ecler VEO-XTI1CG2 H.265 Full HD Over IP Video Extenders User Manual
- June 4, 2024
- ecler
Table of Contents
- VEO-XTI1CG2 H.265 Full HD Over IP Video Extenders
- Specifications
- Product Usage Instructions
- Precautions
- Package Contents
- Installation and Connection
- Start-up and Operation
- Panel Functions
- Technical Data
- User Manual
- Q: Can I connect multiple devices to the video extenders?
- Q: How do I troubleshoot connectivity issues with the video
VEO-XTI1CG2 H.265 Full HD Over IP Video Extenders
Specifications
-
Model: VEO-XTI1CG2 / VEO-XRI1CG2
-
Product Type: Video Distribution over IP H.265 Full HD Video
Extenders -
Resolution: Full HD
-
Video Compression: H.265
Product Usage Instructions
Precautions
Before using the product, please take note of the following
precautions:
-
Read and keep the user manual for reference.
-
Avoid using the device near water.
-
Clean the device only with a dry cloth.
-
Ensure proper ventilation around the device.
-
Avoid exposure to rain or moisture to prevent fire or shock
hazards. -
Do not block ventilation openings.
-
Follow all safety warnings and instructions provided.
Package Contents
The package includes:
- VEO-XTI1CG2 Video Extender
- VEO-XRI1CG2 Video Extender
Installation and Connection
Follow these steps to install and connect the video
extenders:
-
Refer to the user manual for detailed installation
instructions. -
Connect the video extenders to the respective devices using
appropriate cables. -
Ensure a stable power source for both extenders.
-
Place the extenders in well-ventilated areas away from heat
sources.
Start-up and Operation
To start and operate the video extenders:
- Power on both extenders using the provided power source.
- Check the connection status and adjust settings as needed.
- Refer to the user manual for further operational details.
Panel Functions
The panel functions include:
- Power Button
- Input/Output Ports
- Status Indicators
Technical Data
The technical specifications of the video extenders:
-
Main Features: Full HD Video Distribution over IP, H.265
Compression -
Model Number: VEO-XTI1CG2 / VEO-XRI1CG2
User Manual
For detailed instructions on using the product, refer to the
user manual provided (Model: 50-0430-0106).
FAQ
Q: Can I connect multiple devices to the video extenders?
A: Yes, you can connect multiple devices to the video extenders
as long as they are within the supported specifications and network
capacity.
Q: How do I troubleshoot connectivity issues with the video
extenders?
A: If you experience connectivity issues, ensure that all
connections are secure, power cycle the devices, and check network
settings. Refer to the user manual for detailed troubleshooting
steps.
PRECAUTIONS
VEO-XTI1CG2 / VEO-XRI1CG2
VIDEO DISTRIBUTION OVER IP H.265 Full HD over IP Video Extenders
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
PANEL
FUNCTIONS
TECHNICAL
DATA
USER MANUAL
50-0430-0106
VEO-XTI1CG2 – VEO-XRI1CG2
EN
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
TABLE OF CONTENTS
1. PRECAUTIONS …………………………………………………………………………………………………………3 1.1 Important
Remark…………………………………………………………………………………………………….. 3 1.2 Important Safety
Instructions …………………………………………………………………………………. 4 1.3
Cleaning…………………………………………………………………………………………………………………….. 4
2. PACKAGE CONTENTS …………………………………………………………………………………………….5 2.1 VEO-XTI1CG2
………………………………………………………………………………………………………….. 5 2.2 VEO-XRI1CG2
………………………………………………………………………………………………………….. 5
3. DESCRIPTION and FEATURES………………………………………………………………………………..6 3.1 Main
Features …………………………………………………………………………………………………………… 6
4. INSTALL & CONNECT………………………………………………………………………………………………7 4.1 Network
requirements and configuration ……………………………………………………………… 7 4.1.1 Setting the IP
address……………………………………………………………………………………………….7 4.1.2 Video distribution Quick
Start ………………………………………………………………………………….8 4.1.3 Unicast mode
……………………………………………………………………………………………………………..8 4.1.4 Multicast mode
…………………………………………………………………………………………………………..9
5. START-UP and OPERATION ……………………………………………………………………………….. 10 5.1
Configuration using Web Interface……………………………………………………………………….10 5.1.1
Information ……………………………………………………………………………………………………………… 10 5.1.2 Video Settings
………………………………………………………………………………………………………… 11 5.1.3
Led……………………………………………………………………………………………………………………………. 15 5.1.4
Settings……………………………………………………………………………………………………………………. 16 5.1.5
Update……………………………………………………………………………………………………………………… 18 5.1.6 Log Out
……………………………………………………………………………………………………………………. 19 5.2 Remote Controlling
…………………………………………………………………………………………………19 5.2.1
RS-232…………………………………………………………………………………………………………………….. 19 5.2.2 Advanced Network
Management ………………………………………………………………………… 22
6. PANEL FUNCTIONS ……………………………………………………………………………………………… 23 6.1 VEO-XTI1CG2
(TX, transmitter) ……………………………………………………………………………23 6.1.1 Front
Panel………………………………………………………………………………………………………………. 23 6.1.2 Rear
Panel……………………………………………………………………………………………………………….. 24 6.2 VEO-XRI1CG2 (RX,
receiver)…………………………………………………………………………………25 6.2.1 Front
Panel………………………………………………………………………………………………………………. 25 6.2.2 Rear
Panel……………………………………………………………………………………………………………….. 26 6.3 Additional
Functionalities of CH Select / buttons for both: VEO-XTI1CG2 and VEO-XRI1CG2
…………………………………………………………………………………………………………27
7. TECHNICAL DATA ……………………………………………………………………………………………….. 30 7.1 Technical
Specifications …………………………………………………………………………………………30 7.2 Mechanical Diagram
……………………………………………………………………………………………….32 7.2.1 VEO-XTI1CG2
………………………………………………………………………………………………………… 32 7.2.2 VEO-XRI1CG2
………………………………………………………………………………………………………… 32
2
PANEL
FUNCTIONS
TECHNICAL
DATA
1. PRECAUTIONS
1.1 IMPORTANT REMARK
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
PANEL
FUNCTIONS
TECHNICAL
DATA
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
WARNING (If applicable): The terminals marked with symbol of ” ” may be of
sufficient
magnitude to constitute a risk of electric shock. The external wiring
connected to the terminals requires installation by an instructed person or
the use of ready-made leads or cords.
WARNING: To prevent fire or shock hazard, do not expose this equipment to rain
or
moisture.
WARNING: A device with Class I construction shall be connected to a mains
socket-outlet
with a protective earthing connection.
WARNING: This product must not be discarded, under any circumstance, as
unsorted urban waste. Take to the nearest electrical and electronic waste
treatment centre.
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
3
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
1.2 IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this device near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers,
stoves, or other device (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding type plug.
A polarized plug has two blades with one wider than the other. A grounding
type plug has two blades and a third grounding prong. The wide blade or the
third prong are provided for your safety. If the provided plug does not fit
into your outlet, consult an electrician for replacement of the obsolete
outlet.
10. Protect the power cord from being walked on or pinched particularly at
the plugs, convenience receptacles, and at the point where they exit from the
device.
11. Only use attachments/accessories specified by the manufacturer.
12. Unplug the device during lightening sorts or when unused for long periods
of time.
13. Refer all servicing to qualified personnel. Servicing is required when
the device has been damaged in any way, such as power supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the device, the
device has been exposed to rain or moisture, does not operate normally, or has
been dropped.
14. Disconnecting from mains: When switching off the POWER switch, all the
functions and light indicators of the unit will be stopped, but fully
disconnecting the device from mains is done by unplugging the power cable from
the mains input socket. For this reason, it always shall remain easily
accessible.
15. Equipment is connected to a socketoutlet with earthing connection by
means of a power cord.
16. The marking information is located at the bottom of the unit.
17. The device shall not be exposed to dripping or splashing and that no
objects filled with liquids, such as vases, shall be placed on device.
INSTALL &
CONNECT
START-UP &
OPERATION
PANEL
FUNCTIONS
TECHNICAL
DATA
1.3 CLEANING Clean the unit with a soft, dry clean cloth or slightly wet with
water and neutral liquid soap only, then dry it with a clean cloth. Be careful
that water never gets into the unit through any hole. Never use alcohol,
benzine, solvents or abrasive substances to clean this unit.
NEEC AUDIO BARCELONA, S.L. accepts no liability for any damage that may be
caused to people, animal, or objects due to failure to comply with the
warnings above.
4
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
Thank you for choosing our device Ecler VEO-XTI1CG2 and VEO-XRI1CG2! We
appreciate your trust.
It is VERY IMPORTANT to carefully read this manual and to fully understand its
contents before any connection in order to maximize your use and get the best
performance from this equipment. To ensure optimal operation of this device,
we strongly recommend that its maintenance be carried out by our authorised
Technical Services. All ECLER products are covered by warranty, please refer
to www.ecler.com or the warranty card included with this product for the
period of validity and conditions.
2. PACKAGE CONTENTS
2.1 VEO-XTI1CG2 · 1 x Transmitter. · 2 x 3-pin Euroblock connectors. · 4 x
Screws. · 2 x Detachable mounting ear. · 1 x 12V DC power adapter with
international blades. · Getting Started Guide. · Warranty card.
2.2 VEO-XRI1CG2 · 1 x Receiver. · 2 x 3-pin Euroblock connectors. · 4 x
Screws. · 2 x Detachable mounting ear. · 1 x 12V DC power adapter with
international blades. · Getting Started Guide. · Warranty card.
5
PANEL
FUNCTIONS
TECHNICAL
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
3. DESCRIPTION and FEATURES
VEO-XTI1CG2 transmitter and VEO-XRI1CG2 receiver are a H.265 / H.264 over IP
set of extenders that allow for HDMI distribution over 1Gb Ethernet networks
with up to 1080p@60Hz video support. These devices represent a professional
high-quality compression and low bandwidth solution aimed for point-to-point,
as well as multipoint-tomultipoint scenarios over a single 100m Cat5e/6/7
cable. VEO-XTI1CG2 and VEO-XRI1CG2 are widely suitable for various
applications which also require PoE, audio management, video wall compositing
or remote control, such as educational, commercial, or corporate
installations, where flexible and scalable AV systems are in need.
Furthermore, this encoder and decoder can be paired with VEO-XCTRLG2 control
module for and expanded management experience with in-built WEB configuration
interface.
3.1 MAIN FEATURES · HDMI 1.4 with video resolution up to 1920x1200p@60Hz
4:4:4. · Signal transmission distance up to 100m over Cat5e/6/7 cable. ·
Support for unicast over 1Gb unmanaged networks and multicast signal extension
over 1Gb managed networks. · Support for video wall compositing up to 9 x 9
setups. · Support for audio embedding and extraction. · Support for mainstream
and sub stream encoding modes. · Support for pass through and RS-232, TCP/IP,
Web GUI management using VEOXCTRLG2 controller module. · HDCP 1.4 compliant. ·
Support for PoE function. · Local 12V DC power supply.
6
PANEL
FUNCTIONS
TECHNICAL
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
4. INSTALL & CONNECT
4.1 NETWORK REQUIREMENTS AND CONFIGURATION VEO-XTI1CG2 and VEO-XRI1CG2 are not
limited to certain brands of network hardware, but the network must support
the following network features:
· Layer 3 managed network switch. · IGMP snooping support.
To prevent malfunctioning, interference or drop in signal performance due to
other network products bandwidth requirements or network design. It is highly
recommended to check with the chosen network IT staff how to properly set the
Multicast products connected to the local network switch.
4.1.1 SETTING THE IP ADDRESS The default IP address is “auto IP” in the range
169.254.10.x for the transmitter and 169.254.20.x for the receivers. It can
also be dynamically assigned by the VEO-XCTRLG2 controller in case it is
present in the network. For further details please refer to VEOXCTRLG2
controller module user manual.
· It’s possible to check the assigned IP address from a transmitter or
receiver pressing and holding the (UP button) on the front panel. For further
details, refer to Additional functionalities of CH select / buttons for both:
VEO-XTI1CG2 & VEOXRI1CG2 chapter.
· The IP address can be changed using the embedded web page of transmitter and
receiver. Both the network configuration of PC and VEO devices must be in the
same network domain in order to be able to access its web settings page
through an internet browser. For further details, refer to Configuration using
Web interface chapter.
When static IP addresses are required, the IP address of each device needs to
be set manually.
7
PANEL
FUNCTIONS
TECHNICAL
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
4.1.2 VIDEO DISTRIBUTION QUICK START To begin a video transmission, a matching
between an encoder and a decoder is required. Each VEO-XTI1CG2 transmitter can
stream a video signal over the network using an ID channel number that must be
unique in the same network. Each ID channel from 0 to 762 identifies a
multicast address and every VEO-XRI1CG2 receiver can select one of these
channels in order to receive an AV stream. The ID channel for transmitters is
usually set once during the setting up of the system while the receivers ID
usually are the ones that are modified in order to show different content on
the displays. The destination receiver ID must be set in the same channel as
the transmitter broadcasting the desired source audio and video content. The
ID channel can be selected in four different ways:
· By front panel buttons of the devices (VEO-XTI1CG2 has the ID assignement
blocked by default and should be adjusted entering CFN mode, long pressing
DOWN button. See chapter Additional functionalities of CH select / buttons for
both: VEOXTI1CG2 AND VEO-XRI1CG2).
· By using the Web Page configuration. · Via RS-232. · Via TCP using the VEO-
XCTRLG2 controller.
4.1.3 UNICAST MODE When VEO-XTI1CG2 and VEO-XRI1CG2 devices are connected as a
simple point to point extension, no additional configuration is needed.
1. Connect the source device to the VEO-XTI1CG2 transmitter to the HDMI port.
2. Connect Audio IN/OUT to a sound device and select the required audio mode.
3. Connect the remote endpoint to the VEO-XRI1CG2 receiver’s HDMI port output.
4. Connect the transmitter and receiver with Cat5e/6/7 cable. 5. Connect an
RS-232 cable from the automation system to the transmitter port. 6. Connect
RS-232 cable from the receiver to the port of the device to control. 7. Power
VEO-XTI1CG2 transmitter and VEO-XRI1CG2 receiver with the included
power adapter.
Set the same ID for both devices. 8
PANEL
FUNCTIONS
TECHNICAL
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
4.1.4 MULTICAST MODE When VEO-XTI1CG2 and VEO-XRI1CG2 devices are connected in
a point to multipoint or multipoint to multipoint topology, every transmitter
and receiver should have a unique IP address. When possible, it is recommended
to create an independent IP video network using managed network switches. Use
of gigabit switches with an IGMP support will create the most appropriate
scenario.
1. Set the IP address for each transmitter and receiver. 2. Connect the
source devices to the HDMI ports of the VEO-XTI1CG2 transmitters. 3. Connect
the HDMI endpoints to the HDMI ports of the VEO-XRI1CG2 receivers. 4. Connect
Audio IN/OUT to a sound device and select the required audio mode. 5. Connect
an RS-232 cable from the automation system to the transmitters ports. 6.
Connect RS-232 cables from the receivers to the ports of the devices to
control. 7. Connect all VEO devices to the network switch using Cat.
5e/6/7cables. 8. Power VEO-XTI1CG2 transmitter and VEO-XRI1CG2 receiver with
the included
power adapter and power the switch. In case the switch supports PoE (Power
over Ethernet), it will not be necessary to power the VEO devices locally. 9.
Choose the desired ID channel for each of the VEO devices in order to
establish the required video transmission flows.
9
PANEL
FUNCTIONS
TECHNICAL
DATA
5. START-UP and OPERATION
5.1 CONFIGURATION USING WEB INTERFACE VEO-XTI1CG2 and VEO-XRI1CG2 devices can
be configured through their own built-in web interface by simply typing the IP
address of the chosen device into a web browser. Refer to chapter Setting the
IP address for further details. The default credentials to log in are:
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
· User name: · Password:
admin admin
Once the login credentials have been filled out correctly, the menus of the
web settings page will let the user manage and operate different aspects and
functionalities concerning encoder and decoder operation, as explained in the
next chapters.
5.1.1 INFORMATION
PANEL
FUNCTIONS
TECHNICAL
DATA
The Status page provides basic information about VEO-XTI1CG2 and VEO-XRI1CG2
such as:
· Firmware Version · IP Address · Subnet Mask · Gateway · MAC Address
10
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
5.1.2 VIDEO SETTINGS 5.1.2.1 VEO-XTI1CG2 VIDEO SETTINGS The video settings
page will enable the user to configure the following parameters for VEO-
XTI1CG2.
1. Main Stream · Video Encoding Format: the user can select H.265 and H.264
video codec for the mainstream. · Audio Encoding Format: the user can select
PCM or AAC audio for the mainstream. · Resolution: it shows the HORITZONAL and
VERTICAL resolution for the mainstream. This setting follows the input
resolution of the video source. · Bitrate: the user can adjust the video
quality choosing the maximum transmitted data for the mainstream.
2. Sub Stream · Video Encoding Format: the user can select H.265 and H.264
video codec for the sub stream. · Resolution: the user can set the HORITZONAL
and VERTICAL resolution for the sub stream. · Bitrate: the user can adjust the
video quality choosing the maximum transmitted data for the sub stream.
11
PANEL
FUNCTIONS
TECHNICAL
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
3. Audio Selection This parameter lets the user choose the Audio mode (ANALOGUE / HDMI) for the VEOXTI1CG2 transmitter’s AUDIO IN. · ANALOGUE: audio signal coming from the external analogue source connected to AUDIO IN is embedded in the HDMI signal flow and outputted through AUDIO OUT connector in VEO-XRI1CG2. · HDMI: embedded audio in the HDMI signal flow is outputted through AUDIO OUT connector both in VEO-XTI1CG2 and VEO-XRI1CG2 connectors.
4. EDID Setting
This parameter selects the EDID setting for the VEO-XTI1CG2 transmitter. For
further details, refer to Additional functionalities of CH select / buttons
for both: VEOXTI1CG2 & VEO-XRI1CG2 chapter to check the available options.
EDID ID
EDID Description
00
Video: HDMI 1080p@60Hz / Audio: Stereo PCM
01
Video: HDMI 720p@60Hz / Audio: Stereo PCM
02
Video: DVI 1024p@60Hz
03
Video: DVI 1080p@60Hz
04
Video: DVI 1200p@60Hz
05
Video: HDMI 1200p@60Hz / Audio: Stereo PCM
06
Copy from VEO-XRI1CG2 HDMI output
07
USER 1
08
USER 2
User EDID 1 and User EDID 2 can be uploaded in SELECT USER EDID 1 FILE and SELECT USER EDID2 FILE. (This file can be downloaded from the Download EDID of the Decoder Video page).
INSTALL &
CONNECT
START-UP &
OPERATION
PANEL
FUNCTIONS
TECHNICAL
DATA
12
5.1.2.2 VEO-XRI1CG2: VIDEO SETTINGS
The video settings page will enable the user to configure the following
parameters for VEO-XRI1CG2.
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
PANEL
FUNCTIONS
TECHNICAL
DATA
1. Transmission
This parameter selects UNICAST or MULTICAST as the chosen network transmission protocol.
2. Scaler Setting
This parameter sets the output resolution scaling up on the HDMI OUT of the VEOXRI1CG2 receiver.
Resolution ID 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19
Resolution Description Pass-through 1080p@60Hz 1080p@50Hz 1080p@30Hz 1080p@25Hz 1080p@24Hz 720p@60Hz 720p@50Hz 576@50Hz 480@60Hz 640×480@60Hz 800×600@60Hz 1024×768@60Hz 1280×800@60Hz 1280×1024@60Hz 1366×768@60Hz 1440×900@60Hz 1600×1200@60Hz 1680×1050@60Hz 1920×1200@60Hz
13
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
3. Download EDID This parameter enables the user to download the EDID binary
file of the endpoint device connected to the VEO-XRI1CG2 receiver. The EDID
file can be used as the User EDID file to be uploaded to the VEO-XTI1CG2.
4. Video Timeout Setting This parameter sets the timeout time to turn off the
HDMI OUT output when no video signal is detected. Selecting “0” disables this
function.
5. OSD Color Setting This section lets the user adjust the colour parameter
of the data shown in the screen.
6. Picture Setting This section lets the user adjust video parameters
(Brightness, Contrast, Hue and Saturation) to better fit the output display
and deliver the most appropriate video experience possible.
14
PANEL
FUNCTIONS
TECHNICAL
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
5.1.3 LED This page allows the user to select the led status for both, VEO-
XTI1CG2 and VEOXRI1CG2.
1. Front Panel Power LED Flash: This parameter selects the status of the
Front Panel LED as follows: · ON: The LED remains permanently lighted. · OFF:
After 90s the LED is switched off automatically.
2. Power LED Flashing: · ON: The Power LED remains permanently blinking. ·
OFF: The Power LED stays on without blinking. · ON 90s: The Power LED blinks
for 90s and then stops.
15
PANEL
FUNCTIONS
TECHNICAL
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
5.1.4 SETTINGS 5.1.4.1 VEO-XTI1CG2 SETTINGS This page allows the user to
modify the network configuration of the VEO-XTI1CG2 device.
1. Network · IP address · Subnet Mask · Gateway · HTTP Web Port · The Network
Settings can be set only when the MODE button is set to Static. · After any
changes to the network settings, username or password, the user will have to
log in the Web GUI again with the new settings to resume working.
2. Security This parameter turns on or off HTTPS security protocol.
3. Setting Local ID: this parameter sets the ID Channel for the VEO-XTI1CG2
transmitter from the 1-762 available profiles. 16
PANEL
FUNCTIONS
TECHNICAL
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
4. Button Fast Setting Local ID Fast Setting: ON/OFF – This parameter enables
the front buttons of the device so that the user can physically change the ID
from the front panel of the device.
5. Username This parameter lets the user modify the username assigned to the
device.
6. Login This section allows the user to change the current password to
access the web settings page.
5.1.4.2 VEO-XRI1CG2 SETTINGS This page allows the user to modify the network
configuration of the VEO-XRI1CG2device.
1. Network · IP address · Subnet Mask · Gateway · HTTP Web Port · The Network
Settings can be set only when the MODE button is set to Static. · After any
changes to the network settings, username or password, the user will have to
log in the Web GUI again with the new settings to resume working. 17
PANEL
FUNCTIONS
TECHNICAL
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
2. Security This parameter turns on or off HTTPS security protocol.
3. Setting · Local ID: this parameter sets the ID Channel for the VEO-XRI1CG2
receiver from the 1-762 available profiles. · Max Channel ID: this parameter
sets the range of ID Channel that will be available in the VEO-XRI1CG2 devices
included in a given installation. Selecting “0” will enable the complete range
of 0-762 channels. · Source Selection ID: this parameter sets the transmission
channel for the VEOXRI1CG2 receiver from the 0-762 available channels. When
both a transmitter and a receiver are tuned in the same channel, video will
show from the VEOXRI1CG2 HDMI output.
4. Username This parameter lets the user modify the username assigned to the
device.
5. Login This section allows the user to change the current password to
access the web settings page.
5.1.5 UPDATE 5.1.5.1 VEO-XTI1CG2 UPDATE
1. Firmware Update: · Browse: This will import the upgrade file. · Update:
This will start the upgrade process. When the progress bar reaches 100%, the
upgrade is successful, and the device will restart.
2. Factory Reset: This will reset the device to the factory default settings.
3. Reboot: This will reboot the device.
18
PANEL
FUNCTIONS
TECHNICAL
DATA
5.1.5.2 VEO-XRI1CG2 UPDATE
PRECAUTIONS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
PACKAGE CONTENTS
PANEL
FUNCTIONS
1. Firmware Update: · Browse: This will import the upgrade file. · Update:
This will start the upgrade process. When the progress bar reaches 100%, the
upgrade is successful, and the device will restart.
2. IMG Update: · Browse: This will import the splash screen file. · Update:
This will start the update the splash screen image that will show on the
receiver when the input source is disconnected.
3. Factory Reset: This will reset the device to the factory default settings.
4. Reboot: This will reboot the device.
5.1.6 LOG OUT
Selecting Log Out automatically.
will exit the Web GUI and skip to the login interface
5.2 REMOTE CONTROLLING
5.2.1 RS-232 To match the ID from a transmitter to a receiver, connect the
RS-232 port of VEO-XTI1CG2 and VEO-XRI1CG2 to a PC serial interface or a
RS-232 control system.
5.2.1.1 RS-232 COMMUNICATION PROTOCOL The serial parameters for a correct transmission are: Baud rate 115200 Data bits 8 Stop bits 1 Parity None
Flow control None
TECHNICAL
DATA
19
5.2.1.2 COMMAND LIST
It is important to add carriage return (
PRECAUTIONS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
PACKAGE CONTENTS
PANEL
FUNCTIONS
Command Code Set RX ID xxx
connect to TX ID yyy
Set RX ID xxx to ID yyy
Set RX ID xxx to SCALE yyy
Set RX ID xxx to max TX ID
number allows to connect
Set TX ID xxx to ID yyy
Description
Command Return
Parameter Description
Set OUTPUT xxx xxx: RX ID number, ranging from 1 to 762 !OUT xxx FR yyyrn From INPUT:yyy yyy: TX ID number, ranging from 1 to 762
!OUT xxx ID yyyrn !OUT xxx SL yyyrn
!OUT xxx PM yyyrn !IN xxx ID yyyrn
Set OUTPUT xxx ID to yyy
Set OUTPUT xxx SCALE to yyy
Set OUTPUT xxx PERMISSION to
yyy Set INPUT xxx ID
to yyy
xxx: RX ID number before change, ranging from 1 to 762 yyy: RX ID number after
change, ranging from 1 to 762. Note: Only change the RX ID number, not change
IP address. xxx: RX ID number to be set, ranging from 1 to 762 yyy: SCALE mode
number, range 0~19:
0:Pass Through (default); 1:HDMI 1080p@60Hz; 2:HDMI 1080p@50Hz; 3:HDMI
1080p@30Hz; 4:HDMI 1080p@25Hz; 5:HDMI 1080p@24Hz 6:HDMI 720p@60Hz; 7:HDMI
720p@50Hz; 8:HDMI 576p@50Hz; 9:HDMI 480p@60Hz; 10:HDMI 640×480@60Hz; 11:HDMI
800×600@60Hz; 12:HDMI 1024×768@60Hz; 13:HDMI 1280×800@60Hz; 14:HDMI
1280×1024@60Hz; 15:HDMI 1366×768@60Hz; 16:HDMI 1440×900@60Hz; 17:HDMI
1600×1200@60Hz; 18:HDMI 1680×1050@60Hz; 19:HDMI 1920×1200@60Hz xxx: RX ID
number to be set yyy: Set the maximum ID number that RX can connect to TX,
ranging from 0 to 762. When yyy is 0, it means that TX with ID 1~762 can be
connected; When yyy is 1~762, it means that TX with ID 1~yyy can be connected.
xxx: TX ID number before change, ranging from 1 to 762; yyy: TX ID number
after change, ranging from 1 to 762. Note: Only change the TX ID number, not
change the IP address.
TECHNICAL
DATA
20
PRECAUTIONS
PACKAGE CONTENTS
Set TX ID xxx EDID to yyy
!IN xxx EDID yyyrn
Get MAC address
!MAC GETrn
Set INPUT xxx EDID to yyy
Get MAC xx:xx:xx:xx:xx:xx
xxx: TX ID number to be set, range 1~762 yyy: EDID serial number, range 0~7:
0: HDMI 1080p@60Hz, Audio 2CH PCM (default) 1: HDMI 720p@60Hz , Audio 2CH PCM
2: DVI 1280×1024@60Hz, Audio None 3: DVI 1920×1080@60Hz, Audio None 4: DVI
1920×1200@60Hz, Audio None 5: HDMI 1920×1200@60Hz, Audio 2CH PCM 6: User EDID
1 7: User EDID 2
Get the MAC address of current device
· Any TX can control any TXs and RXs. The following api items 1 to 7 all can
be used. · RX can only set parameters for the device connected to serial port,
and only api 1
to 4 and the api 7 can be used.
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
PANEL
FUNCTIONS
TECHNICAL
DATA
21
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
5.2.2 ADVANCED NETWORK MANAGEMENT For larger AV over IP multicast scenarios
involving several VEO-XTI1CG2 and VEOXRI1CG2 devices, it is recommended to add
a VEO-XCTRLG2 controller module in the system. This unit will allow the user
to manage and operate all the transmitters and receivers from a unique Web
interface, including Preview mode, Matrix control, Video Wall management
control or even the use of TCP commands to remotely communicate with
VEOXTI1CG2 and VEO-XRI1CG2 units present in the network. For further details
on how to set up an advanced networked installation control layout interface,
please refer to VEOXCTRLG2 controller module user manual.
22
PANEL
FUNCTIONS
TECHNICAL
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
6. PANEL FUNCTIONS
6.1 VEO-XTI1CG2 (TX, TRANSMITTER) 6.1.1 FRONT PANEL
1. POWER LED: The LED flashes when the device is power supplied and stays lid
(RED) after the start up is complete.
2. LINK LED: Network connection status LED: o Light on: Network connection is
stable and there’s a compatible video signal. o Light off: No network
connection. o Light flashing (slow): Network connection is stable but there’s
no video signal. o Light flashing (fast): Network connection is stable but
there’s no compatible video signal (resolution or frame rate are greater than
native).
3. STATUS DISPLAY: indicates current ID channel and further device
information. When clicking the “SHOW ME” option on the VEO-XCTRLG2, the status
display will flash “SHO” for an easier location of the corresponding device.
For further details, refer to Additional functionalities of CH select /
buttons for both: VEO-XTI1CG2 & VEO-XRI1CG2 chapter.
4. CH SELECT (UP/DOWN): Use these buttons to set the ID channel of the
device. It is also possible to adjust audio mode, manage EDID, consult IP
address, or enter configuration mode. For further details, refer to Additional
functionalities of CH select / buttons for both: VEO-XTI1CG2 & VEO-XRI1CG2
chapter.
5. RESET: System reset button. Pressing and holding for 5 seconds will
restart and restore factory settings on the device.
23
PANEL
FUNCTIONS
TECHNICAL
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
6.1.2 REAR PANEL
6. RS-232: Serial port for remote control. Signal pass-through supported. 7.
AUDIO IN/OUT:
o AUDIO IN: When this mode is selected, the audio port acts as an input (audio
embedding to HDMI).
o AUDIO OUT: When this mode is selected, the audio port acts as an output
(audio extraction from HDMI).
8. LAN (PoE) CONNECTOR: Connect the 1Gb network port to an Ethernet switch to
begin data transmission. When PoE on the Ethernet switch is available, the
device will not need to be locally powered.
9. LINK indication (Green): o Light ON: The network cable is correctly
connected. o Light OFF: No Network connection.
10. DATA Indicator (Yellow): o Flashing: Data transmission o Light OFF: No
Data transmission
11. HDMI IN: HDMI input port 12. DC 12V PORT: Connect this port to the 12VDC
included power supply.
24
PANEL
FUNCTIONS
TECHNICAL
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
6.2 VEO-XRI1CG2 (RX, RECEIVER) 6.2.1 FRONT PANEL
1. POWER LED: The LED flashes when the device is power supplied and stays lid
(RED) after the start up is complete.
2. LINK LED: Network connection status LED: o Light on: Network connection is
stable and there’s a compatible video signal. o Light off: No network
connection. o Light flashing (slow): Network connection is stable but there’s
no video signal. o Light flashing (fast): Network connection is stable but
there’s no compatible video signal (resolution or frame rate are greater than
native).
3. STATUS DISPLAY: indicates current ID channel and further device
information. When clicking the “SHOW ME” option on the XCTRLG2, the status
display will flash “SHO” for an easier location of the corresponding device.
For further details, refer to Additional functionalities of CH select /
buttons for both: VEO-XTI1CG2 & VEOXRI1CG2 chapter.
4. CH SELECT (UP/DOWN): Use these buttons to set the ID channel of the
device. It is also possible to adjust audio mode, manage EDID, consult IP
address, or enter configuration mode. For further details, refer to Additional
functionalities of CH select / buttons for both: VEO-XTI1CG2 & VEO-XRI1CG2
chapter.
5. RESET: System reset button. Pressing and holding for 5 seconds will
restart and restore factory settings on the device.
25
PANEL
FUNCTIONS
TECHNICAL
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
6.2.2 REAR PANEL
6. RS-232: Serial port for remote control. Signal pass-through supported. 7.
AUDIO OUT: The audio port acts as an audio de-embedder from HDMI. 8. LAN (PoE)
CONNECTOR: Connect the 1Gb network port to an Ethernet switch to
begin data transmission. When PoE on the Ethernet switch is available, the
device will not need to be locally powered. 9. LINK indication (Green):
o Light ON: The network cable is correctly connected. o Light OFF: No Network
connection. 10. DATA Indicator (Yellow): o Flashing: Data transmission. o
Light OFF: No Data transmission. 11. HDMI OUT: HDMI output port. 12. DC 12V
PORT: Connect this port to the 12VDC included power supply.
26
PANEL
FUNCTIONS
TECHNICAL
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
6.3 ADDITIONAL FUNCTIONALITIES OF CH SELECT / BUTTONS FOR BOTH: VEOXTI1CG2 AND VEO-XRI1CG2
Settings IP Address
ID
Buttons Pressed
Description
Pressing and holding the button for 5 seconds will show the
current IP address of VEO-XTI1CG2 or VEO-XRI1CG2 device in
the Status display. This message will appear following the
sequence “xxx”, “xxx”, “xxx”, “xxx”.
Pressing and holding the button for 5 seconds will show the
current IDs of VEO-XTI1CG2 or VEO-XRI1CG2 device in the
Status display. This message will appear following the sequence
“xxx”,
Wake up
or
After the system is powered on, the VEO-XTI1CG2 / VEOXRI1G2 device Status display will show the ID Channel. When idle and Display configured as OFF, pressing or button will turn on the Status display and show the current ID Channel number (e.g. 001).
Configuration
Pressing and holding and buttons together at the same time for 5 seconds will
enter the “Configuration” mode with “CFN” displaying on the status display.
Further long pressing of and buttons buttons will allow to confirm and enter
in the next configuration menu.
and Available menus are:
· ID modifying. · EDID settings. · Audio Settings. · Output Resolution
Settings (Only VEO-XRI1CG2). · Video Timeout Settings (Only VEO-XRI1CG2).
ID Settings
For VEO-XRI1C2G receivers the ID can be changed just pressing the or buttons and this allows to receive the desired streaming from the transmitter. VEO- XTI1CG2 Transmitter ID must be unique in a network so the procedure to change the ID is not so immediate.
and
Pressing and holding and buttons both together at the same time for 5 seconds will enter the “ID Settings” mode. The ID Channel will flash, then pressing the or button will select the desired ID Channel and pressing and hold and buttons once again both together at the same time for 5 seconds, will confirm the selected ID Channel and exit “ID Settings” mode and go to the next menu.
PANEL
FUNCTIONS
TECHNICAL
DATA
27
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
After showing ID settings menu, long pressing the or button until the Status display shows “E00” (in which “E” refers to EDID, “00” to EDID ID) in the Status display. Then pressing and holding and buttons both together at the same time buttons for 5 seconds will enter “EDID Settings” mode. The EDID ID number (e.g. E01) on the Status display will flash. Then pressing the or button will select the desired EDID ID:
EDID Settings (only VEO-XTI1CG2)
and
EDID ID
00 01 02 03 04 05 06 07 08
EDID Description
Video: HDMI 1080p@60Hz / Audio: Stereo PCM Video: HDMI 720p@60Hz / Audio:
Stereo PCM Video: DVI 1024p@60Hz Video: DVI 1080p@60Hz Video: DVI 1200p@60Hz
Video: HDMI 1200p@60Hz / Audio: Stereo PCM Copy from VEO-XRI1CG2 HDMI output
USER 1 USER 2
· The default EDID of 1080p60 will be used if an EDID has not previously been
copied to ID 06 or downloaded to ID 07/08 on VEO-XCTRLG2 Web GUI
· EDID ID 06/07/08 are not available without VEOXCTRLG2.
Pressing and holding and buttons both together for 5 seconds will confirm the selected EDID ID and exit “EDID Settings” mode.
Audio Settings (only VEO-XTI1CG2)
and
After showing EDID menu, long pressing or button until the Status display
shows “AHE”. Then pressing and holding and buttons both together for 5 seconds
will enter the “Audio Settings” mode. The current audio mode will appear
flashing. Pressing or button will select the desired option:
· AHE: HDMI embedded audio signal will be outputted through AUDIO OUT ports on
VEO-XTI1CG2 and VEOXRI1CG2
· AEI: External audio source signal coming in AUDIO IN on VEO-XTI1CG2 will be
outputted through AUDIO OUT port on VEO-XRI1CG2.
PANEL
FUNCTIONS
TECHNICAL
DATA
28
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
Long pressing the or button until the Status display shows “S00” (in which “S” refers to Scaler and “00” to resolution ID). Then pressing and holding and buttons both together for 5 seconds, will enter the “Output Resolution Settings” mode. The Resolution ID number (e.g. S01) on the Status display will flash. Then pressing the or button will select the desired resolution ID:
Output Resolution
Settings
and
(Only VEO-XRI1CG2)
Resolution ID 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19
Resolution Description Pass-through 1080p@60Hz 1080p@50Hz 1080p@30Hz 1080p@25Hz 1080p@24Hz 720p@60Hz 720p@50Hz 576@50Hz 480@60Hz 640×480@60Hz 800×600@60Hz 1024×768@60Hz 1280×800@60Hz 1280×1024@60Hz 1366×768@60Hz 1440×900@60Hz 1600×1200@60Hz 1680×1050@60Hz 1920×1200@60Hz
Pressing and holding and buttons both together for 5 seconds will confirm the selected Resolution ID and exit “Output Resolution Settings” mode
Video Timeout
Settings
and
(Only VEO-XRI1CG2)
Long pressing the or button until the Status display shows “H00” (in which “H” refers to HDMI TIMEOUT an “00” to the time in minutes. Then pressing and holding and buttons both together for 5 seconds, will enter the “Video Timeout Setting” mode. The number (e.g., H01) on the Status display will flash. Press the or button to select the desired time to disable the HDMI output after the VEOXTI1CG2 HDMI input doesn’t detect video signal.
PANEL
FUNCTIONS
TECHNICAL
DATA
29
7. TECHNICAL DATA
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
PRECAUTIONS
PACKAGE CONTENTS
7.1 TECHNICAL SPECIFICATIONS
VEO-XTI1CG2 / VEO-XRI1CG2
Video Performances Video Input Connector
Video Output connector Video Input Resolution
Video Output Resolution Video Codec
Transmission Latency
Chroma Subsampling Colour Depth Colour Space HDCP HDR
Video Composing Capabilities Scaling Feature HDMI Distance
Audio Performances Audio Input Connectors
Audio Output Connectors Audio Formats Sample Rate Bit Depth
Frequency Response ARC/eARC
Control Control Connectors Control Protocols Control Buttons
EDID Management Status Indicators
Pass-through Control Pass-through Connectors Pass-through Protocols
Network Network Connectors
Network Requirements Average Streaming Bitrate
Transmission Distance Electrical
Power Supply AC Mains Connector DC Mains Connector Power Consumption
Transmitter: HDMI Type A Female, 1.4, 10.2 Gbps Receiver: HDMI Type A Female,
1.4, 10.2 Gbps Up to 1920×1200 60Hz Up to 1920×1200 60Hz H.265 and H.264
<100ms compression depending on video content and transmission / network
configuration RGB4:4:4, YCbCr 4:4:4, YCbCr 4:2:2 8-bit, 10-bit, 12-bit, 16-bit
(1080p@60Hz) RGB, YCbCr 1.4 Not supported Videowall up to 9×9 Supported 15m
with Ecler VEO Cables
Transmitter: 3-pin Euroblock (Stereo Unbalanced) Receiver and Transmitter:
3-pin Euroblock (Stereo Unbalanced) LPCM 2.0CH 32/44.1/48KHz Up to 24-bit
20Hz-20KHz Not Supported
RJ-45, Euroblock Web, TCP (only with VEO-XCTRLG2), RS-232 1 x UP button 1 x
DOWN button Via front panel and Web settings POWER LED: Red; LINK LED: Green;
LCD display
Euroblock RS-232
RJ-45 IGMP Snooping Configurable via software 1- 20Mbps 100m (Ethernet
Standard)
PoE (802.3af Class 3) or External Power supply 100-240VAC 50-60Hz with EU, UK,
US, AU blades 12VDC-1A with coaxial DC connector Transmitter: 3W / Receiver:
3W
PANEL
FUNCTIONS
TECHNICAL
DATA
30
PRECAUTIONS
Physical Operating Temperature
Operating Humidity Installation Options Included Accessories
Optional Accessories Dimensions (WxHxD)
Shipping Dimensions (WxHxD)
Weight Shipping Weight Chassis Material
Finished Colour
Min. -10°C – 14°F; Max. 45°C – 113°F <90% HR Desktop, 19″ racks (1/2RU), VEO- RACK19 2x 3pins Euroblock connector 4x M3 screws 4mm 2x Mounting Ears 1x 12V PSU VEO-RACK19 95 x 21.5 x 120mm / 3.74 x 0.85 x 4.72in. (each one, TX and RX separately) 188 x 75 x 137 mm / 7.40 x 2.95 x 5.39 in. (each one, TX and RX separately) 0.3 Kg / 0,66 lb (each one, TX and RX separately) 0.7 Kg (each one, TX and RX separately) Metal Black
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
PANEL
FUNCTIONS
TECHNICAL
DATA
31
7.2 MECHANICAL DIAGRAM 7.2.1 VEO-XTI1CG2 7.2.2 VEO-XRI1CG2
3 2
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
PANEL
TECHNICAL
FUNCTIONS
DATA
PRECAUTIONS
PACKAGE CONTENTS
DESCRIPTION &
FEATURES
INSTALL &
CONNECT
START-UP &
OPERATION
PANEL
FUNCTIONS
TECHNICAL
DATA
All product characteristics are subject to variation due to production tolerances. NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications.
For technical queries contact your supplier, distributor or complete the contact form on our website, in Support / Technical requests.
Motors, 166-168 -08038 Barcelona – Spain-(+34) 932238403 | information@ecler.com | www.ecler.com
33
Read User Manual Online (PDF format)