Raypak B-R206A Digital Asme Propane Gas Commercial Swimming Pool Heater Owner’s Manual

June 6, 2024
Raypak

Raypak B-R206A Digital Asme Propane Gas Commercial Swimming Pool Heater

Specifications

  • Model: ASME Digital/Millivolt Atmospheric Heater
  • Heater Models Available: B-R206A, B-R266A, B-R336A, B-R406A
  • Input MBTUH (kWh): 199.5 (58.47), 266.0 (77.96), 332.5 (97.45), 399.0 (117)
  • Cabinet Width: 20″, 23″, 26″, 29″
  • Flue Diameter: 6″, 7″, 8″, 9″
  • Indoor Drafthood Height: 61.63″ to 64.5″
  • Shipping Weights: 212 lbs to 269 lbs

Product Usage Instructions

Installation

  1. Ensure the heater is placed on a level, combustible surface if applicable.
  2. Properly vent the heater according to the venting options available.

Operation

  1. Turn on the gas control train using the combination control valve.
  2. Select the desired firing mode (on/off).

Maintenance

  1. Regularly inspect the burners and clean if necessary.
  2. Check for any gas leaks or unusual sounds during operation.

FAQ

  1. What fuel types are compatible with this heater?
    This heater is compatible with natural gas and propane (minimum grade HD-5).

  2. Can this heater be used indoors and outdoors?
    Yes, this heater is designed for both indoor and outdoor use.

  3. How should I select the appropriate model for my needs?
    Choose the model based on your required heating capacity and cabinet width.

Product Submittal for ASME Digital/Millivolt Atmospheric Gas Pool Heaters
Models B-R206A – B-R406A

  • Job:
  • Engineer:
  • Contractor:
  • Prepared by:
  • Date:
  • Model:
  • Indoor/Outdoor

Features

  • 82% Efficiency
  • ASME Code Bronze Headers
  • ASME Code Copper-Fin Tube
  • 75 lb. Pressure Relief Valve
  • Small Footprint
  • Unitherm Governor Anti-Condensation Control
  • Indoor/Outdoor
  • Proudly Assembled in the USA

Digital model with outdoor top shown

Heat exchanger

  • ASME HLW stamped; 100 PSIG MAWP
  • National Board registered
  • Bronze headers
  • Finned tubing
    • Copper (standard)
    • Cupronickel (optional, digital units only)
  • ASME Steel tube sheet
  • Silicone O-rings
  • Fixed high limit, auto reset, 160°F
  • Fixed high limit, manual reset, 135°F
  • 75 PSIG Pressure relief valve
  • Water connections
    • Right hand (standard)
    • Left hand (optional-field change)
  • Flow configuration (two-pass)

Controls

Millivolt option

  • Standing pilot ignition
  • Thermopile generator
  • Single mechanical temperature control
  • Flame rollout switch
  • High limit control
  • On/off switch
  • Water pressure switch

Digital option

  • 120/240V, 60Hz, 1 Ph power supply
  • 120/240/24V Transformer
  • 100% Pilot shut-off; lockout (propane only)
  • Electronic, intermittent ignition pilot (IID)
  • High limit control
  • On/off switch
  • Flame rollout switch
  • Water pressure switch
  • Dual electronic temp sensor
  • Digital display with diagnostics

Gas control train

  • Q Fuel
    • Natural gas
    • Propane (minimum grade HD-5)
  • Combination control valve
  • On/off firing

Construction

  • Front controls
  • ANSI Z21.56 design certified
  • Stainless steel burners
  • Polytuf powder coat finish
  • Indoor/outdoor
  • Can be installed on a combustible surface
  • Venting
    • Outdoor stackless top (included)
    • D-2 Power vent indoor, loose (optional for digital models, see 1000.70)
    • D-10 Indoor draft diverter, loose (optional)
    • D-13 High wind top (optional, outdoor)
    • Outdoor high wind stack (optional)

Other options

  • PoolStat cover/lock kit
  • X-10 Restraint bracket (Florida code requirement)

DIMENSION

Raypak-B-R206A-Digital-Asme-Propane-Gas-Commercial-Swimming-
Pool-Heater-FIG- \(4\)

Heater

Model

|

MBTUH

(kWh) Input

| Dimensions in. (mm)| Shipping Weights lbs. (kg)
---|---|---|---
Cabinet Width (A)| Flue Dia. (B)| Indoor Drafthood (C)| Draft Relief Height

(J)

| Heater with Stackless Top| Indoor Drafthood

B-R206A

| 199.5| 20| 6| 61.63| 11.75| 212| 14
(58.47)| (508)| (152)| (1565)| (298)| (96.16)| (6.35)

B-R266A

| 266.0| 23| 7| 62| 11| 235| 16
(77.96)| (584)| (178)| (1575)| (279)| (106.59)| (7.26)

B-R336A

| 332.5| 26| 8| 63| 10.63| 250| 19
(97.45)| (660)| (203)| (1600)| (270)| (113.39)| (8.62)

B-R406A

| 399.0

(117)

| 29

(736)

| 9

(229)

| 64.5

(1638)

| 12.13

(308)

| 269

(122)

| 21

(9.52)

Notes:

  1. Model number suffix indicates pilot type (E = digital, M = millivolt), fuel type (P = propane, N = natural gas) and tube material (C = copper, X = cupronickel). Example: Model number B-R406A-EN-C indicates a unit with digital (IID) ignition using natural gas with copper tubes.
  2. Ratings are for natural gas and elevations up to 2,000 feet above sea level. Reduce input 4% for each 1,000 feet above sea level when installed at over 2,000 feet elevation.

Raypak, Inc. 2151 Eastman Avenue, Oxnard, CA 93030 805-278-5300 www.raypak.com
Effective: 09-01-20 Replaces 6000.38F

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Raypak User Manuals

Related Manuals