Hygeniq Fogger Machine User Manual
- June 2, 2024
- Hygeniq
Table of Contents
USER MANUAL
HYGENIQ FOGGER
Model: HYGENIQ FOGGER1.0
Product code: E150004
Date: 17/09/2020
Version: A
HYGENIQ
Lenteweg 15, 7532 RV Enschede, The Netherlands
+31(0)53 428 28 60
info@hygeniq.com
www.hygeniq.com
PREFACE
Thank you for purchasing the HYGENIQ FOGGER1.0. The powerful easy to use system that can remove the dangerous particles from the air in seconds. It also makes disinfecting surfaces much more effective when combined with the approved HYGENIQ Mist. Due to the 24V Li-ion battery and refillable tank, you can keep disinfecting for as long as you wish. Please read the user manual carefully and become familiar with the operation and maintenance procedures. Store the manual in a safe place.
Packing List
Safety Instructions
The following symbols and terms are used throughout this manual and on the machine to alert the reader to safety issues and important information:
Read all instructions before using HYGENIQ FOGGER
Cautions when using the machine:
Do not operate the machine without reading and understanding the instructions. If the machine is operated incorrectly it can pose danger to the operator and others and will invalidate the manufactures warranty.
Please understand the followings:
• A risk assessment for the works to be undertaken;
• MSDS Chemical Data sheet;
• Risk assessment for chemical use.
Keep the machine body upright and securely fastened at all times while using HYGENIQ FOGGER, during preparation and transportation.
Only use approved HYGENIQ Mist and batteries for safe use of the machine. Using other consumable items in the machine invalidates the warranty and will lead to damage of the internal parts of the machine and could possibly pose a risk to operator.
Maintenance/service people and operators with pacemaker need to keep a distance to the integrated magnets in HYGENIQ FOGGER of 6 inch/15 cm when they are doing maintenance on and operating FOGGER.
Make sure the operator has been fully trained before using the machine.
Avoid spray directly on humans and animals.
Ensure the machine is used in a dry environment, and don not allow water or any other liquid around the motor air inlet.
Product Description
Setup
1. Charge the battery
Ensure that the battery has been fully charged before each operation. Before
charging the battery for the first time, please read the instruction manual of
battery charger.
2. Fill the liquid tank
Place and secure the machine body upright. Unscrew the cap off the liquid
tank, and pour the approved HYGENIQ Mist into the tank.
Or
Take off the liquid tank from the machine, and place and secure it in a
upright position. Unscrew the cap off the liquid tank, and pour the approved
HYGENIQ Mist into the tank. Insert the liquid tank back to the machine which
should also be placed in an upright position.
3. Insert the battery to the machine
Open the door of battery housing, and sliding one fully charged battery into
the battery housing, until you hear a “click” sound. Make sure the battery is
installed correctly and then close the door.
To remove the battery, use the clamps on the sides of the battery to release.
4. Installation of the nozzle in spray handle
Select the appropriate nozzle for the application.
Operation
1. Place the machine body on the table, and then place the spray nozzle on the lower hook.
2. Place the machine on the back and adjust the straps and the belt to for an optimal/comfortable operating position.
3. Spraying steps
4. Additional information:
For larger spaces / rooms one should fog the higher part of the room. The Mist will agglomerate with the particles present where the antimicrobial effect will do its job. Secondary effect is that the particles get heavier and via laws of Gravity descend. This way the descending layer of mist works as a membrane filtering all other unwanted particles (such as microdust) out. This results in a completely antibacterial filtered and purified air composition in the room.
Specific ‘risk-points’ like door handles, light switches and other manual touch points can be targeted directly to ensure a sanitized surface.
Maintenance
The fogger needs to be maintained during normal use:
1. Empty the liquid tank after each use, and rinse the liquid tank and the
hose with clean water;
2. Charge the battery fully after each use;
3. It is the best not to exceed 4 hours for each continuous use;
4. Ensure the machine is always used upright and in a dry environment, and do
not allow water or any other liquid around the motor air inlet.
5. Spray nozzles need to be stored in the small tool box, together with the screw driver. The tool box can be hooked on to the backpack harness spring hook (3 nozzles in the tool box and 1 in the spray handle).
6. If there is any issue with your fogger please contact HYGENIQ.