VIGORPOOL Captain 1200 Portable Power Station User Manual
- June 5, 2024
- VIGORPOOL
Table of Contents
CAPTAIN 1200 USER MANUAL
DISCLAIMER
CONGRATULATIONS!
Thank you for purchasing your new VIGORPOOL product. VIGORPOOL strives to
create innovative clean energy products with unique designs and excellent
perfor mance. VIGORPOOL always try best to make products simple and easy to
use.
WARNING
This user manual contains instructions for safety, operation, and maintenance.
It’s essential to read the entire user manual carefully before setup and use.
Failure to read and follow instructions and warnings in this document may
damage the product and personal property and cause serious injury.
This document and all other collateral documents are subject to change at the
sole discretion of VIGORPOOL INC. For any updates, please visit vigorpool.com.
What’s in the Box
Product Specifications
BATTERY INFO
Model: | VP21 |
---|---|
Capacity: | 25.6V 50Ah 1280Wh |
Cell Chemistry: | life, |
Lifecycle: | 3500 cycles to 80%+ capacity |
Management System: | Overcharge Protection, Over Discharge Protection, Overload |
Protection, Short Circuit Protection, Over Current Protection, High- Temperature Protection, Low-Temperature Protection
OUTPUT
AC Output (4): | 120V-60Hz 1 QA, Total 1200W (Surge 2400W) |
---|---|
AC Parallel Inter face (Being Connected): | 120V-60Hz, 1200W |
USB-A Output (2): | 5V-3A, 9V-2A, 12V-1.5A, 18W Max per port, Total 36W |
USB-C Output (2): | 5V/9V/12V/15V-3A, 20V-5A 1 00W Max per port, Total 200W |
DC5521 Output (2): | 12V-3A 36W Max per port, Total 72W |
Car Output: | 12V-10A, 120W Max |
(2 x DC5521 Output+ Car Output: Total 120W) | |
Wireless Output: | 10WMax |
INPUT
AC Input: | 120V-60Hz 10.5A |
---|---|
Anderson Input: | 12-56V-12A Max, 400W Max |
GENERAL
Weight: | About 32.62Ibs (14.8kg) |
---|---|
Dimensions (LxWxD): | 15.59 x 9.44x 11.06 in (39.6 x 24.0 x 28.1 cm) |
Discharging Temperature: | -10-40°C |
Charging Temperature: | 0-40°C |
Certification: | FCC, UL, CE, UKCA, PSE, MIC, RoHS |
Warranty: | 24 Months |
Optional Accessory: | 400W Solar Panel, 200W Solar Panel, 1 00W Solar Panel |
APP Control: | Yes |
Start Guides for Users
Using Captain 1200
- Long press the power button, the LCD screen & product on; short press the power button, the LCD screen & product off.
- If your phone fails to connect with the device, please long press the loT reset button.
- With the power button turned on, short press the U5B button/ DC button/ AC button to use those ports; short press again to turn them off.
- With the power button turned on, short press the light button to get four modes: weak light, strong light, 505, and flashing.
Please note: For power saving, the VIGORPOOL CAPTAIN 1200 AC output will be turned off automatically after 12 hours if power usage remains under 20W. DC & U5B output will be turned off automatically after 12 hours if power usage remains under SW.
Details of Captain 1200
LCD Screen
ICON CONTENTS | ICON TYPE |
---|---|
Input Status | Indicates that the CAPTAIN 1200 is charging. There is a display |
of the remaining
charge time and a display of the current power input.
Output Status| Indicates that the CAPTAIN 1200 is powering/charging a device.
There is a display
of the remaining discharge time and the current power output.
Power Display| Shows the current battery capacity.
Anderson Port| Indicates that the CAPTAIN 1200 is being charged with a solar
panel or a car.
AC Input| Indicates that the wall charger is being used to charge the CAPTAIN
1200.
Fan Run| Indicates that CAPTAIN 1200 current temperature is too high and needs
to
cool down. At this time, there will be some fan rotation sound.
Wi-Fi| 1. Press and hold the lo T button until the Wi-Fi icon lights up.
2. Once the WiFi icon is lit, you can connect your phone to the device using
the VIGORPOOLApp.
3. Press and hold the lo T button until the icon disappears to turn off WiFi.
Ports Usage status| Indicates the usage status of each port.
Multiple Recharging Methods
Wall Charging | Car Charging |
---|---|
About 2 Hours | About 14 Hours |
Solar Panels | Electric Generator |
About 4 Hours | About 2 Hours |
WALL CHARGING:
The CAPTAIN 1200 uses fast charging technology with a maximum input power of
800W; it can be charged up to 80% in 1.5 hours and fully charged in 2 hours.
In addition, you can select fast charging 800W, slow charging 400W(silent
charging), or custom charging through the App. The default input power is
800W.
SOLAR PANEL CHARGING:
Users can choose VIGORPOOL 400W solar panel, 200W solar panel or 100W solar panel to charge the CAPTAIN 1200.The DC input voltage range is 12.56 the maximum current is 12A, and the maximum charging power is 400\W.le full sunlight, the CAPTAIN 1200can be charged with two 200\W solar panels, which will take about 4 hours to complete a full charge
–
CAR CHARGING:
The CAPTAIN 1200can be charged with a car lt supports 12V car charging and
takes about 14 hours to fully charge. Charge using the car charger after
you’ve started the car to avoid failure to start due to insufficient car
battery.
In addition, please make sure that the Cr Changing Input Port and the Car
Charging Cable are in good condition. VIGORPOOL takes no responsibility for
any losses or damages caused by failure to follow instructions.
ELECTRIC GENERATOR CHARGING:
The CAPTAIN 1200 can be charged in about 2 hours using a traditional generator
Connect Two Captain 1200
Connect the parallel port of the CAPTAIN 1200 through the parallel cable and turn the AC button on until the parallel graph on the LCD is lit, indicating a successful parallel connection. AC output power provides up to 2400\W continuous output, using a capacity of up to 2560\Wh.Users can use the AC port on either product. Please avoid using load devices that exceed the rated power of 2400W lease note The parallel cable needs to purchase additional
Use of APP
You can view energy forecasting, state monitoring and estimation, and anomaly detection via the VIGORPOOL App. For more details, please download it on the App Store or Google Play and check our official website to get the connect steps https://VIGORPOOL.com/pages/VIGORPOOL-pp
Notes on Boost
Traditional power stations will shut off if their continuous power output rate is exceeded. However, the CAPTAIN 1200 AC inverter boost function can boost the power output from 1200W to 1800/ without overload protection power failure You can therefore run most of the higher-powered devices without a problem, When using the Boost feature, please keep the following in mind
- Pay special attention to the charging state.
- When using an appliance that requires between 1200\W1800\%, only use that one appliance. Trying to run multiple AC devices while using the boost feature could result in voltage fluctuations that could damage appliances over time
- 4f the 1200\W1800W appliance you are attempting to power with the CAPTAIN 1200 exceeds the unit’s surge voltage limit of 2400/when starting the appliance, you may not be able to power that appliance
uninterruptible Power Supply (UPS)
This product supports an uninterruptible power supply (UPS) function. The
unit’s battery will be bypassed while fully charged and connected to the grid
via AC charging cable. In other words, anything you plug into the AC ports
will pull directly from the grid rather than the battery. In a power outage,
this product can automatically switch to the battery-powered mode within 1
Oms.
Note: This function does not support Om’s switching. Therefore, it is not
recommended to be used a s a UPS for highly sensitive equipment, such as data
servers and workstations without confirming compatibility or proper testing
before use. It is also recommend ed to only use the UPS function for one
device at a time to avoid overload protection. VIGORPOOL assumes no
responsibility and is therefore not liable for data loss or damage caused by
the use of this product in setups that it was not intended for and the
disregard of this recommendation
Safety Guidelines
- DO NOT immerse the product in water or get it wet.
- DO NOT put the product near heat sources, such as a fire or heater, while using or storing.
- DO NOT pierce the product casing with a nail or other sharp object, use a hammer to break it open, or step on it.
- DO NOT let the product make contact with corrosive objects.
- DO NOT attempt to disassemble this product in any way.
- DO NOT forcibly lock the fan during use or place the product in an unventilated or dusty area.
- DO NOT clean the product with water directly. Instead, use a dry cloth to gently clean it.
- DO NOT replace any components of the product without any official VIGORPOOL permissions.
- Please contact the official VIGORPOOL channels to get more information if you want to replace any components.
- DO NOT dispose of the battery directly in a battery recycling box. You should contact a professional recycling company for further processing.
- DO NOT put the product in an area where children or pets can reach it.
How to Store or Use
- For long-term storage (more than 3 months), the battery needs to be maintained at 50% of the rated capacity (recharged once every 3 months), stored in a dry and cool place, and kept away from fire, heat sources, and corrosive substances.
- To extend the life of the product, it’s better to recharge the product before the power drops 15%.
- The operating temperature of the VIGORPOOL power station is -10-40°C (14-104°F), and the storing temperature is -10-35°C (14-95°F).
Troubleshooting
Icon Indicator | Problem | Solution | Error code |
---|---|---|---|
USB Output Overload Protection or Short Circuit | Turn off the USB output and |
remove the abnormal load. After 10 seconds, the power station should function
as usual.| E001
| DC Output Overload Protection or Short Circuit| Turn off the DC output and
remove the abnormal load. After 10 seconds, the power station should function
as usual.| .
E002
| AC Output Overload Protection or Short Circuit| Turn off the AC output and
remove the abnormal load. After 10 seconds, the power station should function
as usual.| E003
| AC Input Over Current Protection or Short Circuit| The abnormal state will
be cleared automatically after 10 seconds. After that, press the AC input
over-current protector button and unplug the charging cable. Then the power
station should function as usual.| E004
| Solar Panel Input Current Protection or Short Circuit| The abnormal state
will be cleared automatically after seconds. Then the power supply will be
restored.| E005
| Wireless charging not working| Remove the abnormal load. After 10 seconds,
the wireless function as usual.| E006
| High-Temperature Protection| The power supply can be restored automatically
after the battery cools down.| E007
| Low -Temperature Protection| The power supply can be restored automatically
after the battery temperature returns to safe operating temperatures.| is
E008
If you are still having problems, please feel free to contact us at support@vigorpool.com. For additional information, check our official website: www.VIGORPOOL.com.
Frequently Asked Questions
-
What devices can VIGORPOOL CAPTAIN 1200 power?
A: VIGORPOOL CAPTAIN 1200 can power essential devices less than 1200W (or one device up to 1800W using the inverter boost feature). The total wattage of devices being powered should be under 1200W unless using the inverter boost feature.
Please refer to your device specification before purchase. -
What is the VIGORPOOL CAPTAIN 1200 power station lifespan?
A: The VIGORPOOL CAPTAIN 1200 uses lithium iron phosphate battery technology. After 3500 cycles of use, the VIGORPOOL CAPTAIN 1200 power station’s capacity will drop to 80%. Lifespan also depends on how the power station is used, maintained, etc. -
Is the VIGORPOOL CAPTAIN 1200 waterproof?
A: The VIGORPOOL captain 1200 is not waterproof, please stay away from water sources. -
Can I use and charge my VIGORPOOL CAPTAIN 1200 simultaneously?
A: Yes, all of our products support pass-through charging. But we don’t suggest using it this way very frequently as it will reduce the battery life. -
Can I take my VIGORPOOL CAPTAIN 1200 on a plane?
A: Unfortunately, you cannot. According to FAA regulations, any battery you take on board should not exceed 1 00Wh. External chargers or power banks are also considered a battery. They should not surpass a capacity of 27000mAh, or in other words, 1 00Wh. -
Is the VIGORPOOL equipped with an MPPT controller?
A: All VIGORPOOL models have an MPPT controller. -
Can I use third-party solar panels to recharge my VIGORPOOL CAPTAIN 1200?
A: We don’t suggest using third-party solar panels because VIGORPOOL’s warranty does not cover any damage caused by third-party solar panels. -
Can I jump-start a car using my VIGORPOOL CAPTAIN 1200?
A: Our Captain 1200 can’t jump-start a car, but it can charge the dead batteries of your car through a car charge cable. -
How to determine if my VIGORPOOL CAPTAIN 1200 is charging?
A: The LCD display will show the remaining charging time when charging, and the battery percentage power indicator will start to rotate.
FCC Caution
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different. from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20 cm between the radiator and your body.
FCCID:2ASSKVP211200
UL2743 Caution
VA photovoltaic panel as input for charging the internal battery shall be provided with an inverter and/or a charge controller in accordance with UL 1741 or UL 62109-1 ;The external power supply shall be a power source in accordance with the Standard UL 60950-1 and CAN/CSA C22.2 No. 60950-1, or UL 1310 and No. 1, CAN/CSA C22.2 No. 223, or No.1, CAN/CSA C22.2 No. 223; A vehicle adapter that complies with the enclosure and input contacts requirements in the Standard for Vehicle Battery Adapters, UL 2089, and Power Supplies, CAN/CSA C22.2 No. 107.1 The connector plug shall incorporate a fuse or other protective device having a current rating not greater than 15 A. INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
IMPORTANT SAFETY INSTRUCTIONS
WARNING – When using this product, basic precautions should always be followed, including the following:
- Read all the instructions before using the product.
- To reduce the risk of injury, close supervision is necessary when the product is used near children.
- Do not put fingers or hands into the product.
- Use of an attachment not recommended or sold by a power pack manufacturer may result in a risk of fire, electric shock, or injury to persons.
- To reduce the risk of damage to the electric plug and cord, pull the plug rather than the cord when disconnecting the power pack.
- Do not use a battery pack or appliance that is damaged or modified. Damaged or modified batteries may exhibit unpredictable behavior resulting in fire, explosion or risk of injury.
- Do not operate the power pack with a damaged cord or plug, or a damaged output cable.
- Do not disassemble the power pack, take it to a qualified service person when service or repair is required. Incorrect reassembly may result in a risk of fire or electric shock.
- To reduce the risk of electric shock, unplug the power pack from the outlet before attempting any instructed servicing.
- WARNING – RISK OF EXPLOSIVE GASES. To reduce the risk of battery explosion, follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use in the vicinity of the battery. Review cautionary marking on these products and on engines.
- PERSONAL PRECAUTIONS
- Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes.
- Wear complete eye protection and clothing protection. Avoid touching your eyes while working near the battery.
- If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters the eye, immediately flood the eye with running cold water for at least 10 minutes and get medical attention immediately.
- NEVER smoke or allow a spark or flame in the vicinity of the battery or engine.
- Be extra cautious to reduce risk of dropping a metal tool onto the battery. It might spark or short-circuit a battery or another electrical part that may cause an explosion.
- When charging the internal battery, work in a well-ventilated area and do not restrict ventilation in any way.
- Under abusive conditions, liquid may be ejected from the battery; avoid contact. If contact accidentally occurs, flush with water. If liquid contacts the eyes, additionally seek medical help. Liquid ejected from the battery may cause irritation or burns.
- Do not expose a power pack to fire or excessive temperature. Exposure to fire or temperature above 130°C may cause an explosion. The temperature of 130°C can be replaced by a temperature of 265°F.
- Have servicing performed by a qualified repair person using only identical replacement parts. This will ensure that the safety of the product is maintained.
SAVE THESE INSTRUCTIONS
Batteries or battery packs must be recycled or disposed of properly. When this product has reached the end of ts useful life, it should not be disposed of with other household waste. The Waste Electrical and Electronic Equipment Regulations require it to be separately collected so that it can be treated using the best available recovery and recycling techniques. This will minimize the impact on the environment and human health from soil and water contamination by any hazardous substances, decrease the resources required to make new products and avoid using up landfill space. Please do your part by keeping this product out of the municipal waste stream! The “wheelie bin” symbol means that it should be collected as “waste electrical and electronic equipment”. You can return an old product to your retailer when you buy a similar new one. For other options, please contact your ocal council.
VIGOR POOL
TM and© 2022 VIGORPOOL Inc. All rights reserved.
VIGORPOOL.COM
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>