of the SeaLINK PIO-96’s 50-pin header connectors to your I/O. 6” Snap track and DIN rail clips are included for DIN rail mounting. -
IDC 50 to IDC 50 Pin 40″ Ribbon Cable (Part Number CA167)
Interfaces each of the SeaLINK PIO-96’s 50-pin header connectors. -
Simulation/debug module (Part Number TA01)
Module allows monitoring status of output pins and controlling state of input pins. An LED corresponding to each port bit illuminates to indicate state. Eight position DIP switches are used to generate input status changes.
For High-Current, High-Voltage Applications
-
IDC 50 to IDC 50 Pin Ribbon Cable (Part Number CA167)
40” cable connects the SeaLINK PIO-96 to solid-state relay racks equipped with 50-pin header interface. -
IDC 50 to IDC 50 Pin Ribbon Cable (Part Number CA135)
40” cable connects the SeaLINK PIO-96 to solid-state relay racks equipped with 50-pin edge connector. -
Solid State Relay Racks:
-
Quad six position relay rack (Part Number PB24HQ)
Relay rack can accept up to six QSSRs for a total of 24 channels. Features a 50-pin header connector for easy interface via 50-conductor ribbon cables. -
Quad four-position relay rack (Part Number PB16HQ)
The relay rack can accept up to four QSSRs for a total of 16 channels. Features a 50-pin header connector for easy interface via 50-conductor ribbon cables.
-
-
Quad Solid State Relay Modules:
-
AC Input (Part Number IA5Q)
Provides 4 channels of discrete I/O interface to monitor AC inputs up to 140V @ 10mA. -
DC Input (Part Number IB5Q)
Provides 4 channels of discrete I/O interface to monitor DC inputs from 3.3V to 32V. -
AC Output (Part Number OA5Q)
Provides 4 channels of discrete I/O interface to control AC outputs up to 140V @ 3A. -
DC Output (Part Number OB5Q)
Provides 4 channels of discrete I/O interface to control DC outputs up to 60V @ 3A.
-
-
Simulation/debug module (Part Number TA01)
Module simulates the operation and load characteristics of a standard 24-channel relay rack. An LED corresponding to each port bit illuminates to indicate state. Eight position DIP switches are used to generate input status changes.
Software Installation
Windows Installation
IMPORTANT:
Do not connect the SeaLINK PIO-96 Adapter to the host USB device until the
software has been fully installed.
WARNING:
Only users running Windows 7 or newer should utilize these instructions for
accessing and installing the appropriate driver via Sealevel’s website. If you
are utilizing an operating system prior to Windows 7, please contact Sealevel
by calling 864.843.4343 or emailing
support@sealevel.com to receive access to the
legacy driver download and installation instructions.
-
1. Begin by locating, selecting, and installing the correct software from the Sealevel software driver database.
2. Select the Part Number (#8205) for your adapter from the listing. -
1. Select the download for the SeaIO Classic for Windows (Software: SeaIO Classic V5 – Windows -Sealevel.) The setup file will automatically detect the operating environment and install the proper components. Next (depending on your browser) select the ‘Run this program from its current location’ or ‘Open’ option. Follow the information presented on the screens that follow. During setup, the user may specify installation directories and other preferred configurations. This program also adds entries to the system registry that are necessary for specifying the operating parameters for each driver. An uninstall option is also available to remove SeaIO files and registry/INI file entries from the system.
2. Go to the “Add New Hardware Wizard” in the Control Panel.
3. When the Wizard asks if you want Windows to search for the new hardware, choose “No, I want to select the hardware from a list.”
4. Scroll through the list of categorized hardware and select ‘SeaIO Devices.’ If this is the first SeaIO device you may need to select ‘Other Devices’ and ‘Sealevel Systems, Inc.’ instead of ‘SeaIO Devices.’
5. Click “Next.”
6. Select the card model and press “Next.”
7. The Wizard will guide you through a few more informational prompts; continue to click “Next” until it is completed.
8. Your card’s resource assignments may be adjusted through the Device Manager (if, for instance, you need to change the I/O port address Windows assigned when you installed the card).
9. Windows software installation is complete.
Physical Installation
The SeaLINK PIO-96 can be installed in any open USB port.
- Simply connect the SeaLINK PIO-96 to your USB port with the supplied cable.
- The software drivers installed during setup will automatically recognize and configure the device.
- You should see one or more “New Hardware Found” windows, indicating the actual device being created.
- Next, view your system’s Device Manager.
- You should have a new ‘SeaIO 8205’ in the SeaI/O Device heading indicating the installation was successful.
The SeaLINK PIO-96 is now ready for use.
Digital I/O Interface
The SeaLINK PIO-96’s 96 digital I/O channels are accessed via two industry- standard 50-pin header connectors. Each header provides 24 bits of digital I/O divided into three eight-bit ports. Each port may be individually configured via software command as input or output.
50-pin Header Connector
You will need to open the SeaLINK PIO-96’s enclosure to access the four header
connectors P2, P3, P4, and P5. To open, remove the four screws found on the
bottom panel of the unit. Once cables are connected to the headers reassemble
the enclosure with the cables exiting the opening on the back panel of the
unit.
Each of the four 50-pin connectors has the following pinout which is
compatible with a wide variety of solid-state relay racks:
Programming the SeaLINK PIO-96
Sealevel’s SeaI/O software is available to assist in the development of reliable applications for the Sealevel Systems family of digital I/O adapters. Included in Sealevel’s software and drivers are driver functions for use in accessing the I/O as well as helpful samples and utilities.
Programming for Windows
The SeaI/O API (Application Programmer Interface) provides a variety of useful
high-level function calls implemented in a Windows dynamic link library (DLL).
The API is defined in the help file (Start/Programs/SeaIO/SeaIO Help) under
“Application Programmers Interface.” This help file also includes in the SeaIO
software provides detailed information dealing with installation/removal of
the software and information about latency, logic states, and device
configuration. For C language programmers we recommend using the API to access
the SeaLINK PIO-96. If you are programming in Visual Basic, using the ActiveX
control included with SeaI/O is advised.
Samples and Utilities
A variety of sample programs and utilities (both executable and source code)
are included in the software for the SeaI/O. Further documentation on these
samples can be found by selecting “Start/Programs/SeaIO/Sample Application
Description.” If need further assistance in programming the SeaLINK PIO-96,
please contact Sealevel’s Tech Support at
864-843-4343 or email:
support@sealevel.com.
Electrical Characteristics
The SeaLINK PIO-96 uses 74ABT245 octal bi-directional transceivers to provide TTL input/output capabilities. Each bit is pulled to +5V through a 10K ohm pull-up resistor to insure each bit is at a known state when not driven.
Specifications
Inputs
Logic High | Min 2VDC |
---|---|
Logic Low | Max 0.8VDC |
Outputs
Logic High | Min 2VDC @ 32 mA |
---|---|
Logic Low | Max 0.5VDC @ 64 mA |
Temperature Range
Operating | 0°C – 70°C |
---|---|
Storage | -50°C – 105°C |
Power Consumption
Supply line | +5 VDC | +5VDC |
---|---|---|
Rating | 400 mA (no load) | 2.4A (Max) |
Example Circuits
Appendix A – Troubleshooting
Following these simple steps can eliminate most common problems.
- Install software first. After installing the software then proceed to add the hardware. This places the required installation files in the correct locations.
- Read this manual thoroughly before attempting to install the adapter in your system.
- Use Device Manager under Windows to verify proper installation.
- Use the SeaIO Control Panel applet or the Device Manager’s property page for card identification and configuration.
If these steps do not solve your problem, please call Sealevel Systems’ Technical Support, 864-843-4343. Our technical support is free and available Monday through Friday from 8:00 AM – 5:00 PM, Eastern Time. For email support contact support@sealevel.com.
Appendix B – How To Get Assistance
Begin by reading through the Trouble Shooting Guide in Appendix A. If assistance is still needed please see below.
- When calling for technical assistance, please have your user manual and current adapter settings. If possible, please have the adapter installed in a computer ready to run diagnostics.
- Sealevel Systems provides an FAQ section on its website. Please refer to this to answer many common questions. This section can be found at http://www.sealevel.com/faq.asp.
- Sealevel Systems maintains a Home page on the Internet. Our home page address is www.sealevel.com. The latest software updates, and newest manuals are available via our FTP site which can be accessed from our home page.
- Technical support is available Monday to Friday from 8:00 AM to 5:00 PM, Eastern Time. Technical support can be reached at 864-843-4343. For email support contact support@sealevel.com.
- RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE WILL BE ACCEPTED. AUTHORIZATION CAN BE OBTAINED BY CALLING SEALEVEL SYSTEMS AND REQUESTING A RETURN MERCHANDISE AUTHORIZATION (RMA) NUMBER.
Appendix C – Silk Screen – 8205 PCB
Appendix D – Compliance Notices
Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for Class A digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in such case the user will be required to correct the interference at the user’s expense.
EMC Directive Statement
Products bearing the CE Label fulfill the requirements of the EMC directive (89/336/EEC) and of the low-voltage directive (73/23/EEC) issued by the European Commission. To obey these directives, the following European standards must be met:
- EN55022 Class A – “Limits and methods of measurement of radio interference characteristics of information technology equipment”
- EN55024 – “Information technology equipment Immunity characteristics Limits and methods of measurement”.
WARNING:
- This is a Class A Product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures to prevent or correct the interference.
- Always use cabling provided with this product if possible. If no cable is provided or if an alternate cable is required, use high-quality shielded cabling to maintain compliance with FCC/EMC directives.
Warranty
Sealevel’s commitment to providing the best I/O solutions is reflected in the Lifetime Warranty that is standard on all Sealevel-manufactured I/O products. We are able to offer this warranty due to our control of manufacturing quality and the historically high reliability of our products in the field. Sealevel products are designed and manufactured at its Liberty, South Carolina facility, allowing direct control over product development, production, burn- in and testing. Sealevel achieved ISO-9001:2015 certification in 2018.
Warranty Policy
Sealevel Systems, Inc. (hereafter “Sealevel”) warrants that the Product shall conform to and perform in accordance with published technical specifications and shall be free of defects in materials and workmanship for the warranty period. In the event of failure, Sealevel will repair or replace the product at Sealevel’s sole discretion. Failures resulting from misapplication or misuse of the Product, failure to adhere to any specifications or instructions, or failure resulting from neglect, abuse, accidents, or acts of nature are not covered under this warranty. Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase. The customer agrees to ensure the Product or assume the risk of loss or damage in transit, to prepay shipping charges to Sealevel, and to use the original shipping container or equivalent. The warranty is valid only for the original purchasers and is not transferable. This warranty applies to Sealevel manufactured Products. Products purchased through Sealevel but manufactured by a third party will retain the original manufacturer’s warranty.
Non-Warranty Repair/Retest
Products returned due to damage or misuse and Products retested with no
problem found are subject to repair/retest charges. A purchase order or credit
card number and authorization must be provided in order to obtain an RMA
(Return Merchandise Authorization) number prior to returning the Product.
How to obtain an RMA (Return Merchandise Authorization)
If you need to return a product for warranty or non-warranty repair, you must
first obtain an RMA number. Please contact Sealevel Systems, Inc. Technical
Support for assistance:
- Available Monday – Friday, 8:00AM to 5:00PM EST
- Phone 864-843-4343
- Email support@sealevel.com
Trademarks
Sealevel Systems, Incorporated acknowledges that all trademarks referenced in this manual are the service mark, trademark, or registered trademark of the respective company.
References
- Sealevel - I/O & Computing Products, Engineering and Manufacturing
- FAQs - Sealevel
- Software Driver Search - Sealevel
- Software: SeaIO Classic V5 - Windows - Sealevel
- Where is the description of the SeaIO API? - Sealevel
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>