T700TL Heavy Duty 24V System Actuator
Installation Guide
APC-T700TL & T800TL
APC-T750TL & T850TL
Heavy Duty 24V System
Actuator Installation Manual
Attention Installer
The manual should be read cover to cover at least once prior to beginning
installation
Specifications
The above specifications are based on perfect free flowing installations on
non-cladded or covered gate using ball bearing hinges.
*Larger sized gates may require an electric lock
Preliminary Checks
To ensure safety and an efficient automation make sure the following requirements are met:
- The gate structure must be suitable for automation.
- Make sure that the gate leafs move properly and uniformly without any irregular friction during their entire travel.
- The gates hinges must be in good condition with no bitting, no rust and must be well greased.
- The gates should be able to be freely opened and closed before installing the gates automation system.
- It is strongly suggested to have a gate stop installed for the closed position.
Important Safety Information
Installer and owners should observe the following:
- Make sure that there is sufficient space for the gate(s) to swing open fully to the desired opening angle.
- The control Panel Box must be installed in the area within 9 meters maximum cable distance from motor and cannot be damaged.
- Do not change with parts or components not supplied by the manufacturer, this includes sensors, buttons, solar panels, transformers and any component not listed in the compatibility list.
- Make sure all wiring works are correct and in good condition before connecting the battery, solar panel or transformer to the control panel.
- Turn off the power and disconnect the battery when doing any maintenance.
- Ensure the control panel box is free from water leakage to avoid short circuiting of the control panel.
- Do not supply mains power directly to the motor, control box or any accessories.
- Do not install the operating system if in doubt. Contact the manufacturer.
- Do not cross the gate while it is operating, Safety sensors are only to prevent accidents or injuries.
- Keep the remote controls in safe place and away from children.
Before beginning installation the manual should be read thoroughly concerning all aspects of the installation including all precautions and safety information.
Proper steps should be taken to ensure efficient and safe installation for
vehicles, property and persons within the operators working radius.
The system is fitted with an over current sensing feature to assist in
preventing damages, injuries and death. All precautions must be taken by the
installer that adjustments are set correct based on the gates weight, height
and length. The system sensitivity should be set to allow consistent operation
of the gates under normal operating conditions. This does not include
operating against wind. The system may not detect (Over current sense) against
light loads such as small object, young children and animals. It is the
operators duty to ensure that the area is clear prior to operation.
Photo sensors or Reflective sensors should always be installed to assist in
accident or death prevention. Rubber edging should be installed onto the gates
to assist in dampening any accidents or damages.
You agree to install this product following any and all safety requirements
listed in this manual or required under local, state or national regulations.
APC Australia, its distributors, stockist or sellers are not liable for any
direct, indirect, incidental, special or consequentional damages or loss of
profit wether based in contract or any other legal theory during the course
of warranty or afterwards. If you do not feel capable of properly installing
the operator based on the above information or otherwise do not proceed.
Tools Required
Motor Stroke & Bracket Dimensions
UNDER NO CIRCUMSTANCES SHOULD THE EXPANDED STROKE OF THE MOTOR BE USED AS A LIMIT
Clutch Override
In case of an emergency or requirements during installation the gate can be moved open and close by hand operation if the clutch is disengaged. To disengage the clutch follow the procedure below.
- Slide forward the top cover.
- Insert the key and turn to the unlock symbol.
- Turn the knob by 180° toward the open writing.
Ensure that the knob is always straight prior to closing the top cover to prevent damage or breakage
Limit Switch Wiring (Pre-Wired)
Post Bracket Manipulation
Post installation methods
Small Square Post
Welding equipment accessible
Tek Screw Fixing (Not Included)
Using 200x100mm Plate (Not Included)
Small Square Post
Welding equipment not accessible
Tek Screw Fixing (Not Included)
Using 200x100mm Plate (Not Included)
Round Post
Cut to allow square fixing
Coach Bolt Fixing (Not Included)
200x100mm Plate may be required (Not Included)
Optional APC-FGB2532 Farm Gate Bracket System
Post Adapter Bracket
Suits Round & Square Posts from 70mm and up to 300mm
Gate Stop Installation
Before beginning the installation of the gate motors a physical gate stop must
be installed at the closed position.
For Single gate systems the gate stop can be installed in two different
methods.
- On the driveway itself at the furthest point from the hinge as illustrated in the diagram below (Fig 1).
- On the post that the gate will close too (Fig 2).
For Double gate systems the gate stop must be installed in the center of the driveway stopping both gates (Fig 3).
When installing on the driveway itself it is recommended to use a rubber floor stop to prevent damage to vehicle entering and exiting.
When installing on the post for single gate installations a 90° angle can be used with a rubber padding to dampen or soften the close and prevent damage to the gate.
UNDER NO CIRCUMSTANCES SHOULD THE EXPANDED STROKE OF THE MOTOR BE USED AS A LIMIT
Pull to Open Installation
-
Install the center of the post bracket inline with the center of your gates horizontal rail using the supplied geometry above. See post bracket manipulation and installation on page 3.
-
a) Retract the actuator to 120mm from the end of stroke (120mm of stainless piston showing).
b) Open the gate to the desired open angle.
c) Install the gate bracket onto the actuator.
d) Install the actuator onto the post bracket which was installed in the previous step.
-
a) Use a bubble level to ensure the actuator is straight then mark the two gate bracket fixing holes on the gates horizontal rail.
b) Disconnect the gate bracket from the actuator. -
Install the gate bracket onto the gate then re-install the actuator to the gate bracket.
Actuator installation complete Repeat steps 1 to 4 for second gate if applicable
Adjusting Limits for Pull to Open
- Set the actuator into manual over ride (Page 2)
- Open the Gate manually
- Slide the open limit (A) towards the internal nut until contact is made, a click will be heard from the micro switch.
- Close the gate manually
- Slide the close limit (B) towards the internal nut until contact is made, a click will be heard from the micro switch.
Minor adjustments can be made later after the setup of the control board.
Logico 24 Wiring
Pull-To-Open
Motor will be pulling the gate towards it for OPENING.
Gates (Left and Right) are based on observation of the gates from the same
side the motors will be installed on.
CBSW 24 Wiring
APC WARRANTY
APC warrants the original purchasers or the APC gate(s) opening system for a
period of twelve months from the date of purchase (not installation), the
product shall be free of defects in materials and workmanship under normal
use.
During the warranty period, APC shall, as its option, repair or replace any
defective product upon return of the product to its factory, at no charge for
labour and materials.
Any replacement and/or repaired parts are warranted for the remainder of the
original warranty, The original owner must promptly notify APC in writing that
there is defect in material or workmanship, such written notice must be
received in all events prior to expiration of the warranty.
International Warranty
APC shall not be responsible for any freight fees, taxes or customs fees.
Warranty Procedure
To obtain service under this warranty, AND AFTER CONTACTING APC, please return
the item(s) in question to the point of purchase.
All authorized distributors and dealers have a warranty program, anyone
returning goods to APC must first obtain an authorization number. APC will not
accept any shipment for which prior authorization has not been used.
Conditions to Void Warranty
This warranty applies only to defects in pairs and workmanship relating to
normal use. It does not cover:
- Damage incurred in shipping or handling
- Damage caused by disaster such as fire, flood, wind, earthquake or lightning
- D amage due to causes beyond the control of APC such as excessive voltage, mechanical shock or water damage
- Damage caused by unauthorized attachment, alterations, modifications, or foreign objects.
- Damage caused by peripherals (unless such peripherals were supplied by APC)
- Defects caused by failure to provide a suitable installation environment for the products
- Damage caused by usage of the products for purpose other than those for which it was designed.
- Damage from improper maintenance
- Damage arising out of any other abuse, mishandling, and improper application of the products.
Under no circumstances shall APC be liable for any special, incidental, or consequential damages based upon breach of warranty, breach of contract, negligence, strict liability, or any other legal theory. Such damages include, loss of profits, loss of the product or any associated equipment, cost of capital, cost of substitute or replacement equipment, facilities or services, down time, purchaser’s time, the claims of third parties, including customers, and injury to property.
Disclaimer of Warranties
This warranty contains the entire warranty and shall be in lieu of any and all
other warranties, whether expressed or implied (including all implied
warranties of merchantability or fitness for a particular purpose). And of
all other obligations or purporting to act on its behalf to modify or to
change this warranty, nor to assume for it any other warranty or liability
concerning this product.
Out of Warranty Repairs
APC will at its option repair or replace out-of-warranty products which are
returned to its factory according to the following conditions. Anyone
returning goods to APC must first obtain an authorization number.
APC will not accept any shipment whatsoever for which prior authorization has
not been obtained. Products which APC determines to be repairable will be
repaired and returned. A set fee which APC has been predetermined and which
may be revised from time to time will be charged for each unit repaired.
Products which APC determines not repairable will be replaced by the nearest
equivalent product available at that time. The current market price for the
replacement product will be charged for each replacement unit.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>