Hunter Pro C Manual Start: User Guide for Irrigation Controller
- June 2, 2024
- Hunter
Table of Contents
The Hunter Pro C Manual Start User Guide for Irrigation Controller is a comprehensive guide that provides detailed information on the Hunter Pro C irrigation controller. This guide is designed to help users understand the specifications and electrical requirements of the Hunter Pro C controller, as well as its various features and functions. The Hunter Pro C is a modular controller that can be used for both residential and light commercial applications, and it comes in both indoor and outdoor models. The guide provides information on the controller’s operating specifications, including station run time, start times, and watering schedules. It also includes details on the electrical specifications of the controller, such as transformer input and output, station output, and battery requirements. Additionally, the guide provides information on the default settings of the controller, as well as cleaning instructions and frequently asked questions. Overall, the Hunter Pro C Manual Start User Guide is an essential resource for anyone who wants to get the most out of their Hunter Pro C irrigation controller.
Hunter Pro C
Hunter Residential and Light Commercial Irrigation Controller
PC Series
Modular Controller
Indoor/Outdoor Models
SPECIFICATIONS
Operating Specifications
- Station Run Time: 1 minute to 6 hours on programs A, B, and C
- Start Times: 4 per program, three programs for up to 12 starts
- Watering Schedule: 7-day calendar, interval watering up to a 31-day interval or true odd or even day programming, made possible by the 365-day clock/calendar
Electrical Specifications
- Transformer Input: 120 VAC, 60 hz (230 VAC, 50/60 hz International Use)
- Transformer Output: 24 VAC, 1 amp
- Station Output: 24 VAC, 0.56 amps per station
- Maximum Output: 24 VAC, 0.84 amps (includes Master Valve Circuit)
- Battery: 9-volt alkaline battery (not included) used only for non-AC programming, the non-volatile memory maintains program information
- Battery, front panel, internal CR2032 lithium for real-time clock
Cabinet Dimensions
Height: 9″ (23 cm)
Width: 10″ (21.5 cm)
Depth: 4.5″ (10.9 cm)
Outdoor cabinet is NEMA 3R, IP44 rated.
Default Settings
All stations are set to zero run time. This controller has a non-volatile
memory that retains all entered program data even during power outages,
without need for a battery.
Cleaning
Clean only with cloth dampened with mild soapy water.
PRO-C COMPONENTS
Questions about your Manual? Post in the comments!
Hunter Pro-C PC Series Mdular Controller Owner’s Manual and Installation
Instructions – Original PDF
Hunter Pro-C PC Series Modular Controller Owner’s Manual and Installation
Instructions – Original PDF
Hunter Pro-C Light Commercial Irrigation Controllers Owner’s Manual and
Installation Instructions – Original PDF
Specifications
Controller Type | Hunter Residential and Light Commercial Irrigation Controller |
---|---|
Series | PC Series |
Modular Controller | Yes |
Indoor/Outdoor Models | Yes |
Station Run Time | 1 minute to 6 hours on programs A, B, and C |
Start Times | 4 per program, three programs for up to 12 starts |
Watering Schedule | 7-day calendar, interval watering up to a 31-day interval |
or true odd or even day programming, made possible by the 365-day
clock/calendar
Transformer Input| 120 VAC, 60 hz (230 VAC, 50/60 hz International Use)
Transformer Output| 24 VAC, 1 amp
Station Output| 24 VAC, 0.56 amps per station
Maximum Output| 24 VAC, 0.84 amps (includes Master Valve Circuit)
Battery| 9-volt alkaline battery (not included) used only for non-AC
programming, the non-volatile memory maintains program information. Front
panel, internal CR2032 lithium for real-time clock
Cabinet Dimensions| Height: 9″ (23 cm) Width: 10″ (21.5 cm) Depth: 4.5″ (10.9
cm). Outdoor cabinet is NEMA 3R, IP44 rated.
Default Settings| All stations are set to zero run time. This controller has a
non-volatile memory that retains all entered program data even during power
outages, without need for a battery.
FAQs
Do you need to reset the unit if the house loses electricity?
Yes you have to reset the box again
Does this include the 4 zone module?
Yes. The base model controls 4 zones. Add up to 3 more 4 station modules to control up to 16 zones!
what is the difference between hunter model pc-400 vs pc-400i?
I’m not real familiar with the 400, but the 400i can be expanded to 16 zones with added snap in modules.
What is Hunter Warranty on this product?
2 Years.
Can I add a remote to the 400i?
Yes, it works with the ROAM remote system.
What is input output voltage?
Input 120 VAC, output 24 VAC
Does this model have a delay function?
If u are talking about a timer function – yes it does
Can this controller be plugged into a wall outlet or does it need to be hard wired?
Yes. It should come with an AC adapter. The outdoor model needs to be either hard wired or you can strip a grounded extension cord and wire it that way.
Can this unit be programmed for intervals — such as watering every 10 days or however many you want?
You can program the unit to run daily or only on specific days of the week.
Once every 7 day
Is the longest interval. You can download the operators manual from the Hunter
website
Does it come with modules? If so, what configuration?
This is the base unit only, with no expansion modules. The base unit can control 4 zones.
Is this compatible with hunter src?
Yes, this is a great replacement for the SRC timer.
What are the operating specifications of the Hunter Pro C irrigation controller?
The station run time is 1 minute to 6 hours on programs A, B, and C. The start times are 4 per program, three programs for up to 12 starts. The watering schedule is a 7-day calendar, interval watering up to a 31-day interval or true odd or even day programming, made possible by the 365-day clock/calendar.
What are the electrical specifications of the Hunter Pro C irrigation controller?
The transformer input is 120 VAC, 60 hz (230 VAC, 50/60 hz International Use). The transformer output is 24 VAC, 1 amp. The station output is 24 VAC, 0.56 amps per station. The maximum output is 24 VAC, 0.84 amps (includes Master Valve Circuit). The battery required is a 9-volt alkaline battery (not included) used only for non-AC programming, the non-volatile memory maintains program information. The battery for the front panel is an internal CR2032 lithium for real-time clock.
What are the dimensions of the Hunter Pro C irrigation controller cabinet?
The height is 9″ (23 cm), width is 10″ (21.5 cm), and depth is 4.5″ (10.9 cm). The outdoor cabinet is NEMA 3R, IP44 rated.
Video