Raypak B-R206A Millivolt Atmospheric Gas Pool Heater Owner’s Manual
- June 13, 2024
- Raypak
Table of Contents
Product Submittal for ASME
Digital/Millivolt Atmospheric
Gas Pool Heaters
Models B-R206A – B-R406A
B-R206A Millivolt Atmospheric Gas Pool Heater
Job:____
Engineer:
Contractor:____
Prepared by:
Date:____
Model:____ Indoor/Outdoor
Features:
- 82% Efficiency
- ASME Code Bronze Headers
- ASME Code Copper-Fin Tube
- 75 lb. Pressure Relief Valve
- Small Footprint
- Unitherm Governor Anti-Condensation Control
- Indoor/Outdoor
- Proudly Assembled in the USA
Digital model with outdoor top shown
Heat exchanger
-
ASME HLW stamped; 100 PSIG MAWP
-
National board registered
-
Bronze headers
-
Finned tubing
Copper (standard)
Cupronickel (optional, digital units only) -
ASME Steel tube sheet
-
Silicone O-rings
-
Fixed high limit, auto reset, 160°F
-
Fixed high limit, manual reset, 135°F
-
75 PSIG Pressure relief valve
-
Water connections
Right hand (standard)
Left hand (optional-field change) -
Flow configuration (two-pass)
Controls
Millivolt option
-
Standing pilot ignition
-
Thermopile generator
-
Single mechanical temperature control
-
Flame rollout switch
-
High limit control
-
On/off switch
-
Water pressure switch
Digital option -
120/240V, 60Hz, 1 Ph power supply
-
120/240/24V Transformer
-
100% Pilot shut-off; lockout (propane only)
-
Electronic, intermittent ignition pilot (IID)
-
High limit control
-
On/off switch
-
Flame rollout switch
-
Water pressure switch
-
Dual electronic temp sensor
-
Digital display with diagnostics
Gas control train
-
Fuel
Natural gas
Propane (minimum grade HD-5) -
Combination control valve
-
On/off firing
Construction
- Front controls
- ANSI Z21.56 design certified
- Stainless steel burners
- Polytuf powder coat finish
- Indoor/outdoor
- Can be installed on combustible surface
- Venting
Outdoor stackless top (included)
D-2 Power vent indoor, loose (optional for digital models, see 1000.70)
D-10 Indoor draft diverter, loose (optional)
D-13 High wind top (optional, outdoor)
Outdoor high wind stack (optional)
Other options
PoolStat cover/lock kit
X-10 Restraint bracket (Florida code requirement)
Heater
Model| MBTUH (kWh) Input| Dimensions in. (mm)| Shipping
Weights lbs. (kg)
---|---|---|---
Cabinet
Width
(A)| Flue Dia.
(B)| Indoor Drafthood
(C)| Draft Relief
Height
(J)| Heater with
Stackless Top| Indoor Drafthood
B-R206A| 199.5
(58.47)| 20
(508)| 6
(152)| 61.63
(1565)| 11.75
(298)| 212
(96.16)| 14 (6.35)
B•R266A| 266.0
(77.96)| 23
(584)| 7
(178)| 62
(1575)| 11
(279)| 235
(106.59)| 16 (7.26)
B-R336A| 332.5
(97.45)| 26
(660)| 8
(203)| 63
(1600)| 10.63
(270)| 250
(113.39)| 19 (8.62)
B-R406A| 399.0
(117)| 29
(736)| 9
(229)| 64.5
(1638)| 12.13
(308)| 269
(122)| 21 (9.52)
Notes:
- Model number suffix indicates pilot type (E = digital, M = millivolt), fuel type (P = propane, N = natural gas) and tube material (C = copper, X = cupronickel). Example: Model number B-R406A-EN-C indicates a unit with digital (IID) ignition using natural gas with copper tubes.
- Ratings are for natural gas and elevations up to 2,000 feet above sea level. Reduce input 4% for each 1,000 feet above sea level when installed at over 2,000 feet elevation.
Raypak, Inc. 2151 Eastman Avenue, Oxnard, CA 93030 805-278-5300 www.raypak.com
Part No.: 241897 Rev. 1
Effective: 09-01-20
Replaces 6000.38F
Documents / Resources
|
Raypak B-R206A Millivolt Atmospheric Gas Pool
Heater
[pdf] Owner's Manual
P-M266A-MP-C 009927, P-R266A-MP-C 009209, B-R206A, B-R206A Millivolt
Atmospheric Gas Pool Heater, Millivolt Atmospheric Gas Pool Heater,
Atmospheric Gas Pool Heater, Gas Pool Heater, Pool Heater, Heater
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>