VIKING E-35-IP/EWP Entry Phone with Analog Video Camera User Guide
- June 4, 2024
- VIKING
Table of Contents
- Introduction
- Features
- Applications
- Specifications
- VoIP SIP System Compatibility
- Camera Specifications
- Definitions
- Features Overview
- Installation
- Camera Wiring and Adjustments
- Typical Installation on SIP Based VoIP Phone System
- PC Requirements
- PC Programming
- Programming Features Index
- Programming Features
- Operation
- Troubleshooting
- Using a Viking Model RC-4A for Secure Remote Relay Control
- Related Products
- Warranty
- TWO YEAR LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
VIKING E-35-IPEWP Entry Phone with Analog Video Camera User Guide
Introduction
The E-35-IP VoIP Entry Phone is designed to provide quick and reliable hands free communication for SIP VoIP phone systems with PoE. The E35-IP Entry Phone can be programmed from any Touch Tone phone, PC, or remotely using a static IP address. The Entry phones can dial up to 5 programmable numbers. On-board 2 Amp relay contacts are provided for activating doorstrikes or gate controllers. An optional RC-4A Secure Relay Controller can also be used.The E-35-IP Entry Phone will flash the “Call” LED during dialing and automatically light the LED when the call is answered. All programming parameters, including phone numbers and location numbers, are stored in non-volatile memory, requiring no batteries. The unit is PoE powered.
Standard Flush Mount
The E-35-IP-EWP shares all the features of the E-35-IP in addition to Enhanced Weather Protection (EWP) for outdoor installations where the unit is exposed to precipitation or condensation. EWP products are designed to meet IP66 standards and may feature foam rubber gaskets, sealed connections, gel-filled butt connectors, as well as potted circuit boards with internally sealed, field-adjustable trim pots and DIP switches for easy on-site programming. For more information on EWP, see DOD 859.
Shown in Optional
VE-5×5 Surface Mount Box
Installation requires the assistance of a Network Administrator / IT Technician. !
Features
- Built-In high resolution analog NTSC color video camera with wide viewing angle, tilt/swivel adjustments and wide operating temperature
- Automatic polling and programming software included
- 2 Amp relay contacts for door/gate or SL-2 strobe light control
- Blue “Call” LED indicator
- SIP compliant (see page 2 for compatible SIP servers and IP phone systems)
- Outbound Proxy, Authentication ID, Peer to Peer, VLAN Tagging
- PoE powered (class 1, <4 watts)
- Automatic Noise Canceling (ANC) feature for proper operation in noisy environments
- VoIP eliminates the need for “Push to Talk” mode
- T-10 Torx security screws for added security
- Can be used with optional RC-4A Secure Relay Controller (DOD 582)
- Hands free operation
- Marine grade 316 stainless steel prevents corrosion
- Laser Etched graphics on stainless steel models
- Programmable to dial up to 5 numbers on busy or ring no answer
- Cycles through backup phone numbers on busy or no-answer
- Optional Enhanced Weather Protection (EWP), EWP products are designed to meet IP66 Ingress Protection Rating, see DOD 859
- Hangs up on busy signal, time-out or touch tone command
- Remotely programmable
- Extended temperature range (-40°F to 140°F)
- Replacement board available
- Volume adjustments for microphone and speaker
- E-35-IP is flush mountable using the included rough-in box or can be surface mounted using an optional VE-5×5 Surface Mount Box (DOD 424)
- Optional PB-100 Polling System available (DOD 232)
- Optional SL-2 or BLK-4-EWP strobe light kit available (DOD 242/653)
- Diagnostics (for testing mic, speaker & relay)
Applications
- Gate Entrance
- Parking ramps/lots
- ATM machines
- Medical centers
- Lobbies
- Entryways
- Stadiums
- Convention centers
- Public access areas
Specifications
Power: PoE class 1 (<4 watts)
Maximum Sound Pressure: 95 dB SPL @ 1m.
Dimensions: Overall-5” x 5” x 2.25” (127mm x 127mm x 57mm),
Plastic Electrical Box -4” x 4” x 2.12” (102mm x 102mm x 54mm)
Shipping Weight: 2 lbs (0.9 Kg)
Operating Temperature: -40°F to 140°F (-40° C to 60° C)
Humidity – Standard Products: 5% to 95% non-condensing
Humidity – EWP Products: Up to 100%
Audio Codecs: G711u, G711a, G722
Network Compliance: IEEE 802.3 af PoE, SIP 2.0 RFC3261, 100BASE-TX with
auto cross over
Regulatory Compliance: FCC Part 15 and Canada ICES-3 Class A
Connections: (1) RJ45 10/100 Base-T, (6) gel-filled butt connectors (3M
Scotchlok UR2)
(See page 3 for camera specifications)
VoIP SIP System Compatibility
For compatibility and vendor specific detailed configuration instructions, see the Viking VoIP SIP System Compatibility List, DOD 944. To open and download this PDF file:
Scan the QR code below to open and download the Viking VoIP SIP System
Compatibility List
– OR –
- Go to www.vikingelectronics.com and enter 944 in the search box
- Click Application Note (DOD 944) to open and download the PDF
Important: Exclusion from this list means only that compatibility has not
been verified, it does not mean
incompatibility. If you have questions, please call Viking Electronics at
715-386-8861.
Camera Specifications
- Power: 6-22V DC 150mA (12V DC UL Listed adapter included)
- Image Sensor: 1/4” color CMOS
- Video Output: 1 VP-P composite, NTSC, 75 ohms
- Resolution: 420 lines (640 x 480 @ 30fps / 307,200 pixels)
- Sensitivity: 0.025 LUX (50 IRE) F 1.2 3200K
- Lens: 2.1mm, conical pinhole
- FOV (Field of View): 80° Horizontal, 60° Vertical, 100° Diagonal
- Tilt/Swivel Adjustment: Vertical +/- 20°, horizontal +/- 30° (see Diagram A)
- IR Compatibility: This camera is equipped with an OLP (Optical Low Pass) filter to maintain correct video color in outside applications. The standard camera is NOT compatible with IR illuminators. If IR illumination is required, you will need to replace the existing camera with a Viking model VCAM-1IR. For more information, see DOD# 190.
- Maximum Wire Run Length: 1000 ft with *RG59/RG6 for video and CAT5 for power (1 pair) and entry phone audio (1 pair). 150 ft with CAT5E for video, power and entry phone audio (longer video runs are possible by using video balun transceivers, see Installation C, 2, page 5).
Note: RG59 or RG6 with solid center conductor and 95% bare copper braid shield.
Definitions
Client: A computer or device that makes use of a server. As an example,
the client might request a particular file from the server.
DHCP: Dynamic Host Configuration Protocol. In this procedure the network
server or router takes note of a client’s MAC address and assigns an IP
address to allow the client to communicate with other devices on the network.
DNS Server: A DNS (Domain Name System) server translates domain names
(ie: www.vikingelectronics.com) into an IP
address.
Ethernet: Ethernet is the most commonly used LAN technology. An ethernet
Local Area Network typically uses twisted pair wires to achieve transmission
speeds up to 1Gbps.
Host: A computer or device connected to a network.
Host Name: A host name is a label assigned to a device connected to a
computer network that is used to identify the device in various forms of
network communication.
Hosts File: A file stored in a computer that lists host names and their
corresponding IP addresses with the purpose of mapping addresses to hosts or
vice versa.
Internet: A worldwide system of computer networks running on IP protocol
which can be accessed by individual computers or networks.
IP: Internet Protocol is the set of communications conventions that
govern the way computers communicate on networks and on the Internet.
IP Address: This is the address that uniquely identifies a host on a
network.
LAN: Local Area Network. A LAN is a network connecting computers and
other devices within an office or building.
Lease: The amount of time a DHCP server reserves an address it has
assigned. If the address isn’t used by the host for a period of time, the
lease can expire and the address can be assigned to another host.
MAC Address: MAC stands for Media Access Control. A MAC address, also
called a hardware address or physical address, is a unique address assigned to
a device at the factory. It resides in the device’s memory and is used by
routers to send network traffic to the correct IP address. You can find
the MAC address of your E-35-IP phone printed on a white label on the top
surface of the PoE LAN port.
Router: A device that forwards data from one network to another. In order
to send information to the right location, routers look at IP Address, MAC
Address and Subnet Mask.
RTP: Real-Time Transport Protocol is an Internet protocol standard that
specifies a way for programs to manage the real-time transmission of
multimedia data over either unicast or multicast network services.
Server: A computer or device that fulfills requests from a client. This
could involve the server sending a particular file requested by the client.
Session Initiation Protocol (SIP): Is a signaling communications
protocol, widely used for controlling multimedia communication sessions such
as voice and video calls over Internet Protocol (IP) networks. The protocol
defines the messages that are sent between endpoints, which govern
establishment, termination and other essential elements of a call.
Static IP Address: A static IP Address has been assigned manually and is
permanent until it is manually removed. It is not subject to the Lease
limitations of a
Dynamic IP Address assigned by the DHCP Server. The default static IP Address
is: 192.168.154.1
Subnet: A portion of a network that shares a common address component. On
TCP/IP networks, subnets are defined as all devices whose IP addresses have
the same prefix. For example, all devices with IP addresses that start with
100.100.100. would be part of the same subnet. Dividing a network into subnets
is useful for both security and performance reasons. IP networks are divided
using a subnet mask.
TCP/IP: Transmission Control Protocol/Internet Protocol is the suite of
communications protocols used to connect hosts on the Internet. TCP/IP uses
several protocols, the two main ones being TCP and IP. TCP/IP is built into
the UNIX operating system and is used by the Internet, making it the de facto
standard for transmitting data over networks.
TISP: Telephone Internet Service Provider
WAN: Wide Area Network. A WAN is a network comprising a large
geographical area like a state or country. The largest WAN is the Internet.
Wireless Access Point (AP): A device that allows wireless devices to
connect to a wired network using Wi-Fi, or related standards. The AP usually
connects to a router (via a wired network) as a standalone device, but it can
also be an integral component of the router itself.
Wireless Repeater (Wireless Range Extender): takes an existing signal
from a wireless router or access point and rebroadcasts it to create a second
network.
When two or more hosts have to be connected with one another over the IEEE
802.11 protocol and the distance is too long for a direct connection to be
established, a wireless repeater is used to bridge the gap.
Features Overview
Front View of the E-35-IP
Rear (PCB) View of E-35-IP
Note: The front panel of the E-35-IP is mounted using security Torx screws to help prevent intruders from removing the panel and accessing the on board door strike/gate control relays. For applications requiring additional security, a Viking model RC-4A remote relay controller can be used. The relay controller is mounted securely inside the building and connected to the same LAN as the E-35-IP. For more information on the RC-4A Secure Relay Controller, see DOD 582.
Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inches. Cut off stripped wire ends before terminating.
Installation
Mounting the E-35-IP
The E-35-IP is designed to be flush mounted to the included 4” x 4” x 2” deep
plastic rough in box or surface mounted using an optional Viking model VE-5×5.
Important: The E-35-IP will NOT mount to a standard double gang box. The
plastic rough in box (part # 259576) may be purchased separately. Go to
www.vikingelectronics.com and click on
“Spare Parts”.
Optional VE-5×5 Surface Mount Box with black satin powder paint finish, not included (DOD 424). Optional VE-LIGHT kit (DOD 428) can be used to illuminate the faceplate when used with a VE-5×5
The optional VE-5×5 Surface Mount Box (above) is designed to be surface mounted to a single gang box, double gang box or VE-GNP Gooseneck Pedestal (shown right). For more information on the VE-5×5 and VE-GNP, see DOD 424.
Replacement IP Board Kit (Model E-1600-53A-IP)
This is a board (PCB) only kit, no chassis is included. This kit can be used to convert any Viking E-35 analog phone to a VoIP version. The kit can also be used to replace a damaged IP board in the field. This kit comes in standard and EWP version. The optional EWP version features foam rubber gaskets and boots, sealed connections, gel-filled butt connectors, as well as urethane or thermal plastic potted circuit boards, see DOD 859 for more information.
E-1600-53A-IP Board Specifications
Shipping Weight: .45 kg (1 lb)
Connections: (1) RJ45 10/100 Base-T, (3) optional gel-filled butt
connectors, (10) additional gel-filled butt connectors included with EWP
version only.
Note: These two red wires are only used on units with an Info button. When installing on a single button unit, cut off these two red wires and discard.
How to Replace Analog E-35 or E-35-EWP Circuit Boards:
Step 1. | Cut wires from J1 (10 pin connector) and J2 (2 pin connector). |
---|---|
Step 2. | Remove the two #6 phillips screws fastening the circuit board. |
Step 3. | Cut off any stripped wire ends from the replacement cable. |
Step 4. | Using the supplied gel-filled butt connectors, connect |
corresponding wires from replacement cable to the previously cut wires from the LED, Call switch, Speaker and Microphone. See FIGURE 1 above for wire color and polarity.
Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inches. Cut off stripped wire ends before terminating.
Camera Wiring and Adjustments
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from the AC outlet. It is recommended that a surge protector be installed to protect against such surges.
Using RG59 for Analog Video and CAT5 for Camera Power (Recommended)
Note: Up to 150 ft video cable run length can be achieved using CAT5E or CAT6 cable. Longer cable runs can be used if a passive or active video Balun transceiver is used on each end of the cable. Generally, passive transceivers can achieve up to 750 ft cable runs where active transceivers can achieve up to 3000 ft runs depending on cable type, etc. The type of video balun transceiver required is specific to your cable run length. For more information on video balun transceivers go to: www.northernvideo.com.
Note: The maximum camera power supply wire run length is 1000 ft of 24 gauge wire (CAT 5/6), longer runs are possible by doubling pairs, increasing the wire gauge or using up to a 22V DC 200mA power adapter.
Note: RG59 or RG6 with solid center conductor and 95% bare copper braid
shield.
Note: For ease of installation, a Viking Female “F” to Wire Converter
Cable can be used (Part # 261217) or “BNC” to wire converter cable (Part #
U213510) can be used. Go to
www.vikingelectronics.com and click on
“Spare Parts” to order.
Caution: When routing CAT5E or CAT6 cable, maintain a minimum distance of 3 ft from any parallel high voltage wire (110 VAC) and a minimum of 2 ft from crossing any high voltage wire. For installations where RF noise is expected (commercial applications) or wire runs are near high voltage (110 VAC) wires, a shielded video cable such as RG6 is recommended.
Using CAT5E or CAT6 for Analog Video and Camera Power (see Caution below)
Note: Up to 150 ft video cable run length can be achieved using CAT5E or CAT6 cable. Longer cable runs can be used if a passive or active video Balun transceiver is used on each end of the cable. Generally, passive transceivers can achieve up to 750 ft cable runs where active transceivers can achieve up to 3000 ft runs depending on cable type, etc. The type of video balun transceiver required is specific to your cable run length. For more information on video balun transceivers go to: www.northernvideo.com.
Note: The maximum camera power supply wire run length is 10 00 ft of 24 gauge wire (CAT 5/6), longer runs are possible by doubling pairs or increasing the wire gauge.
Note: RG59 or RG6 with solid center conductor and 95% bare copper braid shield.
Caution: When routing CAT5E or CAT6 cable, maintain a minimum distance of 3 ft from any parallel high voltage wire (110 VAC) and a minimum of 2 ft from crossing any high voltage wire. For installations where RF noise is expected (commercial applications) or wire runs are near high voltage (110 VAC) wires, a shielded video cable such as RG6 is recommended.
Using a Video Encoder to Convert the Analog NTSC Video to IP
Axis manufactures video servers that encode analog video signal for
transmission across IP network or the internet. The single channel model M7011
is shown. Supplied software allows you to access Axis units connected to the
network (auto-discovery) and program them via a web page interface. The video
can then be monitored from any location on the network.
For more information, go to www.axis.com
Axis Model M7011 shown
Adjusting the Camera
The camera can be tilted and rotated to your desired position. A portable
service (test) monitor can be used to determine the correct viewing angle
during installation.
Important: To prevent the edge of the faceplate from being viewed in the
video image, do not rotate the camera beyond 30 degrees or tilt beyond 20
degrees.
Typical Installation on SIP Based VoIP Phone System
Note: A PoE extender can be used for an additional 100 meters per extender. For longer runs (up to 2 km / 1.2 miles) a ethernet to fiber media converter can be used.
PC Requirements
- IBM compatible personal computer with: Windows 7, 8 or 10
- Adobe Acrobat Reader 8 or higher
- E-35-IP hardware Available LAN with PoE (class 1, < 4 watts)
- Ethernet cable ( CAT5 min.)
- 1 MB minimum free hard drive space for installation
- 16MB of free physical RAM
PC Programming
Download and install the programming software
- Go to www.vikingelectronics.com and enter E-35-IP in the search box
- Click E-35-IP in the search results
- Scroll down the page to Downloads, click IP Programming Software
- Install the programming software by saving or opening the file and then clicking on setup Viking IP Reprogramming
- Follow the prompts on your screen to complete software installation
- To start the Viking IP Programming application, click on the Viking IP Programming icon on your desk top. The Main screen will appear, allowing the user to program any E-35-IP connected to that LAN.
Note: PC must be connected to the same LAN as the E-35-IP.
Connect / Disconnect
Open the “Viking IP Programming” software on the PC and the start screen shown
below will appear. Any Viking IP phones that are connected to the network will
appear on the list. Simply select the Entry Phone on the list and click on the
“Connect” button at the bottom or double click the selected phone. If the
security code of the selected phone is still set to default (845464), the PC
software will not require entering a security code to connect to the phone.
Entry Phone’s have a default name of “VIKING_MK64_Vik02”, so if many phones
are connected to the same network that all have the default name, MAC
addresses must be used to identify each phone.
When finished programming, click on the “Disconnect” button at the bottom.
Closing the program will also automatically disconnect the unit.
Manually Muting SIP / Network Failure Alarm Beeps (3 beeps repeated every 30 seconds)
With the unit connected and powered (Green LED on and Yellow LED off or blinking) it will output 3 beeps every 30 seconds and turn the Call/Call Connected LED on and off once per second indicating a SIP registration failure, failure to receive an echo reply from pinged gateway or Ethernet connection failure. You can manually disable the beeps by pressing and holding the Call button for 5 seconds (2 beeps will then be heard) or by clicking the “Mute Alarm Until Next Failure” tab in the Viking IP programming software. The LED will continue to flash allowing you to trouble shoot the failure.
Configuring the E-35-IP Network Settings
Step 1.| Open the “Viking IP Programming” software on a windows PC that
is connected to the same LAN as the E-35-IP phone to be programmed.
---|---
**Step 2.| The window in the upper left corner of the menu will show
you each E-35-IP phone that is connected to that LAN. Select the unit with
the same MAC address shown on the label located on the top of the Ethernet
connector on the E-35-IP phone.
Step 3.| Click the “Connect” button. If a pop up window appears, enter
the unit’s security code (factory set to 845464 ) then click “OK”.
Step 4.| The program will then read and display the E-35-IP phone’s
IP and programming settings.
Step 5.| Click on the “IP Settings” tab.
Step 6.| Select the appropriate value Static IP Settings or DHCP for
“Set Unit IP Address via”. Note: changing the IP address will cause you to
have to reconnect to the unit. Enter the values for the fields in “if DHCP
fails” or “Static IP Settings” as needed.
Step 7.**| Set the “Unit Name”, “Logging / Time Server Settings” as
needed.
Step 8.
| Select Peer-Peer in the “SIP Server / Peer to Peer Settings” to use the unit in Peer to Peer mode. Select Server to register with a SIP registrar server and fill in the “Outbnd Proxy” (SIP Outbound Proxy Server Address, “ip:port”), “Authentic. ID” (SIP Authentication ID), “Username” (SIP Username,
Example 1: On-Premise SIP Phone System
(Panasonic TDE 100/200)
Example 2: Cloud Based Service Provider
(Voip.ms)
Example 3: Cloud Based Service Provider requiring Outbound Proxy and
Authentication ID (Ring Central)
Configuring E-35-IP VLAN Settings
Step 1. | Click on the “VLAN” tab |
---|---|
Step 2. | Disable or enable VLAN tagging by setting the value of “VLAN |
Tagging”.
Step 3.| Set the VLAN tag ID by selecting an integer (1 to 4094) in “ID
for all packets”.
Step 4.| Set the Priority Code Point (PCP) value for all not SIP and RTP
packets in the “PCP for all packets” input (0 is default, priorities are from
low to high: 0, 1, 2, 3, 4, 5, 6, 7). Set the “PCP for SIP packets” (3 is
default). Set the “PCP for RTP packets” (5 is default).
Manually Resetting the Security Code to Enter Programming
Step 1.| Power down the E-35-IP phone by disconnecting the LAN Cable
(RJ45 plug).
---|---
Step 2.| Press and hold the Call button, then reconnect the LAN Cable
(RJ45 plug).
Step 3.| Continue to hold Call button until you hear 2 beeps,
(approximately 6 seconds). Then release the button. The LED will remain off
for the first 3 seconds, flash slowly for 3 seconds then fast flash (after 2
beeps), indicating when to release button.
Step 4.| The security code is now reset to 845464 (factory default).
Step 5.| You can now enter programming by following the steps in section
A.
Manually Resetting All Network Parameters to Factory Default
Step 1.| Power down the E-35-IP phone by disconnecting the LAN Cable
(RJ45 plug).
---|---
Step 2.| Press and hold the Call button, then reconnect the LAN Cable
(RJ45 plug).
Step 3.
| Continue to hold the Call button until you hear 2 beeps, (approximately 6
seconds). Continue to hold Call button until you hear 4 more beeps,
approximately 6 seconds later, then release the button. The LED will remain
off for the first 3 seconds, flash slowly for 3 seconds (2 beeps), fast flash
for 6 seconds (4 beeps), then light steady indicating when to release button.
Step 4.| You can now enter programming by following the steps in section
A.
Programming Features Index
DESCRIPTION | Section | Page |
---|---|---|
Connect/Disconnect | A | 9 |
VLAN Settings | D | 11 |
Unit Name | 1 | 13 |
SIP Server | 2 | 13 |
Peer to Peer Settings | 3 | 13 |
Outbound Proxy | 4 | 13 |
Authentication ID | 5 | 13 |
Register Fails | 6 | 13 |
Speed Dial Numbers | 7 | 13 |
Security code (factory set to 845464) | 8 | 14 |
ID Number | 9 | 14 |
Access Code (1 – 6 digits, blank = disabled, factory set to 123456) | 10 | 14 |
Internal / External Relay (factory set to Internal) | 11 | 15 |
Relay Mode (Door Strike, Outbound Call, In / Outbound Call, Doorbell, LV-1K
Control, Ring, Ring Flash, factory set to Door Strike)| 12| 15
Relay Activation Command (1 or 2 digits, factory set to QQ) NOTE: Relay
Mode must be set to Door Strike| 13| 15
Relay Activation Time (0.5 – 99 seconds, factory set to 5 seconds)| 14| 15
Relay Buzz Volume (1 – 3 or Disabled, factory set to 3)| 15| 15
Relay Latch Commands (Enabled or Disabled, factory set to Enabled) NOTE:
Relay Mode must be set to Door Strike| 16| 16
Alternating Switch Action| 17| 16
Speaker Mode (ON, OFF / Silent Monitor or OFF until Answered, factory set to
ON)| 18| 16
Speaker Volume (0 – 9, factory set to 3)| 19| 16
Ring Volume (0 – 9, factory set to 5)| 20| 16
Microphone Volume (0 – 9, 0 = Auto, factory set to 5)| 21| 16
Talk/Listen Delay (VOX) (0.1 – 0.9 seconds, factory set to 0.5 seconds)| 22|
16
In-Band Audio Call Progress (Enabled, Disabled, factory set to Enabled)| 23|
16
In-Band Audio Detect Sensitivity (1 – 9, 1 = minimum, 9 = maximum, factory set
to 5, power cycle unit after setting)| 24| 16
Lap Counter (1 – 9 or Disabled, factory set to Disabled)| 25| 17
Call Length Time Out (disabled or 1 – 9 minutes, factory set to 3 minutes)|
26| 17
Inbound Call Mode (Disabled, Auto Answer, Auto Answer-Secure, Ring, Ring with
AGC, factory set to Auto Answer)| 27| 17
Ring Cadence (factorty set to Normal, 2 seconds on 4 seconds off)| 28| 17
Dial Next Number on RNA (Ring No Answer) (disabled, 1 – 9 = number of rings,
factory set to 7)| 29| 18
Dial Next Number on Busy (disabled or enabled, factory set to Enabled)| 30| 18
Send ID Numbers as (RFC 2833 or In Band DTMF, factory set to RFC 2833)| 31| 18
Call LED Mode (OFF, Entry Phone, Emergency Phone or Emergency Outbound only,
factory set to Entry Phone)| 32| 18
Call LED Control (Automatic or enter Q to light, factory set to Automatic)|
33| 18
Mute Current / Next Alarm| 34| 19
Permanent Alarm Mute (factory set to Alarm Tones Enabled)| 35| 19
IP Firmware| 36| 19
Unit Firmware| 37| 19
Import/Export| 38| 20
Clear Unit Settings| 39| 20
Clear IP Settings| 40| 20
Diagnostics (used to check mic, speaker and relay operations)| 41| 20
REX Input| 42| 20
Programming Features
Unit Name
Up to a 31 character unit name can be assigned to the E-35-IP being
programmed.
SIP Server
Enter the IP address or URL of your SIP server or service provider in this
field. The SIP server IP address is limited to 74 characters. Note: If an
alternate SIP server IP address is programmed, the IP address for the SIP
server and alternate SIP server will be limited to 31 characters. Note: If
outbound proxy is not required, enter the SIP server IP address into the
Outbnd Proxy field.
Peer to Peer Settings
When set to Peer to Peer mode, a SIP server is not used. The unit should be
programmed with a Static IP Address and Username, a password is not used.
Caller ID can be programmed if needed. Simply call the unit by entering the
programmed “username@192.168…(Static IP address for the unit)”. The static IP
address is normally programmed into a page button on the VoIP telephones.
Outbound Proxy
If your SIP provider requires an outbound proxy IP address enter it in the
Outbnd Proxy field. If outbound proxy is not required enter the SIP server IP
address into the Outbnd Proxy field. Note: If not required, this field must
match your SIP server IP address.
Authentication ID
If your SIP provider requires Authentication ID, enter it in the Authentic. ID
field. If Authentication ID is not required, leave this field blank.
Register Fails (Re-Resolve or Alternate Server)
When registered to a SIP server in the event that registration is lost you can
program the unit to re-resolve using the current SIP server IP address or
route pages through an alternate SIP server. With Alternate Server selected
enter the IP address of the alternate SIP server in the field next to the
Register Fails drop down box. Note: With an alternate SIP server IP address
programmed, the IP address for the SIP server and alternate SIP server will be
limited to 31 characters.
Note: A majority of the features below can also be Touch Tone (In-Band DTMF) programmed. See DOD 949.
Speed Dial Phone Numbers
Note: Up to 79 digits can be stored in each of the 5 speed dial phone
number positions.
The number programmed in the first location under “Speed Dial Numbers” is the
telephone or extension number that is dialed when the call button is pressed.
Additional numbers (if programmed) will be dialed when there is no answer and
the Dial Next No. on Ring No Answer feature is enabled. The E-35-IP will also
detect busy and move on (Dial Next Number on Busy Enabled). The E-35-IP will
cycle through the programmed Speed Dial numbers until answered.
Security Code
The security code allows the user/installer to program the E-35-IP. It is
recommended that the factory set security code be changed. Factory Setting:
845464
Note: The security code must be 6 digits and cannot include a Q or a #
ID Number:
The ID Number (1 – 6 digits) is used by emergency personnel to identify the
location of the caller and is given out when the receiving party presses a Q.
This ID number is transmitted as In-Band DTMF. This can be cleared out by
leaving the field blank. Factory Setting: 987654
Access Code
The Access Code is used for remotely operating the relay (Door strike, Mag-
Lock, etc) by calling into the unit. This code provides basic security and
only allows operation of the relays and not the ability to change any of the
programming parameters. Once entered, any of the “Remote Access Operation
Commands” can be used. The code can be 1 – 6 digits in length and cannot
contain a “Q” or “#” or match the numbers used for the security code. Simply
call the E-35-IP (set to auto-answer/auto-answer secure), the unit will
automatically answer the line and output one beep. You then enter the
programmed 1 – 6 digit access code, 2 beeps should be heard. You can now enter
any “Remote Access Operation Commands” (see page 21). This code will also
enable audio to/from the speaker and the caller. The access code can be cleard
(by leaving the field blank) if this additional level of security is not
required. Factory Setting: 123456.
Relay Internal / External
With the relay set to “Internal” the E-35-IP will activate its on board relay
for door strike / gate control. The Relay should be set to “External” for
higher security installations when using a Viking remote model RC-4A relay
controller to activate the door strike / gate controller (see page 22).
Factory Setting: Internal
Relay Mode
Door Strike Mode. When programmed for Door Strike Mode the relay will
momentarily activate for the reprogrammed relay activation time after
detecting the correct relay activation command (one or two digit touch tone)
from the called party.
Outbound Call Mode. When programmed for Outbound Call Mode the relay will
activate continuously for the duration of any outbound call from the
Emergency/Entry phone. This mode is useful for activating strobe lights for
Emergency VoIP phones.
Inbound/Outbound Call Mode. When programmed for Inbound/Outbound Call
Mode the relay will activate continuously for the duration of any inbound or
outbound call to or from the Emergency/Entry phone. This mode is useful for
turning on IR flood lights, VoIP phones with cameras, etc.
Doorbell Mode. When programmed for Doorbell Mode the relay will
momentarily activate the relay for the reprogrammed relay activation time on
any outbound call from the Emergency/Entry phone. This mode is useful for
activating a door chime, etc. When activating door chimes, a 0.5 – 1 second
relay activation time is recommended.
LV-1K Control Mode. When programmed for LV-1K Control Mode the relay will
activate continuously while the Emergency/Entry phone is powered and
registered to the SIP server. In the event the unit loses power and/or SIP
registration the relay will turn off, activating LV-1K’s flashing LED and
audible beep signals.
Ring Mode. When programmed for Ring Mode the relay will continuously
activate while the ringing extension is called. This mode is useful for
activating a Viking model SL-2 strobe light, etc.
Ring Flash Mode. When programmed for Ring Flash Mode the relay will
momentarily turn on and off in a 400ms on/off cadence while the ringing
extension is called. This mode is useful for activating a Viking LPL-1 Remote
Visual Indicator, etc.
Factory Setting: Door Strik
Relay Activation Command
The one or two digit code stored in the Relay Activation Command is the touch
tone command that the person being called must enter on their phone in order
to momentarily activate the relay to control a door strike, mag-lock, gate
controller, or other device. The code can contain the characters 0 – 9, # or
Q. The code cannot match a relay latching command (Q1, Q0). The code must be
entered while the remote phone is communicating with the Speaker phone.
Factory Setting: QQ
Relay Activation Time
The value stored in the Relay Activation Time is the amount of time the relay
will be energized after a correct momentary touch tone command is entered.
This number can range from 0.5 – 99 seconds. This also affects timing in
Doorbell Mode. Factory Setting: 5 seconds
Relay Buzz Volume
The relay activation tone is a buzzing sound that is heard from the speaker
when the door strike relay is activated.
After the called party enters the correct relay activation command, the called
party will hear 2 short confirmation beeps and the entry phone will output a
buzzing sound (relay activation tone) while the door strike relay is
activated. The tone (buzz) length will match the relay activation time up to a
maximum of 5 seconds. The tone (buzz) can be programmed to three different
volume settings 1 = Low, 2 = Medium, 3 = High or it can be disabled. Factory
Setting: 3
Relay Latch Commands
When set to “Enabled” the Remote Access Operation Commands (Q0 to Q1) to Un-
Latch or Latch the relay are enabled. These can be entered on a Inbound call
after the access code is dialed (if programmed).
When set to “Disabled” the Remote Access Operation Commands (Q0 to Q1) to Un-
Latch or Latch the relay are disabled. Disabling the Latch commands can be
useful in applications where you want to eliminate the possibility of
inadvertently entering a latch command leaving a gate open/closed, etc.
Factory Setting: Enabled
Alternating Switch Action (Panic Button Mode)
With Alternate Switch Action Enabled the CALL button alternately connects and disconnects calls. With Alternate Switch Action Disabled the CALL button connects calls only. Pressing the button again after the call has been initiated will not terminate the call. Factory Setting: Enabled
Speaker Mode
The Speaker Mode can be set to one of the following three modes. Factory
Setting: ON
OFF/Silent Monitoring Mode: In the “OFF” mode the speaker is disabled at all
times. However, the speaker can be enabled after communication has been
established by entering touch tone command “9#”. The speaker will remain on
for the duration of the call.
ON: In the “ON” mode the speaker is enabled during In-bound and Out-bound
calls.
OFF Until Answered: In the “OFF Until Answered” mode the speaker will
remain silent during dialing and will not turn on until the called party has
answered.
Speaker Volume
The Speaker volume can be set from 0 – 9, 0 = lowest volume setting, 9 =
highest volume setting. Adjusting this will set the volume level for
incoming/outgoing Phone calls. Factory Setting: 3
Ring Volume
When set to Ring or Ring with AGC, The E-35-IP will output a loud ring when it
is called. The level can be adjusted from 0 – 9. Factory Setting: 5
Microphone Volume / Automatic Noise Cancelling Mode
The microphone volume can be set from 1 – 9,1 = lowest volume setting, 9 =
highest volume setting. Alternatively the microphone can be placed in the
“Auto” Automatic Noise Cancelling mode. With the mic in the Auto mode, when
background noise increases, the mic gain will automatically decrease. When
background noise decreases the mic gain will automatically increase. The Auto
mode is useful in applications where the background noise level can change
drastically. Factory Setting: 5
Talk / Listen Delay (VOX)
This feature selects switching time between talk and listen modes (VOX
switching time). The Talk/Listen Delay can be programmed from 0.1 – 0.9
seconds. Factory Setting: 0.5 seconds
In-Band Audio Call Progress
The In-Band Audio Call Progress Detection can be set to enabled or disabled.
In-Band Audio Call Progress detection should be enabled in applications where
you are making an outbound call through your VoIP phone system and are relying
on In-Band analog audio for ringback or busy detection. Factory Setting:
Enabled.
In-Band Audio Detect Sensitivity
The In-Band Audio Detection level (Sensitivity) can be set from 1 – 9, 1 =
minimum setting, 9 = highest setting. Increasing or decreasing the sensitivity
may be required in applications where you are making an outbound call through
your VoIP
Factory Setting: 5
Lap Counter
With the lap counter disabled, if the E-35-IP is programmed to dial the next
number on ring-no-answer and/or busy signal, the E-35-IP will continuously
call its programmed phone numbers forever until the call is answered.
The lap counter is a programmable counter that determines how many times the E-35-IP will cycle through its list of up to 5 Speed Dial phone numbers, before it stops the dialing process and hangs up. When all of the programmed phone numbers have been dialed, the lap counter is incremented and the dialing process repeats. When the lap counter has been met, the dialing process stops and the E-35-IP hangs up. Factory Setting: Disabled
Call Length Timeout
This feature selects the maximum length of time that calls can be
connected. Programmable in increments of 1 minute up to a maximum of 9 minutes
or disabled. With the call length disabled, the E-35-IP must rely on a call
ended signal, busy signal, Ring No Answer limit, or touch tone # to hang-up.
Factory Setting: 3 minutes
Inbound Call Mode
The Inbound Call Mode determines how the E-35-IP handles incoming SIP calls.
One option is to generate a loud ring sound through the speaker. The E-35-IP
can also auto answer a SIP call to transmit a page, control the relay or
listen to transmit audio from the microphone. The last option is the silent
monitor mode, which allows callers to listen to the transmit audio from the
microphone. The “secure” options for auto answer require the callers to dial
the access code in order to transmit a page, activate the relay or activate
the optional RC-4A relays. Factory Setting: Auto Answer
Disabled – Inbound SIP calls are not allowed
Auto Answer – Inbound SIP calls are auto answered on the first ring. This can also be used for Silent Monitoring by changing the Speaker Mode to ‘OFF/Silent Monitor”, See page 16. For more security use the Auto Answer Secure Mode.
Auto Answer Secure – In the “Auto Answer – Secure” mode, the phone will automatically answer an incoming call on the first ring. The unit will then output 2 beeps but will not go into two-way voice mode. After the 2 beeps are heard, you will have 10 seconds to enter the pre-programmed 1 – 6 digit Access Code (see section 10 on page 14). When the correct code in entered, 2 beeps will be heard and the unit will enable the Two-Way Mode (mic and speaker audio). After the correct Access Code is entered, any of the “Remote Access Operation Commands” can be used (see Operation, section B on page 21). Note: If the wrong Access Code is entered or more than 10 seconds have elapsed, the phone will output 3 beeps and disconnect.
Ring: In the “Ring” mode the speaker phone will not automatically answer
an incoming call but will output a loud ring signal out of the speaker in a 2
seconds on, 4 seconds off ring pattern. There are four available ring
cadences.
Ring with AGC: In the “Ring with AGC” mode the speaker phone will not
automatically answer an incoming call but will output a loud ring signal out
of the speaker in a 2 seconds on, 4 seconds off ring pattern. The phone will
automatically increase or decrease the ring volume based on background ambient
noise. The call can then be answered by momentarily pressing the call button.
Ring Cadence
The Ring cadence can be programmed to one of 4 different cadences. Factory
Setting: Normal
Normal Ring (single ring, 2 seconds on 4 seconds off)
Double Ring (double ring, 1 second on 0.5 seconds off 1 second on 3.5
seconds off)
Short-Short-Long (triple ring, 0.5 seconds on 0.5 seconds off 0.5 seconds
on 0.5 seconds off 1 second on 3 seconds off)
Short-Long-Short (triple ring, 0.5 seconds on 0.5 seconds off 1 second on
0.5 seconds off 0.5 seconds on 3 seconds off).
Dial Next Number on Ring No Answer
If enabled and a ring-no-answer is detected, the E-35-IP will dial the next
programmed Speed Dial number after the programmed amount of rings. A momentary
press of the call button will dial the first programmed Speed Dial number.
Factory Setting: 7 (will dial after 7 rings)
Dial Next Number on Busy
If enabled and a busy is detected, the speaker phone will dial the next
programmed Speed Dial number. A momentary press of the call button will dial
the first programmed phone number. Factory Setting: Enabled
Send ID Number as
The I.D. number can be transmitted as RFC 2833 or as In-Band DTMF. Factory
Setting: RFC 2833
Call LED Mode
The “Call” LED can be programmed to one of four different modes. Factory
Setting: Entry Phone
OFF Mode: Useful for silent monitoring applications. In this mode the LED
will not light during normal operation. It will only light (blink) if it
cannot register with the programmed SIP server or while manually resetting all
network parameters to factory default.
Entry Phone Mode: The LED will remain ON in the idle state, turn off
while button is pressed, blink during dialing, light steady when the call is
answered, then turn OFF momentarily when the call is completed.
Emergency Phone Mode: The LED will remain OFF in the idle state, blink
during dialing, light steady when the call is connected, then turn OFF when
the call is completed.
Emergency Phone Outbound Only: On outbound calls, the LED will remain OFF
in the idle state, blink during dialing, light steady when the call is
connected, then turn OFF when the call is completed. On in-bound calls, the
LED will remain off. This is useful for silent monitoring on inbound calls.
“Call” LED Control
During outbound SIP calls the “CALL” LED can be programmed to light
automatically when the called party has answered or only light after the
called party has entered a touch tone “Q”. Factory Setting: Automatic
Mute Current / Next Alarm
A network failure alarm will be indicated by providing 3 beeps every 30
seconds. A network failure indicates the unit is not registered to the SIP
server or there is a communication failure with the gateway. The three beeps
can be muted by clicking on “Mute Current / Next Alarm”. The Status LED will
continue to flash to assist troubleshooting. The alarm beeps can also be
permanently disabled. See Permanent Alarm Mute.
Permanent Alarm Mute
Selecting “Alarm Tones Disabled” will mute all alarm tones indefinitely. To
re-enable alarm tones select “Alarm Tones Enabled”. Factory Setting: Alarm
Tones Enabled
IP Firmware
If new E-35-IP firmware is available, after opening the programming software a
pop window will come up asking you if you would like to update firmware. An
alternative method of updating can be done by clicking the IP firmware “Update
IP” button. You can then browse to the folder that contains the PIP file for
updating the unit’s IP firmware. This method is typically only used when
Viking Technical Support has sent you updated IP firmware
Unit Firmware
If new E-35-IP firmware is available, after opening the programming software a
pop up window will ask if you would like to update firmware. Another way to
update is accomplished by clicking the Unit firmware “Update Unit” button. You
can then browse to the folder that contains the HEX file for updating the
unit’s firmware. This method is typically only used when Viking Technical
Support has sent you updated firmware.
Import / Export
The Import / Export feature is useful for backing up all the E-35-IP’s
programming or for importing programming when installing multiple units with a
majority of the same programming.
Clear Unit Settings
Clicking on the “Clear Unit Settings” button in programming will reset all of
the Programming Features back to their factory default settings. Note: This
command will not change or reset your IP settings.
Clear IP Settings
Clicking on the “Clear IP Settings” will reset all of the IP settings back to
their factory default settings. This also clears paging Group settings and
Addresses. Note: This will not effect any speaker or paging settings.
Diagnostics
The Diagnostics section in the Viking IP Programming can be used to test the
functionality of the mic, speaker and the on-board relay. Note: This will not
work when relay mode is set to external or Alarm.
REX Input
The two green Request for Exit (REX) wires can be wired to a normally open,
momentary contact push button switch. With the relay in the Doorstrike Mode,
when the push button swith is pressed, the relay will be activated to open the
door.
Operation
“CALL” Button
When the “CALL” button is pressed, the E-35-IP phone dials a pre-programmed
telephone number. The Call Connected LED momentarily flashes during dialing.
In the event the line is busy or there is a ring-no-answer, the unit can be
programmed to call additional phone numbers.
The phone then cycles through up to 5 pre-programmed numbers until the call is answered. When the call is answered, the phones are factory programmed to automatically light the “Call” LED to show that handsfree communication to personnel is established. Once the “Call” LED is on, relay activation commands can be entered or the # key can be used to force the phone to hang-up.
After communication is established, enter the 1 or 2 digit relay activation command (factory set to “QQ”) to momentarily activate the entry phone (door strike) relay. If the (door strike) relay is activated, a buzz sound will be heard confirming the relay has been activated. If you require the relay to remain on continuously (ie: a truck delivery), enter Touch Tones “Q1” to continuously activate that relay. A double beep will indicate the (door strike) relay is latched on. When the visitor calls in again (ie: they are finished unloading the truck), enter Touch Tones “Q0” to deactivate the relay. A single beep will indicate the (door strike) relay is latched off. The E-35-IP color video camera operates completely independently of the E-35-IP phone board. With power supplied to the camera, it will continuously output a video signal.
Remote Access Operation Commands
The following commands can be entered after answering an inbound call from
the entry phone. The commands can also be entered on an outbound call to the
entry phone. After the entry phone auto answers the call, two beeps will be
heard. If the access code has been disabled, you can now enter the Remote
Access Operation Commands below. If an Access code has been programmed, enter
the Access code digits. With the correct code entered, two beeps will be heard
and you can now enter the Remote Access Operation Commands below.
Feature | Tone Tone Command | Description |
---|---|---|
Activate Relay | QQ or | Momentarily activate relay (1 or 2 digits, |
factory set to QQ).
Un-Latch Relay| Q 0| Un-latch (deactivate) the relay.
Latch Relay| Q 1| Latch (continuously activate) the relay.
Disconnect| #| Disconnects or forces the emergency phone to hang
up.
Send ID and Play Message| Q| Send I.D. number (if programmed) and plays
the announcement.
Note: Latching commands must be enabled (Q6) in programming
Troubleshooting
If the unit cannot register with the programmed SIP server, the LED will blink on and off every two seconds, and three error beeps will be heard every 30 seconds until communication is restored. This alerts a potential user of a problem with the device that will prevent an emergency phone call from being made.
You may silence the error beeps, per instance, by pressing and holding the CALL button for 5 seconds or by clicking the “Mute Alarm Until Next Failure” button in the Viking IP Programming Software (see section B on page 10). The error beeps automatically re-enable once the unit is registered, to alert of any new problems that arise.
Using a Viking Model RC-4A for Secure Remote Relay Control
The front panel of the E-35-IP is mounted using security Torx screws to help prevent intruders from removing the panel and accessing the on board door strike/gate control relays. For applications requiring additional security, a Viking model RC-4A remote relay controller can be used. The relay controller is mounted securely inside the building and connected to the same LAN as the E-35-IP. The on board door strike relays would not be used in this case as the E-35-IP will send an encrypted message to the RC-4A to activate its relays which control the door strikes/gates.
Up to 4 Viking VoIP Entry Phones can communicate with one RC-4A allowing you
to securely control four entrances.
When using an RC-4A for remote relay control the relays should be set to
“External” in the PC programming.
Note: If the Entry Phone loses communications with the RC-4A, the LED on the front panel of the E-35-IP will flash 3 times every 2 seconds indicating the communication error. If this error occurs, make sure the RC-4A is powered, has a network connection and has the correct IP address and security code of the E-35-IP displaying errors.
Related Products
Surface or Pedestal Mount Viking Products While Maintaining Weather and Vandal Resistance
The VE-3×5, VE-5×5, VE-6×7 and VE-5×10 add vandal and weather resistance, as
well as versatility to many Viking products. The VE-Series backboxes are
available in black fine texture powder painted steel or marine grade 316
stainless steel. The weather resistant boxes are designed to be surface
mounted to a wall, post, single gang box, or a VE-GNP gooseneck pedestal.
Note: The VE-3×5 is not compatible with the VE-GNP pedestals and is not
available in stainless steel.
The VE-GNP gooseneck pedestals are designed to be used with the VE-5×5, VE-6×7
and VE-5×10 back boxes and are ideal for drive up communications.
Note: The VE-3×5 is not compatible with the VE-GNP pedestals.
The VE-PNL’s are VE-Series backboxes with a blank aluminum panel. The user can
customize the clear-coated aluminum panel to mount an PRX-1 card reader, PRX2
keypad or switch. The kits come complete with box, gasket, panel and screws.
Model numbers that end with “SS” are stainless steel version.
Note: The use of magnets to mount the VE-Series enclosure to a metal
surface can affect the operation of the enclosed product.
Caution: Handsfree phones are not suitable for noisy applications (see
“Important” on page 2).
For more information on Viking Surface Mount Boxes and Pedestals, see DOD
424.
Add Panel Lighting to Your Viking VoIP Entry Phone
The VE-LIGHT kit adds bright LED illumination to any VoIP entry phone that is housed in a Viking VE-5×5, VE-6×7 or VE-5×10 enclosure.
The stainless steel bracket is easily mounted using existing holes and
hardware.
Two bright white LEDs are used as the light source, so there are no filaments
to break or bulbs to burn out.
A 12 VDC power adapter is included. Any power source between 12 and 24 volts,
AC or DC can be used to supply the VE-LIGHT with power.
For more information, see DOD 428.
VE-LIGHT shown above with Viking
E-30-IP and VE-5×5 (not included)
Warranty
IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, CONTACT VIKING TECHNICAL SUPPORT:715-386-8666
Our Technical Support Department is available for assistance Monday through Friday 8:00am to 5:00pm central time. So that we can give you better service, before you call please:
- Know the model number, the serial number and what software version you have (see serial label).
- Have the Product Manual in front of you.
- It is best if you are on site
RETURNING PRODUCT FOR REPAIR
The following procedure is for equipment that needs repair:
-
Customer must contact Viking’s Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number. The customer MUST have a complete description of the problem, with all pertinent information regarding the defect, such as options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc.
-
Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. The original product boxes are not designed for shipping – an overpack box is required to prevent damage in transit. Static sensitive equipment such as a circuit board should be in an anti-static bag, sandwiched between foam and individually boxed. All equipment should be wrapped to avoid packing material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D. or freight collect shipments cannot be accepted. Ship cartons prepaid to:
VIKING ELECTRONICS 1531 INDUSTRIAL STREET HUDSON, WI 54016 -
Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box.
-
RA number on carton: In large printing, write the RA number on the outside of each carton being returned.
RETURNING PRODUCT FOR EXCHANGE
The following procedure is for equipment that has failed out-of-box (within 10 days of purchase):
- Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to step through recommended tests for diagnosis.
- If the Technical Support Product Specialist determines that the equipment is defective based on the customer’s input and troubleshooting, a Return Authorization (RA) number will be issued. This number is valid for fourteen (14) calendar days from the date of issue.
- After obtaining the RA number, return the approved equipment to your distributor. Please reference the RA number on the paperwork being shipped back with the unit(s), and also the outside of the shipping box. The original product boxes are not designed for shipping – an over pack box is required to prevent damage in transit. Once your distributor receives the package, they will replace the product over the counter at no charge. The distributor will then return the product to Viking using the same RA number.
- The distributor will NOT exchange this product without first obtaining the RA number from you. If you haven’t followed the steps listed in 1, 2 and 3, be aware that you will have to pay a restocking charge.
TWO YEAR LIMITED WARRANTY
Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of two years from the date of purchase from any authorized Viking distributor. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact Viking’s Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number.
This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence or any damage caused by use of the product by the purchaser or others. This warranty does not cover non-EWP products that have been exposed to wet or corrosive environments. This warranty does not cover stainless steel surfaces that have not been properly maintained.
NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER THAN AS DESCRIBED ABOVE AND DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
EXCLUSION OF CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO PURCHASER, OR ANY OTHER PARTY, FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAMAGES ARISING OUT OF OR RELATED TO THE SALE OR USE OF THE PRODUCT SOLD HEREUNDER.
EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR ANY OTHER LEGAL THEORY, ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT, OR AT VIKING’S OPTION, REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY OF VIKING SHALL BE SO LIMITED.
IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF WARRANTIES, EXCLUSION OF CONSEQUENTIAL DAMAGES, AND EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY, ARE SEVER ABLE FROM ANY OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH.
If trouble is experienced with the E-35-IP phone, for repair or warranty
information, please contact:
Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI
54016715-386-8666
WHEN PROGRAMMING EMERGENCY NUMBERS AND (OR) MAKING TEST CALLS TO EMERGENCY
NUMBERS:
Remain on the line and briefly explain to the dispatcher the reason for the
call. Perform such tests in off-peak hours, such as early morning or late
evenings.
PART 15 LIMITATIONS
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
CANADA
This class A digital apparatus complies with Canadian ICES-003.
Product Support: 715-386-8666
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.
References
- Axis Communications - Leader in network cameras and other IP networking solutions | Axis Communications
- Northern
- Security & Communication Systems - Access Control | Viking Electronics, Inc
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>