STIEBEL ELTRON MAE Non-Pressurised Tap for Mini Instantaneous Water Heater Instruction Manual

June 3, 2024
STIEBEL ELTRON

STIEBEL ELTRON MAE Non-Pressurised Tap for Mini Instantaneous Water Heater

General information

The chapter “Operation” is intended for appliance users and qualified contractors.
The chapter “Installation” is intended for qualified contractors.

| Note
Read these instructions carefully before using the appliance and retain them for future reference.
Pass on the instructions to any new user if required
---|---

Safety instructions

Structure of safety instructions

| KEYWORD Type of risk
Here, possible consequences are listed that may result from failure to observe the safety instructions.
• Steps to prevent the risk are listed.
---|---

Symbols, type of risk

Symbol Type of risk
Burns (burns, scalding)

Keywords

KEYWORD

|

Meaning

---|---
DANGER| Failure to observe this information will result in serious injury or death.
WARNING| Failure to observe this information may result in serious injury or death.
CAUTION| Failure to observe this information may result in non-serious or minor injury.

Other symbols in this documentation

| Note
General information is identified by the adjacent symbol.
• Read these texts carefully.
---|---

Symbol

|

Meaning

---|---
| Material losses
(appliance damage, consequential losses and environmental pollution)
| Appliance disposal

  • This symbol indicates that you have to do something. The action you need to take is described step by step.
Units of measurement

| Note
All measurements are given in mm unless stated otherwise.
---|---

Safety

Intended use

This product is intended for operation with an open vented (non-pressurised) mini instantaneous water heater.
This product is designed for domestic use. It can be used safely by untrained persons. The appliance can also be used in a non-domestic environment, e.g. in a small business, as long as it is used in the same way.
Any other use beyond that described shall be deemed inappropriate. Observation of these instructions is also part of the correct use of this appliance.

General safety instructions

| WARNING Burns
During operation, the tap can reach temperatures in excess of 60 °C.
There is a risk of scalding at outlet temperatures in excess of 43 °C.
---|---
| Material losses
Whilst the water in the instantaneous water heater is being heated, expansion water will drip from the spout. Scale build-up can block the spout and thus subject the instantaneous water heater to pressure.
• Never block the spout and only use the original aerator
---|---

Operation

MAE

To draw water, lift the lever.
To achieve the required temperature, mix the cold and hot water by moving the lever sideways.

MAZ
  1. Swivelling spout
  2. Aerator inside the fitting
  3. Draw-off valve cold
  4. Draw-off valve hot
MAW
  1. Draw-off valve hot
  2. Swivelling spout
  3. Aerator inside the fitting
  4. Draw-off valve cold

Cleaning and care

  • Never use abrasive or corrosive cleaning agents. A damp cloth is sufficient for cleaning and caring for the product.
  • For descaling, remove the aerator from the fitting.

Safety

Only qualified contractors should carry out installation, commissioning as well as maintenance and repair of the product.

General safety instructions

We guarantee trouble-free function and operational reliability only if original accessories and spare parts intended for the product are used.

Instructions, standards and regulations

| Note
Observe all applicable national and regional regulations and instructions.
---|---

Installation

MAE
  1. Aerator inside the fitting (spanner size 22)
  2. U-shaped profile washer
  3. U-shaped pressure washer
  4. Drain cup
  5. Gasket
  6. Profile gasket
  7. Drain outlet
  8. Spring sleeve (spanner size 13)
  9. Fitting G 3/8
  10. Knuckle joint
  11. Seal ring
  12. Pull rod
  • Insert the tap with seal ring.
  • Secure the tap from below with a U-shaped profile washer, U-shaped pressure washer and spring sleeve.
  • Unscrew the drain funnel from the tundish.
  • Insert the drain cup with the gasket from above.
  • Secure the drain outlet with the profile gasket from below.
  • Insert the pull rod into the tap body.
  • Secure the pull rod and connect it to the knuckle joint with the drain trim.
MAZ
  1. Aerator inside the fitting (spanner size 22)
  2. Spout fitting (spanner size 30)
  3. Fitting G 3/8
  4. Seal ring
  5. Spacer
  6. U-shaped profile washer
  7. U-shaped pressure washer
  8. Spring sleeve (spanner size 13)
  • Insert the tap with seal ring.
  • Secure the tap from below with a U-shaped profile washer, U-shaped pressure washer and spring sleeve.
  • Fit the spout to the tap body.
MAW
  1. Fitting G 3/8
  2. Spout fitting (spanner size 24)
  3. Wall cover bezel
  • Turn in tap with the wall collar.
  • Connect the spout to the tap body.
Water connection

| Note
Ensure that the connection hoses are not kinked, turned or interchanged during installation. Prevent any tensioning during installation.
---|---

  • Please note that, depending on the supply pressure, you may also need a pressure reducing valve.
MAE | MAZ

Diagram MAE

  • Connect the short connection hose marked blue to the angle valve of the cold water supply line.
  • Connect the long connection hose marked blue to the “Cold water inlet” connection on the instantaneous water heater.
  • Connect the long connection hose marked red to the “DHW outlet” connection on the instantaneous water heater.
  • Test the tap and connection hoses for tightness.

Initial start-up

  • Thoroughly flush the cold water supply line.
  • Fill the instantaneous water heater by drawing off the tap several times until the pipework and instantaneous water heater are free of air.
  • Carry out a tightness check.
  • Connect the mains power of the instantaneous water heater

Specification

Dimensions and connections

MAE

MAZ

MAW

Data table

| | MAE| MAZ| MAW
---|---|---|---|---
| | 185476| 185475| 185474
Application| | Washbasin| Washbasin| Washbasin
Type| | Open| Open| Open
Type of installation| | Monobloc mixer tap| Monobloc mixer tap| Wall mounted mixer
Connection| | G 1/2 A
Connection| | Connecting hoses| Connecting hoses| Connecting hoses
Spout height| mm| 43| 170|
Reach| Mm| 113| 150| 160
Test pressure| MPa| 1.6| 1.6| 1.6
Flow rate| l/min| 3.5| 3.5| 3.5
Max. operating temperature| °C| 90| 90| 90

Guarantee

The guarantee conditions of our German companies do not apply to appliances acquired outside of Germany. In countries where our subsidiaries sell our products a guarantee can only be issued by those subsidiaries. Such guarantee is only granted if the subsidiary has issued its own terms of guarantee. No other guarantee will be granted.
We shall not provide any guarantee for appliances acquired in countries where we have no subsidiary to sell our products. This will not affect warranties issued by any importers.

Environment and recycling

We would ask you to help protect the environment. After use, dispose of the various materials in accordance with national regulations.

United States of America
STIEBEL ELTRON, Inc.
17 West Street | 01088 West Hatfield MA
Tel. 0413 247-3380 | Fax 0413 247-3369
info@stiebel-eltron-usa.com
www.stiebel-eltron-usa.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

STIEBEL ELTRON User Manuals

Related Manuals