HYGENIQ Clean Air Fogger Machine User Manual

June 6, 2024
Hygeniq

USER MANUAL
HYGENIC Clean Air Fogger
Effortless 360° cleaning

Model: HYGIENIC CLEAN AIR FOGGER1.0
Product code: E150004
Date: 11/12/2020 Version: B

HYGENIQ
Lenteweg 15, 7532 RV Enschede, The Netherlands
+31(0)53 428 28 60
info@hygeniq.com
www.hygeniq.com

PREFACE

Thank you for purchasing the HYGENIC CLEAN AIR FOGGER1.0. The powerful easy- to-use system can remove the negative effect from the air in seconds. It also makes cleaning surfaces much more effective when combined with the approved HYGIENIC CLEAN AIR Mist. Due to the 24V Li-ion battery and refillable tank, you can keep cleaning for as long as you wish. Please read the user manual carefully and become familiar with the operation and maintenance procedures. Store the manual in a safe place.

Packing List

Safety Instructions

The following symbols and terms are used throughout this manual and on the machine to alert the reader to safety issues and important information:

Symbol Term Explanation
WARNING

Indicates a hazardous situation which, if the safety instructions are not followed, can lead to injuries of the operator or bystanders, light and/or moderate damage to the product or the environment.

STRONG MAGNET| This indicates the machine contains strong magnets. These can cause pacemakers to stop as well as cause damage to electronic data, for instance on information stored on access passes.
PACEMAKER| Indicates operators and maintenance crew wearing pacemakers should keep a minimum distance of 6 inches/ 15 cm. In this specific case, operators may not use the machine as a backpack.
BATTERIES|

Indicates a battery-operated machine. Batteries must be disposed of according to your local laws and regulations. It is advisable to fully charge the battery before use.

Read all instructions before using HYGIENIC CLEAN AIR FOGGER
Cautions when using the machine:

Do not operate the machine without reading and fully understanding the instructions. If the machine is operated incorrectly it can pose a danger to the operator and others and will invalidate the manufactures warranty.

Before use please read and understand the following:

  • A risk assessment for the works to be undertaken;
  • MSDS Chemical Datasheet;
  • Risk assessment for chemical use.

Keep the HYGENIC CLEAN AIR FOGGER upright and securely fastened at all times while in use and during preparation and transportation.

Only use approved HYGIENIC CLEAN AIR Mist and batteries for safe use of this machine. Using other consumable items in the fogger invalidates the warranty and could lead to damage of the internal parts and could possibly pose a risk to the operator.

Maintenance/service people and operators with pacemakers need to keep a distance from the integrated magnets in the HYGENIC CLEAN AIR FOGGER of 6 inches/15 cm whilst maintaining and operating the fogger.

Make sure the operator has been fully trained before using the machine.

Avoid fogging directly on humans and animals.

Ensure the machine is used in a dry environment, and do not allow water or any other liquid around the motor air inlet.

Product Description

Item Specification
Product weight (W/O battery) 7.9KG
Product dimension Main body: 200x595x225mm Included harness: 300x600x315mm
Tank capacity 3.5L
Battery weight 1.3KG
Battery voltage DC24V
Duration of battery 1 Hour
Charger input voltage AC100-250 Voltage
Charging time 1 Hour 50 minutes
Speed of spray 175-100m1/minutes
Hose length 1.2 meters
Droplet size 20-150pm
Spray nozzles 3 x 0.3mm, 0.5mm, 0.8mm, 1.0mm
Theoretical capacity per tank 12000m3
Machine power 450W
Spray distance 5-6 meters
Pump DC24V, 5W, 100m1/minute
Main body material LDPE
Spray handle material Aluminum

The switch on the spray handle does not have a self-locking trigger button. When you press it once, the spray nozzle starts to fog. When you press it again, the fogging will stop. When the operator forgets to press the button to stop fogging and turns off the machine with the power switch, the fogging will also stop. However, this is not recommended. Upon restarting the fogger, the default setting of the spray nozzle is off.

Setup

  1. Charging the battery
    For first-time charges, please remove the yellow protector from the battery. Ensure that the battery has been fully charged before each operation.

  2. Fill the liquid tank
    Place and secure the machine body upright. Unscrew the cap of the liquid tank, and pour the approved HYGIENIC CLEAN AIR Mist into the tank.
    Or
    Take the liquid tank from the machine, and secure it in an upright position. Unscrew the cap of the liquid tank, and pour the required amount of the approved HYGIENIC CLEAN AIR Mist into the tank. Insert the liquid tank back into the machine which should also be placed in an upright position. Note: 1L of HYGIENIC CLEAN AIR Mist covers approximately 3650 m3.

  3. Insert the battery into the machine
    Open the battery housing door, and slide the fully charged battery into the battery housing, until you hear a “click” sound. Make sure the battery is installed correctly and then close the door. To remove the battery, use the clamps on the sides of the battery to release.

  4. Installation of the nozzle in spray handle
    Select the appropriate nozzle for the application. Nozzle size| Droplet size| Spray distance| Duration (3.5L)| Application
    ---|---|---|---|---
    3 × 0.3mm| ∼20 pm| 5∼6m| 35minutes| indoor
    0.5mm| ∼30pm| 5∼6m| 30minutes| indoor
    0.8mm| ∼40pm| 5∼6m| 25∼30minutes| indoor
    1.0mm| ∼60pm| 5∼6m| 20∼25minutes| outdoor

Operation

  1. Place the machine body with a filled tank on the table, and then place the spray nozzle on the lower hook.

  2. Turn the main switch to “on” before placing the fogger on your back and adjust the straps and the belt to the most optimal/comfortable operating position.

  3. Spraying steps

  4. Additional information:

Preferably disperse the mist through the room as high as possible for an optimal effect. This is especially recommended for larger areas/rooms. The mist droplets agglomerate effectively with unwanted substances in the air, which then sink down and can no longer be inhaled. During this process, an invisible screen is created that purifies the air from top to bottom.

HYGIENIC CLEAN AIR MIST can also be used to clean surfaces. Wipe clean the surfaces after spraying of the mist on the targeted objects. Specific ‘risk points’ such as door handles, light switches, and other touchpoints or contact surfaces can be targeted directly to ensure optimal hygiene. Use MIST regularly for optimal
hygienic results.

Maintenance

The fogger needs to be maintained during normal use:

  1. Empty the liquid tank after each use, and rinse the tank and the hose with clean water;

  2. Charge the battery fully after each use;

  3. It is best not to exceed 4 hours of continuous use;

  4. Ensure the machine is always used upright and in a dry environment, and do not allow water or any other liquid around the motor air inlet.

  5. Spray nozzles need to be stored in the small toolbox, together with the screwdriver. The toolbox can be hooked on to the backpack harness spring hook (3 nozzles in the toolbox and 1 in the spray handle).

  6. If there is an issue with your fogger please contact HYGENIC.