deli 4083 Deposit Safe Box
Welcome to use our series products of safes (cabinets) and safe deposit boxes. Please read the instruction manual carefully before use, and operate correctly according to the instructions.
Product Unpacking
Check that product appearance is intact after unpacking the box and checking all accessories. Please contact the dealer if anything is broken or missing.
Remark: For products without internal door products inside the box, There is no internal door keys attached.
Product Schematic
First Use
- Push the door lock slide cover down to the limited position and press the emergency lock flip cover;
- Insert one of the door lock keys and one of the emergency keys into the corresponding key hole, respectively, turn the emergency key clockwise, then turn the door lock key clockwise to open the door.
Battery Installation
- Put the four 5# batteries into the internal battery compartment located on the backside cover of the door according to the correct polarity. The display shows it scans back and forth from left to right after the power is supplied, then it shows “good” after the scan is completed, and it will enter the standby state;
- Insert the door lock key, press the key “#” to wake up, and enter the factory password “12345678” when the display shows “——-“;
- Press the key “#” to confirm, the display shows “OPEN”, please turn the door lock key clockwise within 6 seconds to open the door.
Password Setting
The factory password of this product is “12345678”. Please reset your personal password before use to ensure safety.
- Press the key “#” to wake up, enter the factory password “12345678”, and the display shows “OPEN”. The door can be opened;
- Within 25 seconds after the display is turned off, press the Reset key on the backside cover of the door and the display shows “set”;
- Enter a new password of 1-8 digits, press the key “#” to confirm, the display shows “into”, and the new password is set;
- The display shows the new password again for 1 second and then returns to the standby state. Tip: Verify the new password after the password is set, and then lock the door after confirmation.
Door Closing Operation
- Close the door;
- Turn the door lock key counterclockwise and pull it out.
Hidden Code Function
- After pressing the key “#” and before entering the password, the hidden code function can be switched by pressing the key “*”. When the hidden code function is valid, the digits which are entered afterwards will not be displayed, but they will be replaced by “口”;
- The digit display is automatically restored after this function is turned on.
Deleting Incorrect Password
If an incorrect password is entered during the operation, it can be deleted by using the key “” before pressing the key “#” to confirm. The last digit entered can be cleared each time the key “” is pressed.
Alarm Function
Wrong password alarm
The display shows “Error” each time an incorrect password is entered, then “———” will be displayed again, and the password can be entered again at this time. The display shows the alarm horn symbol and will alarm for one minute if a wrong password is entered consecutively for three times. Entering the correct password during the alarm can stop the alarm.
Vibration alarm
The vibration alarm function is turned on when the display shows “ALERT ON” if the key “0” is pressed in the standby state; The display shows the alarm horn symbol and “———” and will alarm for one minute when the product is vibrated by external force. Entering the correct password during the alarm can stop the alarm.
Battery Replacement
When the voltage of the batteries drops to a certain level, the display will show “Lo bat” after the password is entered each time, indicating that the battery voltage is insufficient, please replace with new batteries as soon as possible. (It is recommended that you use 5# alkaline batteries)
Emergency Opening
- Please provide power by using the external battery compartment when the batteries are depleted and the operation cannot be made. Insert the plug of the external battery compartment into the external power supply socket located below the electronic panel, and enter the correct password to open the door;
- Please use the emergency key to open the door when the electronic system fails or the password is forgotten. The way to open the door is the same as the first use.
Querying Door Opening Record
- First open the door by entering the password. You can query the previous door open records by pressing key “0” or “8” when the display shows “OPEN”. Each record is displayed on two screens;
- The first screen is displayed at first: password type (for example: “PASS-1” / “PASS-2”) and record number (for example: “N0 01” – “N0 58”);
- Then the second screen is displayed: the door opening date and time of this record;
- Record page turning: in the state of record query, if the key “0” has been pressed, record number +1 to turn the page; if the key “8” has been pressed, record number -1;
- If the key is not pressed within 3 seconds, it will exit the query state and return to the standby state;
- The system can save the latest 58 records at most. When there are more than 58 records, each time a new record is added, the oldest record will be overwritten. Each record contains the following information: year, month, day, hour, minute, record number (1=last record, 2=last second record, … 58=last 58th record), password type (1=personal password, 2=administrative password).
System Date Modification
-
In the standby state, press the key “*” to enter the state of modifying the system date and time;
-
Enter “year”, “month”, “day”, “hour”, “minute” (10 digits in total) by pressing the digit keys directly. It will be automatically confirmed after the corresponding space digit flashes. Then it will save the new time and exit the setting state, and return to the standby state;
-
Press the key “*” to go back one space during the setting and re-enter one;
-
The system will identify the validity of the entered digits, and it will not confirm the invalid values that exceed the range. The valid ranges of each parameter are as follows:
Year: 00~99, Month: 01~12, Day: 01~31, Hour: 00~23, Minute: 00~59; -
Note: The system cannot automatically distinguish a month of 31 or 30 days and a leap month’s maximum days when modifying the date. The user must ensure that the date they enter is meaningful and avoid artificial errors such as “February 30th”;
-
If the modification is not finished and no key is pressed within 8 seconds, it will exit the modification state (the modified value is invalid) and return to the standby state;
-
The system is embedded with a perpetual calendar from 2000 to 2099, which will automatically switch to a month of 31 or 30 days and convert to a leap year when timing.
Precautions for Use
- Do not put the user’s manual, door lock keys, emergency keys and external battery compartment in the box, they should be stored in other safe place;
- The battery should be taken out to prevent the leakage of liquid from damaging the electronic system if the product is left unused for a long time;
- Always fix the cabinet to a solid concrete wall for safe keeping;
- Do not store too much cash and valuables when unattended or without a remote alarm device.
Common Faults and Troubleshooting
Symptoms | Causes | Troubleshooting |
---|
No any response when pressing the digit keys to enter the password
|
The batteries are depleted
| Use the external battery compartment or the emergency key to open the
electronic code lock and replace the batteries
Battery polarity reversed| Insert the batteries properly
Circuit board failure| Please contact
department
| the| maintenance
The door lock key cannot be inserted in or removed
| The key is inserted in the
wrong direction
| Please contact
department
| the| maintenance
There are foreign objects in
the key hole
| Remove foreign objects in the key hole
The key is not turned to the
limit
| Please reinsert in the correct direction
The door cannot be opened when the electronic code lock has been
opened
| Turn the handle for more than 7 seconds, and the electronic
lock has been reset
| Enter the password again and turn the handle to the limit within 7 seconds
The alarm does not sound| The batteries are depleted| Please replace the
batteries
Battery polarity reversed| Insert the batteries in the correct way
Product Warranty Card
Commodity Information
| Commodity Name| | Factory Date|
---|---|---|---|---
Commodity Model| | Production
Date
|
Customer Information| Company Name| | | Contact|
Address| | | Phone|
Sales Information| Seller Name| | | Contact|
Address| | | Phone|
| Sales Date| | | Invoice No.|
Maintenanc
e Record
| Fault Description| Maintenance Result| Customer
Signature
| Maintenance Person
Signature
| Date
| | | | |
| | | | |
DELI GROUP CO., LTD.
Add: Deli Industrial Park, Ninghai, Zhejiang Service Hotline: 400-185-0555
Http://www.nbdeli.com MADE IN CHINA